scholarly journals Magnetomicrometry

2021 ◽  
Vol 6 (57) ◽  
pp. eabg0656
Author(s):  
C. R. Taylor ◽  
S. S. Srinivasan ◽  
S. H. Yeon ◽  
M. K. O’Donnell ◽  
T. J. Roberts ◽  
...  

We live in an era of wearable sensing, where our movement through the world can be continuously monitored by devices. Yet, we lack a portable sensor that can continuously monitor muscle, tendon, and bone motion, allowing us to monitor performance, deliver targeted rehabilitation, and provide intuitive, reflexive control over prostheses and exoskeletons. Here, we introduce a sensing modality, magnetomicrometry, that uses the relative positions of implanted magnetic beads to enable wireless tracking of tissue length changes. We demonstrate real-time muscle length tracking in an in vivo turkey model via chronically implanted magnetic beads while investigating accuracy, biocompatibility, and long-term implant stability. We anticipate that this tool will lay the groundwork for volitional control over wearable robots via real-time tracking of muscle lengths and speeds. Further, to inform future biomimetic control strategies, magnetomicrometry may also be used in the in vivo tracking of biological tissues to elucidate biomechanical principles of animal and human movement.

1990 ◽  
Vol 68 (1) ◽  
pp. 209-219 ◽  
Author(s):  
M. Okazawa ◽  
P. Pare ◽  
J. Road

We applied the technique of sonomicrometry to directly measure length changes of the trachealis muscle in vivo. Pairs of small 1-mm piezoelectric transducers were placed in parallel with the muscle fibers in the posterior tracheal wall in seven anesthetized dogs. Length changes were recorded during mechanical ventilation and during complete pressure-volume curves of the lung. The trachealis muscle showed spontaneous fluctuations in base-line length that disappeared after vagotomy. Before vagotomy passive pressure-length curves showed marked hysteresis and length changed by 18.5 +/- 13.2% (SD) resting length at functional residual capacity (LFRC) from FRC to total lung capacity (TLC) and by 28.2 +/- 16.2% LFRC from FRC to residual volume (RV). After vagotomy hysteresis decreased considerably and length now changed by 10.4 +/- 3.7% LFRC from FRC to TLC and by 32.5 +/- 14.6% LFRC from FRC to RV. Bilateral supramaximal vagal stimulation produced a mean maximal active shortening of 28.8 +/- 14.2% resting length at any lung volume (LR) and shortening decreased at lengths above FRC. The mean maximal velocity of shortening was 4.2 +/- 3.9% LR.S-1. We conclude that sonomicrometry may be used to record smooth muscle length in vivo. Vagal tone strongly influences passive length change. In vivo active shortening and velocity of shortening are less than in vitro, implying that there are significant loads impeding shortening in vivo.


2021 ◽  
Author(s):  
Luis G. Rosa ◽  
Jonathan S. Zia ◽  
Omer T. Inan ◽  
Gregory S. Sawicki

