scholarly journals Determination of Bedaquiline in Human Serum Using Liquid Chromatography-Tandem Mass Spectrometry

2015 ◽  
Vol 59 (9) ◽  
pp. 5675-5680 ◽  
Author(s):  
Jan-Willem C. Alffenaar ◽  
Mathieu Bolhuis ◽  
Kai van Hateren ◽  
Marieke Sturkenboom ◽  
Onno Akkerman ◽  
...  

ABSTRACTBedaquiline, a diarylquinoline for the treatment of multidrug-resistant tuberculosis (TB), relies on exposure-dependent killing. As data on drug exposure in specific populations are scarce, pharmacokinetic studies may be of interest. No simple and robust validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been reported to date. Therefore, a new method using a quadrupole mass spectrometer was developed for analysis of bedaquiline andN-monodesmethyl bedaquiline (M2) in human serum, using deuterated bedaquiline as the internal standard. The calibration curve was linear over a range of 0.05 (lower limit of quantification [LLOQ]) to 6.00 mg/liter for both bedaquiline and M2, with correlation coefficient values of 0.997 and 0.999, respectively. The calculated accuracy ranged from 1.9% to 13.6% for bedaquiline and 2.9% to 8.5% for M2. Within-run precision ranged from 3.0% to 7.2% for bedaquiline and 3.1% to 5.2% for M2, and between-run precision ranged from 0.0% to 4.3% for bedaquiline and 0.0% to 4.6% for M2. Evaluation of serum concentrations in a patient receiving bedaquiline showed high levels at the end of treatment, reflecting accumulation of the drug. More observational pharmacokinetic data are needed to relate altered drug concentrations to clinical outcome or adverse drug effects. A simple LC-MS/MS method to quantify bedaquiline and M2 levels in human serum using a deuterated internal standard has been validated. This method can be used in clinical studies and daily practice.

Author(s):  
C A Chadwick ◽  
L J Owen ◽  
B G Keevil

Background: Dehydroepiandrosterone sulphate (DHEAS) is a steroid that is increasingly being recognized as a potential drug of abuse in many countries. This is due to its reputation as a hormone that may be able to retard the ageing process. The measurement of DHEAS is useful in the diagnosis of medical conditions such as congenital adrenal hyperplasia and polycystic ovary syndrome. Thus, a liquid chromatography-tandem mass spectrometry method has been developed to determine DHEAS concentrations in human serum. Method: The chromatography was performed using a WatersTM 2795 Alliance HT LC system coupled to a Mercury Fusion-RP column fitted with a SecurityGuardTM column. Results: DHEAS and the internal standard, deuterated DHEAS, both had a retention time of 1.5 min. The transition determined by the Micromass QuattroTM tandem mass spectrometer for DHEAS was m/z 367.3>96.7 and for the internal standard m/z 369.3>96.6. The method was linear up to 20 µmol/L; the lower limit of detection and the lower limit of quantitation were both 1 µmol/L. The intra- and interassay imprecision were <11% over a concentration range of 1-18 µmol/L for the in-house quality control and <12% for the intra- and interassay imprecision for the Bio-Rad Lyphocheck QC. Conclusion: The measurement of DHEAS by liquid chromatography-tandem mass spectrometry is robust and has a simple sample preparation procedure with a rapid cycle time of only 4 min.


Sign in / Sign up

Export Citation Format

Share Document