scholarly journals Disposition kinetics of cefamandole during continuous ambulatory peritoneal dialysis.

1986 ◽  
Vol 29 (4) ◽  
pp. 649-653 ◽  
Author(s):  
M Bliss ◽  
M Mayersohn ◽  
T Arnold ◽  
J Logan ◽  
U F Michael ◽  
...  
1993 ◽  
Vol 13 (2) ◽  
pp. 122-125 ◽  
Author(s):  
Rafael Selgas ◽  
Maria-E. Martinez ◽  
Blanca Miranda ◽  
Maria-Auxiliadara Baja ◽  
Jase-Raman Ramera ◽  
...  

Objectives To evaluate the kinetics of calcitriol (1,25(OH)2D3) administered subcutaneously. Study Design Calcitriol kinetics and efficacy after subcutaneous administration were studied in 13 CAPD patients with varying degrees of increased plasma levels of parathyroid hormone (i-PTH). A single dose of 2 μg of calcitriol was administered subcutaneously, and its serum levels at baseline and after 1,2,6,12, and 24 hours were determined. Plasma ionized calcium and i-PTH were also determined at these periods. Results Serum calcitriol levels reached peak levels of 60 and 70 pg/mL at 1 and 2 hours after administration, respectively. These levels decreased thereafter, but remained above baseline values during 24 hours. The mean value of the area under the curve (AUC) was 809±226 pg/mL/hour. Plasma i-PTH levels showed a slight decrease after 1 and 2 hours, returning to baselime levels after this period. Plasma ionized calcium did not show significant changes during the study. A slight pain at the site of injection was mentioned by some patients. Conclusions The subcutaneous route for calcitriol administration achieves theoretically adequate plasma levels in continuous ambulatory peritoneal dialysis (CAPD) patients. This is important when paremteral administration of calcitriol is considered in the treatment of secondary hyperparathyroidism.


Nephron ◽  
1990 ◽  
Vol 54 (1) ◽  
pp. 105-106 ◽  
Author(s):  
Y. Berland ◽  
M. Bues-Charbit ◽  
M. Merzouk ◽  
C. Boutin ◽  
J.P. Cano ◽  
...  

Author(s):  
William J. Lamoreaux ◽  
David L. Smalley ◽  
Larry M. Baddour ◽  
Alfred P. Kraus

Infections associated with the use of intravascular devices have been documented and have been reported to be related to duration of catheter usage. Recently, Eaton et al. reported that Staphylococcus epidermidis may attach to silastic catheters used in continuous ambulatory peritoneal dialysis (CAPD) treatment. The following study presents findings using scanning electron microscopy (SEM) of S. epidermidis adherence to silastic catheters in an in vitro model. In addition, sections of polyvinyl chloride (PVC) dialysis bags were also evaluated by SEM.The S. epidermidis strain RP62A which had been obtained in a previous outbreak of coagulase-negative staphylococcal sepsis at local hospitals was used in these experiments. The strain produced surface slime on exposure to glucose, whereas a nonadherent variant RP62A-NA, which was also used in these studies, failed to produce slime. Strains were grown overnight on blood agar plates at 37°C, harvested from the surface and resuspended in sterile saline (0.85%), centrifuged (3,000 rpm for 10 minutes) and then washed twice in 0.1 M phosphate-buffered saline at pH 7.0. Organisms were resuspended at a concentration of ca. 106 CFU/ml in: a) sterile unused dianeal at 4.25% dextrose, b) sterile unused dianeal at 1.5% dextrose, c) sterile used dialysate previously containing 4.25% dextrose taken from a CAPD patient, and d) sterile used dialysate previously containing 1.5% dextrose taken from a CAPD patient.


Mycoses ◽  
2002 ◽  
Vol 45 (3-4) ◽  
pp. 120-122 ◽  
Author(s):  
S. Cinar ◽  
A. Nedret Koc ◽  
H. Taskapan ◽  
A. Dogukan ◽  
B. Tokgoz ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document