AbstractBackground and objectiveDynamic muscle fascicle length measurements through B-mode ultrasound have become popular for the non-invasive physiological insights they provide regarding musculoskeletal structure-function. However, current practices typically require time consuming post-processing to track muscle length changes from B-mode images. A real-time measurement tool would not only save processing time but would also help pave the way toward closed-loop applications based on feedback signals driven by in vivo muscle length change patterns. In this paper, we benchmark an approach that combines traditional machine learning (ML) models with B-mode ultrasound recordings to obtain muscle fascicle length changes in real-time. To gauge the utility of this framework for ‘in-the-loop’ applications, we evaluate accuracy of the extracted muscle length change signals against time-series’ derived from a standard, post-hoc automated tracking algorithm.MethodsWe collected B-mode ultrasound data from the soleus muscle of six participants performing five defined ankle motion tasks: (a) seated, constrained ankle plantarflexion, (b) seated, free ankle dorsi/plantarflexion, (c) weight-bearing, calf raises (d) walking, and then a (e) mix. We trained machine learning (ML) models by pairing muscle fascicle lengths obtained from standardized automated tracking software (UltraTrack) with the respective B-mode ultrasound image input to the tracker, frame-by-frame. Then we conducted hyperparameter optimizations for five different ML models using a grid search to find the best performing parameters for a combination of high correlation and low RMSE between ML and UltraTrack processed muscle fascicle length trajectories. Finally, using the global best model/hyperparameter settings, we comprehensively evaluated training-testing outcomes within subject (i.e., train and test on same subject), cross subject (i.e., train on one subject, test on another) and within/direct cross task (i.e., train and test on same subject, but different task).ResultsSupport vector machine (SVM) was the best performing model with an average r = 0.70 ±0.34 and average RMSE = 2.86 ±2.55 mm across all direct training conditions and average r = 0.65 ±0.35 and average RMSE = 3.28 ±2.64 mm when optimized for all cross-participant conditions. Comparisons between ML vs. UltraTrack (i.e., ground truth) tracked muscle fascicle length versus time data indicated that ML tracked images reliably capture the salient qualitative features in ground truth length change data, even when correlation values are on the lower end. Furthermore, in the direct training, calf raises condition, which is most comparable to previous studies validating automated tracking performance during isolated contractions on a dynamometer, our ML approach yielded 0.90 average correlation, in line with other accepted tracking methods in the field.ConclusionsBy combining B-mode ultrasound and classical ML models, we demonstrate it is possible to achieve real-time tracking of human soleus muscle fascicles across a number of functionally relevant contractile conditions. This novel sensing modality paves the way for muscle physiology in-the-loop applications that could be used to modify gait via biofeedback or unlock novel wearable device control techniques that could enable restored or augmented locomotion performance.


1996 ◽  
Vol 199 (2) ◽  
pp. 459-463 ◽  
Author(s):  
D J Coughlin ◽  
L Valdes ◽  
L C Rome

Recent attempts to determine how fish muscles are used to power swimming have employed the work loop technique (driving isolated muscles using their in vivo strain and stimulation pattern). These muscle strains have in turn been determined from the anatomical high-speed cine technique. In this study, we used an independent technique, sonomicrometry, to attempt to verify these strain measurements and the conclusions based on them. We found that the strain records measured from sonomicrometry and the anatomical-cine techniques were very similar. The ratio of the strain measured from sonomicrometry to that from the anatomical-cine technique was remarkably close to unity (1.046 +/- 0.013, mean +/- S.E.M., N = 15, for transducers placed on the muscle surface and corrected for muscle depth, and 0.921 +/- 0.028, N = 8, in cases where the transducers were inserted to the average depth of the red muscle). These measurements also showed that red muscle shortening occurs simultaneously with local backbone curvature, unlike previous results which suggested that white muscle shortening during the escape response occurs prior to the change in local backbone curvature.


1993 ◽  
Vol 183 (1) ◽  
pp. 101-113 ◽  
Author(s):  
K. M. Gilmour ◽  
C. P. Ellington

The amplitude and time course of muscle length changes were examined in vivo in tethered, flying bumblebees Bombus lucorum. A ‘window’ was cut in the dorsal cuticle and aluminium particles were placed on the exposed dorsal longitudinal muscle fibres. Muscle oscillations were recorded using high-speed video and a high-magnification lens. The amplitude of muscle length changes was 1.9 % (s.d.=0.5 %, N=7), corresponding to the commonly quoted strain of 1–3 % for asynchronous muscle. Higher harmonics, particularly the second, were found in the muscle oscillations and in the wing movements. The second harmonic for wing movements was damped in comparison to that for muscle length changes, probably as a result of compliance in the thoracic linkage. Inclusion of the second harmonic in the driving signal for in vitro experiments on glycerinated fibres generally resulted in a decrease in the work and power, but a substantial increase was found for some fibres.


PLoS ONE ◽  
2021 ◽  
Vol 16 (5) ◽  
pp. e0246611
Author(s):  
Luis G. Rosa ◽  
Jonathan S. Zia ◽  
Omer T. Inan ◽  
Gregory S. Sawicki

