scholarly journals THE BLOOD-AGAR PLATE FOR SPORE-FORMING ANAËROBES

1926 ◽  
Vol 11 (5) ◽  
pp. 305-321
Author(s):  
Luther Thompson
Author(s):  
Kankan Gao ◽  
Qiulian Deng ◽  
Lianfen Huang ◽  
Chien-Yi Chang ◽  
Huamin Zhong ◽  
...  

Maternal vaginal/rectal colonization of group B streptococcus (GBS) is a main risk for neonatal invasive infection. Efficient determination of GBS colonization in pregnant women is crucial. This study aimed to investigate the prevalence of GBS carriage and evaluate the diagnostic performance of six methodologies for GBS screening conducted in China, including blood agar plate, liquid chromogenic medium, and loop-mediated isothermal amplification (LAMP) without pre-enrichment, chromogenic agar plate with pre-enrichment, and GBS antigen detection without and with pre-enrichment in comparison with the standard reference method (Lim broth-enriched subculture with plating on 5% sheep blood agar). Vaginal/rectal swabs were collected from 1,281 pregnant women at 35–37 weeks of gestation. Of them, 309 were taken in triplicate, one for Lim broth-enriched subculture, one for blood agar plate, and the third for GBS antigen detection (Reagent W); 177 were acquired in duplicate, one for Lim broth-enriched subculture and the other for GBS antigen detection (Reagent H); 502 were obtained in duplicate, one for Lim broth-enriched subculture and the other for liquid chromogenic medium; 158 were collected in duplicate, one for Lim broth-enriched subculture and the other for LAMP; and 135 were inoculated in Lim broth-enriched for GBS antigen detection (Reagent W) and subculture with chromogenic agar plate and 5% blood agar plate. The overall prevalence of GBS carriage was 10.1% (130/1,281, 95% CI: 8.5–12.1%) according to the standard reference method. Compared with the standard reference method, the LAMP had excellent performance of sensitivity (100%, 95%CI: 83.4–100%), specificity (94%, 95%CI: 88.1–97.1%), and Yoden index (0.940); as well as the blood agar plate with sensitivity (81.5%, 95%CI: 61.3–93.0%), specificity (100%, 95%CI: 98.3–100.0%), and Yoden index (0.815). The other four methods were not sufficient to reach the threshold in terms of sensitivity or specificity compared to the standard reference method. Furthermore, for LAMP, results can be obtained within 0.5–1 h, while for blood agar plate, which needed 24–48 h, and further identification was required. Our data suggested that the performance of LAMP was highly comparable to the standard Lim broth-enriched subculture and LAMP is considered as an alternative for fast and accurate GBS screening.


2020 ◽  
Vol 2020 ◽  
pp. 1-6 ◽  
Author(s):  
Sangeeta Umesh Nayak ◽  
Anushka Kumari ◽  
Valliammai Rajendran ◽  
Vijendra Pal Singh ◽  
Ashwini Hegde ◽  
...  

Objective. The risk to dentists, assistants, and patients of infectious diseases through aerosols has long been recognized. The aim of this study was to evaluate and compare the efficacy of commercially available preprocedural mouth rinses containing 0.2% chlorhexidine (CHX) gluconate, Befresh™ herbal mouthwash, and water in reducing the levels of viable bacteria in aerosols. Materials & Methods. This was a single-center, double-masked, placebo-controlled, randomized, three-group parallel design study. 30 patients (10 patients in each group) were recruited in the study. Patient rinsed mouth with 10 ml of CHX, 10 ml Befresh™, or 10 ml water. All the patients underwent supragingival ultrasonic scaling for a minimum of 30 min. The aerosol collection was done using a blood agar plate. The blood agar plates were kept approximately 12 inches from the patient’s mouth. The microbial culture was analyzed. The colony-forming unit (CFU) counting in all three groups was assessed using one-way ANOVA test to compare among the groups (p value <0.001). The intergroup comparison was done using the post hoc Tukey test. Result. There was a marked reduction in the CFU in the CHX group in all three areas. This was followed by Befresh™ (Sagar Pharmaceuticals) mouthwash. There was no reduction in the CFU of the water group. Conclusion. This study proves that a regular preprocedural mouth rinse could significantly reduce the majority bacteria present in aerosols generated by the use of an ultrasonic unit, and Befresh™ mouth rinse was found to be equally effective in reducing the aerosol contamination to 0.2% CHX gluconate.


2018 ◽  
Vol 23 (4) ◽  
pp. 311-314 ◽  
Author(s):  
Vi Ean Tan ◽  
Alan T. Evangelista ◽  
Dominick M. Carella ◽  
Daniel Marino ◽  
Wayne S. Moore ◽  
...  

OBJECTIVES There is a lack of standardization and supporting data regarding the duration preassembled and preprimed extracorporeal membrane oxygenation (ECMO) circuits are expected to be sterile. Therefore, the purpose of this study was to prospectively evaluate whether preassembled and preprimed ECMO circuits could maintain sterility for a period up to 65 days. DESIGN Four ECMO circuits (2 neonatal/pediatric¼” and 2 adolescent/adult ⅜ ”) were assembled and primed under sterile conditions and maintained at room temperature. Culture samples were obtained from each circuit and plated within 1 hour. Culture samples were obtained on day 0 when assembled and primed then every 5 days up to day 65. Samples were plated on several different media including the following: blood agar plate: trypticase soy agar with 5% sheep blood, MacConkey agar, and thioglycollate broth then incubated at 35°C for 3 days. RESULTS All cultures obtained from the priming solution from of the¼” and ⅜ ” ECMO circuits produced no microbial or fungal growth for the 65-day study period. CONCLUSION These pilot data suggest preprimed ECMO circuits may maintain sterility for a period up to 65 days. Additional studies evaluating a larger number of ECMO circuits are needed to confirm these findings.


1979 ◽  
Vol 9 (1) ◽  
pp. 144-146 ◽  
Author(s):  
T Kurzynski ◽  
C Meise ◽  
R Daggs ◽  
A Helstad

The primary plate bacitracin differentiation disk susceptibility test identified 85% of group A streptococci from throat cultures on SXT-BA(CO2) plates within 24 h, as compared to only 26% on a conventional sheep blood agar plate.


2021 ◽  
Vol 2 (1) ◽  
pp. 34-38
Author(s):  
Silvia Sulistiani ◽  
Nur Eka Fitriana ◽  
Widi Nurwanti
Keyword(s):  
Dry Heat ◽  

Sterilisasi alat kedokteran gigi merupakan hal yang sangat penting untuk menghindari infeksi silang. Penelitian ini bertujuan untuk melihat efektifitas sterilisasi alat kedokteran gigi dengan dry heat sterilitator dan teknik boiling. Metode: sampel penelitian ini adalah kaca mulut yang telah digunakan untuk praktikum klinik. Pengambilan sampel menggunakan teknik accidental sampling dengan jumlah sampel 20 buah. Kaca mulut sebelum dan sesudah disterilkan, ditempelkan pada Blood Agar Plate (BAP) kemudian diinkubasi selama 1 x 24 jam. Hasil: Uji Wilcoxon menunjukkan penurunan jumlah bakteri yang siginifikan pada dry heat sterilisator (P<0,005) sedangkan pada teknik boiling tidak signifikan (P>0,005). Kesimpulan: Dry heat sterilisator lebih efektif dalam mengurangi bakteri pada instrumen dibandingkan teknik boiling.


Sign in / Sign up

Export Citation Format

Share Document