LIMITS ON PRODUCTION OF NARROW BAND PHOTONS FROM INVERSE COMPTON SCATTERING

2007 ◽  
Vol 22 (23) ◽  
pp. 4333-4342 ◽  
Author(s):  
J. ROSENZWEIG ◽  
O. WILLIAMS

In using the inverse Compton scattering (ICS) interaction as a high brilliance, short wavelength radiation source, one collides two beams, one an intense laser, and the other a high charge, short pulse electron beam. In order to maximize the flux of photons from ICS, one must focus both beams strongly, which implies both use of short beams and the existence of large angles in the interaction. One aspect of brilliance is the narrowness of the wavelength band emitted by the source. This paper explores the limits of ICS-based source brilliance based on inherent wavelength broadening effects that arise due to focal angles, laser energy density, and finite laser pulse length effects. It is shown that for a nominal 1% desired bandwidth, that one obtains approximately one scattered photon per electron in a head-on collision geometry.

2014 ◽  
Vol 21 (6) ◽  
pp. 1327-1332 ◽  
Author(s):  
Toshiharu Fujii ◽  
Naoto Fukuyama ◽  
Chiharu Tanaka ◽  
Yoshimori Ikeya ◽  
Yoshiro Shinozaki ◽  
...  

The fundamental performance of microangiography has been evaluated using the S-band linac-based inverse-Compton scattering X-ray (iCSX) method to determine how many photons would be required to apply iCSX to human microangiography. ICSX is characterized by its quasi-monochromatic nature and small focus size which are fundamental requirements for microangiography. However, the current iCSX source does not have sufficient flux for microangiography in clinical settings. It was determined whether S-band compact linac-based iCSX can visualize small vessels of excised animal organs, and the amount of X-ray photons required for real time microangiography in clinical settings was estimated. The iCSX coupled with a high-gain avalanche rushing amorphous photoconductor camera could visualize a resolution chart with only a single iCSX pulse of ∼3 ps duration; the resolution was estimated to be ∼500 µm. The iCSX coupled with an X-ray cooled charge-coupled device image sensor camera visualized seventh-order vascular branches (80 µm in diameter) of a rabbit ear by accumulating the images for 5 and 30 min, corresponding to irradiation of 3000 and 18000 iCSX pulses, respectively. The S-band linac-based iCSX visualized microvessels by accumulating the images. An iCSX source with a photon number of 3.6 × 103–5.4 × 104times greater than that used in this study may enable visualizing microvessels of human fingertips even in clinical settings.


2017 ◽  
Vol 7 (1) ◽  
Author(s):  
Siddharth Malu ◽  
Abhirup Datta ◽  
Sergio Colafrancesco ◽  
Paolo Marchegiani ◽  
Ravi Subrahmanyan ◽  
...  

2015 ◽  
Vol 48 (2) ◽  
pp. 558-564 ◽  
Author(s):  
Giacomo Resta ◽  
Boris Khaykovich ◽  
David Moncton

A comprehensive description and ray-tracing simulations are presented for symmetric nested Kirkpatrick–Baez (KB) mirrors, commonly used at synchrotrons and in commercial X-ray sources. This paper introduces an analytical procedure for determining the proper orientation between the two surfaces composing the nested KB optics. This procedure has been used to design and simulate collimating optics for a hard-X-ray inverse Compton scattering source. The resulting optical device is composed of two 12 cm-long parabolic surfaces coated with a laterally graded multilayer and is capable of collimating a 12 keV beam with a divergence of 5 mrad (FWHM) by a factor of ∼250. A description of the ray-tracing software that was developed to simulate the graded multilayer mirrors is included.