Background and objective Dynamic muscle fascicle length measurements through B-mode ultrasound have become popular for the non-invasive physiological insights they provide regarding musculoskeletal structure-function. However, current practices typically require time consuming post-processing to track muscle length changes from B-mode images. A real-time measurement tool would not only save processing time but would also help pave the way toward closed-loop applications based on feedback signals driven by in vivo muscle length change patterns. In this paper, we benchmark an approach that combines traditional machine learning (ML) models with B-mode ultrasound recordings to obtain muscle fascicle length changes in real-time. To gauge the utility of this framework for ‘in-the-loop’ applications, we evaluate accuracy of the extracted muscle length change signals against time-series’ derived from a standard, post-hoc automated tracking algorithm. Methods We collected B-mode ultrasound data from the soleus muscle of six participants performing five defined ankle motion tasks: (a) seated, constrained ankle plantarflexion, (b) seated, free ankle dorsi/plantarflexion, (c) weight-bearing, calf raises (d) walking, and then a (e) mix. We trained machine learning (ML) models by pairing muscle fascicle lengths obtained from standardized automated tracking software (UltraTrack) with the respective B-mode ultrasound image input to the tracker, frame-by-frame. Then we conducted hyperparameter optimizations for five different ML models using a grid search to find the best performing parameters for a combination of high correlation and low RMSE between ML and UltraTrack processed muscle fascicle length trajectories. Finally, using the global best model/hyperparameter settings, we comprehensively evaluated training-testing outcomes within subject (i.e., train and test on same subject), cross subject (i.e., train on one subject, test on another) and within/direct cross task (i.e., train and test on same subject, but different task). Results Support vector machine (SVM) was the best performing model with an average r = 0.70 ±0.34 and average RMSE = 2.86 ±2.55 mm across all direct training conditions and average r = 0.65 ±0.35 and average RMSE = 3.28 ±2.64 mm when optimized for all cross-participant conditions. Comparisons between ML vs. UltraTrack (i.e., ground truth) tracked muscle fascicle length versus time data indicated that ML tracked images reliably capture the salient qualitative features in ground truth length change data, even when correlation values are on the lower end. Furthermore, in the direct training, calf raises condition, which is most comparable to previous studies validating automated tracking performance during isolated contractions on a dynamometer, our ML approach yielded 0.90 average correlation, in line with other accepted tracking methods in the field. Conclusions By combining B-mode ultrasound and classical ML models, we demonstrate it is possible to achieve real-time tracking of human soleus muscle fascicles across a number of functionally relevant contractile conditions. This novel sensing modality paves the way for muscle physiology in-the-loop applications that could be used to modify gait via biofeedback or unlock novel wearable device control techniques that could enable restored or augmented locomotion performance.


Micromachines ◽  
2019 ◽  
Vol 10 (12) ◽  
pp. 820
Author(s):  
He Leng ◽  
Yuhling Wang ◽  
De-Fu Jhang ◽  
Tsung-Sheng Chu ◽  
Chia-Hui Tsao ◽  
...  

Photoacoustic (PA) imaging is an attractive technology for imaging biological tissues because it can capture both functional and structural information with satisfactory spatial resolution. Current commercially available PA imaging systems are limited by their bulky size or inflexible user interface. We present a new handheld real-time ultrasound/photoacoustic imaging system (HARP) consisting of a detachable, high-numerical-aperture (NA) fiber bundle-based illumination system integrated with an array-based ultrasound (US) transducer and a data acquisition platform. In this system, different PA probes can be used for different imaging applications by switching the transducers and the corresponding jackets to combine the fiber pads and transducer into a single probe. The intuitive user interface is a completely programmable MATLAB-based platform. In vitro phantom experiments were conducted to test the imaging performance of the developed PA system. Furthermore, we demonstrated (1) in vivo brain vasculature imaging, (2) in vivo imaging of real-time stimulus-evoked cortical hemodynamic changes during forepaw electrical stimulation, and (3) in vivo imaging of real-time cerebral pharmacokinetics in rats using the developed PA system. The overall purpose of this design concept for a customizable US/PA imaging system is to help overcome the diverse challenges faced by medical researchers performing both preclinical and clinical PA studies.


