Fréchet Derivative with Respect to the Shape of an Internal Electrode in Electrical Impedance Tomography

2010 ◽  
Vol 70 (6) ◽  
pp. 1878-1898 ◽  
Author(s):  
Nuutti Hyvönen ◽  
Kimmo Karhunen ◽  
Aku Seppänen
2012 ◽  
Vol 2012 ◽  
pp. 1-10 ◽  
Author(s):  
J. Nasehi Tehrani ◽  
C. Jin ◽  
A. L. McEwan

There is a need in critical care units for continuous cardiopulmonary monitoring techniques. ECG gated electrical impedance tomography is able to localize the impedance variations occurring during the cardiac cycle. This method is a safe, inexpensive and potentially fast technique for cardiac output imaging but the spatial resolution is presently low, particularly for central locations such as the heart. Many parameters including noise deteriorate the reconstruction result. One of the main obstacles in cardiac imaging at the heart location is the high impedance of lungs and muscles on the dorsal and posterior side of body. In this study we are investigating improvements of the measurement and initial conductivity estimation of the internal electrode by modelling an internal electrode inside the esophagus. We consider 16 electrodes connected around a cylindrical mesh. With the random noise level set near 0.05% of the signal we evaluated the Graz consensus reconstruction algorithm for electrical impedance tomography. The modelling and simulation results showed that the quality of the target in reconstructed images was improved by up to 5 times for amplitude response, position error, resolution, shape deformation and ringing effects with perturbations located in cardiac related positions when using an internal electrode.


2013 ◽  
Vol 2013 ◽  
pp. 1-9 ◽  
Author(s):  
Hyeuknam Kwon ◽  
Alistair L. McEwan ◽  
Tong In Oh ◽  
Adnan Farooq ◽  
Eung Je Woo ◽  
...  

Electrical Impedance Tomography (EIT) is a very attractive functional imaging method despite the low sensitivity and resolution. The use of internal electrodes with the conventional reconstruction algorithms was not enough to enhance image resolution and accuracy in the region of interest (ROI). We propose a local ROI imaging method with internal electrodes developed from careful analysis of the sensitivity matrix that is designed to reduce the sensitivity of the voxels outside the local region and optimize the sensitivity of the voxel inside the local region. We perform numerical simulations and physical measurements to demonstrate the localized EIT imaging method. In preliminary results with multiple objects we show the benefits of using an internal electrode and the improved resolution due to the local ROI image reconstruction method. The sensitivity is further increased by allowing the surface electrodes to be unevenly spaced with a higher density of surface electrodes near the ROI. Also, we analyse how much the image quality is improved using several performance parameters for comparison. While these have not yet been studied in depth, it convincingly shows an improvement in local sensitivity in images obtained with an internal electrode in comparison to a standard reconstruction method.


Author(s):  
Bruno Furtado de Moura ◽  
francisco sepulveda ◽  
Jorge Luis Jorge Acevedo ◽  
Wellington Betencurte da Silva ◽  
Rogerio Ramos ◽  
...  

1992 ◽  
Vol 28 (11) ◽  
pp. 974-976 ◽  
Author(s):  
R. Gadd ◽  
F. Vinther ◽  
P.M. Record ◽  
P. Rolfe