Method for extending the bandwidth of variable gain amplifiers

2014 ◽  
Vol 43 (7) ◽  
pp. 459-461
Author(s):  
E. O. Belousov ◽  
A. G. Timoshenko
IEEE Access ◽  
2020 ◽  
Vol 8 ◽  
pp. 197276-197286
Author(s):  
Jiri Petrzela ◽  
Roman Sotner

2009 ◽  
Vol 18 (07) ◽  
pp. 1287-1308 ◽  
Author(s):  
EMAN A. SOLIMAN ◽  
SOLIMAN A. MAHMOUD

This paper presents different novel CMOS realizations for the differential difference operational floating amplifier (DDOFA). The DDOFA was first introduced in Ref. 1 and was used to realize different analog circuits like integrators, filters and variable gain amplifiers. New CMOS realizations for the DDOFA are introduced in this literature. Furthermore the DDOFA is modified to realize a fully differential current conveyor (FDCC). Novel CMOS realizations of the FDCC are presented. The FDCC is used to realize second-order band pass–low-pass filter. Performance comparisons between the different realizations of the DDOFA and FDCC are given in this literature. PSPICE simulations of the overall proposed circuits are given using 0.25 μm CMOS Technology from TMSC MOSIS model and dual supply voltages of ±1.5 V.


Author(s):  
K.H. Snow ◽  
J.J. Komiak ◽  
D.A. Bates

2008 ◽  
Vol E91-C (5) ◽  
pp. 788-797
Author(s):  
Q.-H. DUONG ◽  
C.-W. KIM ◽  
S.-G. LEE

2008 ◽  
Vol E91-C (6) ◽  
pp. 854-861 ◽  
Author(s):  
K. IIZUKA ◽  
M. KOUTANI ◽  
T. MITSUNAKA ◽  
H. KAWAMURA ◽  
S. TOYOYAMA ◽  
...  

2021 ◽  
Vol 6 (2) ◽  
pp. 39-46
Author(s):  
Bao My Nguyen Thi ◽  
Van Sy Nguyen ◽  
Van Tien Vu ◽  
Quang Tuan Ho ◽  
Thuy Mai Nguyen Thi ◽  
...  

X-ray measurement equipment is designed which utilizes a pair of photodiode detectors. The equipment is designed which utilizes a pair of photodiode detectors units which receive X-rays through filters with different attenuation coefficients for X-rays. The photodiode detector units preferably includes two pairs of photodiode detectors arranged symmetrically in four quadrants with the diodes in each detector unit in diagonally opposite quadrants. The outputs of the detector units are passed to variable gain amplifiers, gains of which are adjusted to bring the output voltages within a desired range, and the outputs of the amplifiers are integrated by integrators. After a selected period of time, the integration is stopped and the output voltages of the integrators are held and transmitted to an analog-to-digital converter. The ratio of the two output signals from a pair of photodiode detectors represents the kVp value of the X-ray machine and another pair of photodiode detectors used to measure the relative current in milliamps (mA) and exposure time of the x-ray unit.In this study,  the equipment have been made for measuring the characteristics of X-Ray with an accuracy of kVp (kV), I (mA) is 5% and the 2% T.


2013 ◽  
Vol 55 (11) ◽  
pp. 2666-2670
Author(s):  
Bayaner Arigong ◽  
Hualiang Zhang ◽  
Sungyong Jung ◽  
Hyoungsoo Kim

Sign in / Sign up

Export Citation Format

Share Document