2019 ◽  
Vol 12 (1) ◽  
Author(s):  
Soyoun Hwang ◽  
Rohana P. Dassanayake ◽  
Eric M. Nicholson

Abstract Objective Scrapie is a transmissible spongiform encephalopathy (TSE) that naturally occurs in sheep and goats. This fatal neurodegenerative disease results from misfolding of the normal cellular prion protein (PrPC) to a pathogenic prion protein form (PrPSc). This pathogenic form, PrPSc, accumulates in the brain and lymphoid tissues. The presence of PrPSc can be detected by an in vitro conversion assay known as real-time quaking induced conversion (RT-QuIC). RT-QuIC has been used to detect PrPSc in a variety of biological tissues from brains to fluids. While this technique is both rapid and sensitive, enhancing the detection of prions would be valuable in the diagnostic laboratories. Results In this study, we assessed whether PrPSc detection sensitivity of RT-QuIC can be increased by enriching PrPSc in scrapie tissue homogenates using commercially available aggregated protein binding ligands coated magnetic beads (PAD-Beads). Coupling of RT-QuIC to PAD-Beads based cleanup allowed detection of PrPSc rapidly and without dilution of scrapie sheep brain homogenates prior to RT-QuIC. The PAD-Beads sample pretreatment step prior to RT-QuIC is a useful enhancement in the diagnosis of TSEs.


Author(s):  
Fabien Courreges ◽  
Med Amine Laribi ◽  
Marc Arsicault ◽  
Joseph Absi ◽  
Said Zeghloul

In physical human–robot interactions, making the robot perceive in real time the mechanical contact impedance is critical for interactions safety, robot control and haptic rendering for robot teleoperation and can be achieved through online parametric model identification. Probing the viscoelastic properties of tissues is also a medical concern. For soft viscoelastic biological tissues, the Hunt–Crossley model is a contact force model computationally inexpensive while being accurate. As this model is non-linear, a log linear approximation has been proposed to achieve a fast and real-time identification using a recursive least squares approach. In this article, we want to regard the log-linearized expression of the Hunt–Crossley model no more as an approximation, but rather as a valuable empirical mechanical model of soft biological tissues. We show through experimental data fit and sophisticated statistical analysis that the log-linearized Hunt–Crossley model performs always closely to the Hunt–Crossley model and is even often slightly better. The experimental conditions investigated are related to impact and contact interactions, relevant in the context of Cobotics.


Lab on a Chip ◽  
2019 ◽  
Vol 19 (12) ◽  
pp. 2060-2070 ◽  
Author(s):  
Mohamed Elsherif ◽  
Rosalia Moreddu ◽  
Muhammad Umair Hassan ◽  
Ali K. Yetisen ◽  
Haider Butt

The applications of optical fibers are impeded in implantable medical diagnostics due to incompatibility with biological tissues, and immune reaction in vivo.


2017 ◽  
Vol 117 (4) ◽  
pp. 1489-1498 ◽  
Author(s):  
James Day ◽  
Leah R. Bent ◽  
Ingvars Birznieks ◽  
Vaughan G. Macefield ◽  
Andrew G. Cresswell

Muscle spindles provide exquisitely sensitive proprioceptive information regarding joint position and movement. Through passively driven length changes in the muscle-tendon unit (MTU), muscle spindles detect joint rotations because of their in-parallel mechanical linkage to muscle fascicles. In human microneurography studies, muscle fascicles are assumed to follow the MTU and, as such, fascicle length is not measured in such studies. However, under certain mechanical conditions, compliant structures can act to decouple the fascicles, and, therefore, the spindles, from the MTU. Such decoupling may reduce the fidelity by which muscle spindles encode joint position and movement. The aim of the present study was to measure, for the first time, both the changes in firing of single muscle spindle afferents and changes in muscle fascicle length in vivo from the tibialis anterior muscle (TA) during passive rotations about the ankle. Unitary recordings were made from 15 muscle spindle afferents supplying TA via a microelectrode inserted into the common peroneal nerve. Ultrasonography was used to measure the length of an individual fascicle of TA. We saw a strong correlation between fascicle length and firing rate during passive ankle rotations of varying rates (0.1–0.5 Hz) and amplitudes (1–9°). In particular, we saw responses observed at relatively small changes in muscle length that highlight the sensitivity of the TA muscle to small length changes. This study is the first to measure spindle firing and fascicle dynamics in vivo and provides an experimental basis for further understanding the link between fascicle length, MTU length, and spindle firing patterns. NEW & NOTEWORTHY Muscle spindles are exquisitely sensitive to changes in muscle length, but recordings from human muscle spindle afferents are usually correlated with joint angle rather than muscle fascicle length. In this study, we monitored both muscle fascicle length and spindle firing from the human tibialis anterior muscle in vivo. Our findings are the first to measure these signals in vivo and provide an experimental basis for exploring this link further.


Sign in / Sign up

Export Citation Format

Share Document