scholarly journals Nephrosonography in Infants and Children: A New Technique

BMJ ◽  
1972 ◽  
Vol 2 (5815) ◽  
pp. 689-691 ◽  
Author(s):  
E. A. Lyons ◽  
J. E. E. Fleming ◽  
G. C. Arneil ◽  
A. V. Murphy ◽  
E. M. Sweet ◽  
...  
PEDIATRICS ◽  
1956 ◽  
Vol 18 (3) ◽  
pp. 466-466

A new technique for the insertion of a polyethylene catheter into a vein for continuous intravenous infusion is described. Noteworthy amongst the advantages is that the patency of the vein is not destroyed. The technique does not involve ligation or division of the vein. Simple apparatus to facilitate the use of the technique is available from a commercial firm. Detailed description aided by diagrammatic illustration is provided.


1978 ◽  
Vol 13 (3) ◽  
pp. 213-215 ◽  
Author(s):  
William R. Cranley ◽  
John F. O'Connor ◽  
Neil R. Feins

1997 ◽  
Vol 106 (3) ◽  
pp. 199-209 ◽  
Author(s):  
Ellen M. Friedman

The determination of the cause of stridor in the infant and child is an important directive for the otolaryngologist. The limitations of current clinical diagnostic techniques have provided the impetus for pursuing newer, more practical techniques to diagnose vocal cord paralysis in children. The purpose of this paper is to describe a new technique to image the larynx and determine its role in discerning vocal cord paralysis in children. This study began with an animal study (lamb model) demonstrating that computerized ultrasound can accurately delineate laryngeal anatomy and function. The human protocol included 27 patients (age 1 day to 14 years): 15 with normal larynges and 12 with vocal cord paralysis. Recorded ultrasound studies of these subjects were compiled in a randomly ordered videotape and presented twice and viewed in a blinded manner by four expert raters. Statistical analysis of their readings revealed that ultrasound is a highly accurate technique to document vocal cord paralysis, with a high degree of interrater and intrarater reliability. Beyond the accuracy and consistency of computerized ultrasound, there are many other aspects of this technique that make it clinically attractive. Laryngeal ultrasound is noninvasive, painless, and widely accepted. It is relatively safe, with no radiation exposure and no need for sedation or anesthesia. It is well tolerated by patients and their families. The results are easily displayed and recorded and available for hard copy storage. This investigation should not be interpreted as an endorsement for laryngeal ultrasound as a replacement for endoscopy in children. This work does indicate, however, that ultrasound is a technique that can accurately address the special issue of vocal cord mobility in infants and children. At present, this is the primary use for laryngeal ultrasound, although with additional investigation and sophistication it is likely that ultrasound of the larynx may become useful for other purposes.


2015 ◽  
Vol 25 (1) ◽  
pp. 15-23 ◽  
Author(s):  
Ryan W. McCreery ◽  
Elizabeth A. Walker ◽  
Meredith Spratford

The effectiveness of amplification for infants and children can be mediated by how much the child uses the device. Existing research suggests that establishing hearing aid use can be challenging. A wide range of factors can influence hearing aid use in children, including the child's age, degree of hearing loss, and socioeconomic status. Audiological interventions, including using validated prescriptive approaches and verification, performing on-going training and orientation, and communicating with caregivers about hearing aid use can also increase hearing aid use by infants and children. Case examples are used to highlight the factors that influence hearing aid use. Potential management strategies and future research needs are also discussed.


Sign in / Sign up

Export Citation Format

Share Document