Surgery for subacromial impingement syndrome in relation to intensities of occupational mechanical exposures across 10-year exposure time windows

2017 ◽  
Vol 75 (3) ◽  
pp. 176-182 ◽  
Author(s):  
Annett Dalbøge ◽  
Poul Frost ◽  
Johan Hviid Andersen ◽  
Susanne Wulff Svendsen

ObjectivesWe aimed to identify intensities of occupational mechanical exposures (force, arm elevation and repetition) that do not entail an increased risk of surgery for subacromial impingement syndrome (SIS) even after prolonged durations of exposure. Additionally, we wanted to evaluate if exposure to hand-arm vibration (HAV) is an independent risk factor.MethodsWe used data from a register-based cohort study of the entire Danish working population (n=2 374 403). During follow-up (2003–2008), 14 118 first-time events of surgery for SIS occurred. For each person, we linked register-based occupational codes (1993–2007) to a general population job exposure matrix to obtain year-by-year exposure intensities on measurement scales for force, upper arm elevation >90° and repetition and expert rated intensities of exposure to HAV. For 10-year exposure time windows, we calculated the duration of exposure at specific intensities above minimal (low, medium and high). We used a logistic regression technique equivalent to discrete survival analysis adjusting for cumulative effects of other mechanical exposures.ResultsWe found indications of safe exposure intensities for repetition (median angular velocity <45°/s), while force exertion ≥10% of maximal voluntary electrical activity and upper arm elevation >90° >2 min/day implied an increased risk reaching ORs of 1.7 and 1.5 after 10 years at low intensities. No associations were found for HAV.ConclusionsWe found indications of safe exposure intensities for repetition. Any intensities of force and upper arm elevation >90° above minimal implied an increased risk across 10-year exposure time windows. No independent associations were found for HAV.

Author(s):  
Da-In An ◽  
Jung-Eun Park ◽  
Chang-Hyung Lee ◽  
Soo-Yong Kim

BACKGROUD: Reliable scapular upward rotation and anterior-posterior tilt data are required for patients with subacromial impingement syndrome (SIS). Only a few studies have explored the reliability of such measurements derived using a modified inclinometer. OBJECTIVES: To determine the relative and absolute reliability of scapular upward rotation and anterior-posterior tilt measurements derived using a modified digital inclinometer in patients with SIS. METHOD: Seventeen SIS patients were assessed twice within 1 week. We determined the relative and absolute measurement reliability by calculating the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and minimal clinically important difference (MCID). Both intra- and interrater reliability were determined. RESULTS: The intra-rater reliability (both measurements) was high (0.72–0.88), and the interrater ICC was high to excellent (0.72–0.98). Clinically acceptable SEM and MCID values were obtained for scapular upward rotation (SEM: 4.28–9.33∘, MCID: 5.1–11.3∘) and anterior-posterior tilt (SEM: 3.72–7.55∘, MCID: 2.5–10.8∘). CONCLUSIONS: Measurements of scapular upward rotation and anterior-posterior tilt using a modified digital inclinometer reliably reveal scapular position and kinematics in patients with SIS.


Sign in / Sign up

Export Citation Format

Share Document