scholarly journals Development of a high-performance liquid chromatographic assay for G418 sulfate (Geneticin).

1997 ◽  
Vol 41 (3) ◽  
pp. 661-664 ◽  
Author(s):  
C Bethune ◽  
T Bui ◽  
M L Liu ◽  
M A Kay ◽  
R J Ho

We have developed a chromatographic assay with high sensitivity and specificity to quantify G418 sulfate (Geneticin), an antibiotic used routinely in molecular genetics experiments for selecting eukaryotic transformants. With this method, G418 in tissues and plasma samples can be quantitated without the confounding factors often associated with biological assays. After removal of proteins in homogenized tissue or plasma samples with methanol (2:1, vol/vol), the amino group of G418 was derivatized with 1-fluoro-2,4-dinitrobenzene (DNFB) to form the UV-visible G418-DNFB product. The DNFB-derivatized G418 was separated on a reversed-phase C18 column with an acetonitrile and water gradient as the mobile phase. Under these assay conditions, the detection limit for G418 sulfate in buffer, plasma, and tissues was recorded at 78 ng/ml and the linearity was recorded for concentrations up to 100 micrograms/ml. The data obtained from this analysis indicate that this assay can be used for the quantitative determination of G418 sulfate in plasma and tissue samples.

2007 ◽  
Vol 4 (1) ◽  
pp. 109-116 ◽  
Author(s):  
K. Basavaiah ◽  
B. C. Somashekar

A rapid, highly sensitive high performance liquid chromatographic method has been developed for the determination of finasteride(FNS) in bulk drug and in tablets. FNS was eluted from a ODS C18reversed phase column at laboratory temperature (30 ± 2°C) with a mobile phase consisting of methanol and water (80+20) at a flow rate of 1 mL min-1with UV detection at 225 nm. The retention time was ∼ 6.1 min and each analysis took not more than 10 min. Quantitation was achieved by measurement of peak area without using any internal standard. Calibration graph was linear from 2.0 to 30 μg mL-1with limits of detection (LOD) and quantification (LOQ) being 0.2 and 0.6 μg mL-1, respectively. The method was validated according to the current ICH guidelines. Within-day co efficients of variation (CV) ranged from 0.31 to 0.69% and between-day CV were in the range 1.2-3.2%. Recovery of FNS from the pharmaceutical dosage forms ranged from 97.89 – 102.9 with CV of 1.41-4.13%. The developed method was compared with the official method for FNS determination in its tablet forms.


2013 ◽  
Vol 2013 ◽  
pp. 1-4
Author(s):  
Suying Ma ◽  
Haixia Lv ◽  
Xiaojun Shang

A high performance liquid chromatographic (HPLC) method with UV detector for the determination of dyclonine hydrochloride and a gas chromatography (GC) method with flame ionization detector (FID) for the determination of camphor and menthol in lotion were developed. The developed HPLC method involved using a SinoChoom ODS-BP C18reversed-phase column (5 μm, 4.6 mm × 200 mm) and mobile phase consisting of acetonitrile : water : triethylamine in a ratio of 45 : 55 : 1.0; pH was adjusted to 3.5 with glacial acetic acid. The developed GC method for determination of camphor and menthol involved using an Agilent 19091J-413 capillary chromatographic column (30 m × 320 μm × 0.25 μm). The two methods were validated according to official compendia guidelines. The calibration of dyclonine hydrochloride for HPLC method was linear over the range of 20–200 μg/mL. The retention time was found at 6.0 min for dyclonine hydrochloride. The calibration of camphor and menthol of GC method was linear over the range of 10–2000 μg/mL. The retention time was found at 2.9 min for camphor and 3.05 min for menthol. The proposed HPLC and GC methods were proved to be suitable for the determination of dyclonine hydrochloride, camphor, and menthol in lotion.


2016 ◽  
Vol 13 (2) ◽  
pp. 447-457 ◽  
Author(s):  
Baghdad Science Journal

High-performance liquid chromatographic methods are used for the determination of water-soluble vitamins with UV-Vis. Detector. A reversed-phase high-performance liquid chromatographic has been developed for determination of water-soluble vitamins. Identification of compounds was achieved by comparing their retention times and UV spectra with those of standards solution. Separation was performed on a C18 column, using an isocratic 30% (v/v) acetonitril in dionozed water as mobile phase at pH 3.5 and flow rate 1.0m/min. The method provides low detection and quantification limits, good linearity in a large concentration interval and good precision. The detection limits ranged from 0.01 to 0.025µg/ml. The accuracy of the method was tested by measuring average recovery values ranged between 94% - 101 %. For standerd solution, and 93%-99% of honey bee samples.


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (07) ◽  
pp. 43-49
Author(s):  
B.P. Manjula ◽  
V. G Joshi ◽  
Siddamsetty Ramachandra Setty ◽  
M Geetha ◽  

Tea tree oil, an active ingredient of skin, hair and nail care cosmeceuticals, has claims for topical antimicrobial, analgesic and anti-inflammatory activity. Its complex composition is governed by ISO 4730:2017. Terpinene-4-ol is the principal constituent of the oil (35% - 48%) followed by γ-terpinene (14% -28%), α-terpinene (6%-12%) and 1,8-cineole (≤15%). A reversed-phase, isocratic high performance liquid chromatographic method has been developed and validated for routine determination of tea tree oil based on1,8-cineole content in bulk and commercially available cosmeceuticals using C18 column, methanol-water (70:30 v/v) as mobile phase and flow rate of 1mL/min. UV detection was done at 200 nm. Linearity of the method was established for 20-100μL/mL (R2 = 0.9992) with LOD, LOQ values of 0.5594 μL/mL and 5.5941μL/mL respectively. The % RSD values for robustness and precision were <1% and recovery ranged between 99.09-102.96%. The method was successfully applied for determination of 1,8-cineole content in cosmeceuticals.


1988 ◽  
Vol 34 (1) ◽  
pp. 87-90 ◽  
Author(s):  
K Abe ◽  
R Konaka

Abstract We describe a "high-performance" liquid-chromatographic method for determining 3-methoxy-4-hydroxyphenylethylene glycol (MHPG) in human urine. MHPG is separated on a reversed-phase column with isocratic elution, oxidized with sodium metaperiodate, and its absorbance measured at 365 nm. This method shows higher specificity, less interference for MHPG than methods involving electrochemical or fluorescence detection. Post-column derivatization of MHPG with periodate yields vanillin. The detection limit (twice the signal-to-noise ratio) in urine samples was 0.08 mg/L. Mean analytical recovery was 72%. Within-assay and day-to-day CVs were 2.9% and 6.5%, respectively. Reference intervals for MHPG in 24-h urine from apparently healthy subjects were 0.85-3.24 mg/day for men and 0.63-2.20 mg/day for women. In terms of creatinine excretion, the respective reference intervals were 0.55-1.99 and 0.70-1.96 mg per gram of creatinine.


Sign in / Sign up

Export Citation Format

Share Document