Just-In-Time Test Smell Detection and Refactoring

Author(s):  
Stefano Lambiase ◽  
Andrea Cupito ◽  
Fabiano Pecorelli ◽  
Andrea De Lucia ◽  
Fabio Palomba
Keyword(s):  
1954 ◽  
Vol 26 (5) ◽  
pp. 781-788 ◽  
Author(s):  
Sheldon S. Waldstein ◽  
Bruce T. Forsyth ◽  
Edward J. Jahnke

Author(s):  
F. Jacob Seagull ◽  
Danny Ho ◽  
James Radcliffe ◽  
Yan Xiao ◽  
Peter Hu ◽  
...  

2010 ◽  
Vol 30 (04) ◽  
pp. 212-216 ◽  
Author(s):  
R. Jovic ◽  
M. Hollenstein ◽  
P. Degiacomi ◽  
M. Gautschi ◽  
A. Ferrández ◽  
...  

SummaryThe activated partial thromboplastin time test (aPTT) represents one of the most commonly used diagnostic tools in order to monitor patients undergoing heparin therapy. Expression of aPTT coagulation time in seconds represents common practice in order to evaluate the integrity of the coagulation cascade. The prolongation of the aPTT thus can indicate whether or not the heparin level is likely to be within therapeutic range. Unfortunately aPTT results are highly variable depending on patient properties, manufacturer, different reagents and instruments among others but most importantly aPTT’s dose response curve to heparin often lacks linearity. Furthermore, aPTT assays are insensitive to drugs such as, for example, low molecular weight heparin (LMWH) and direct factor Xa (FXa) inhibitors among others. On the other hand, the protrombinase-induced clotting time assay (PiCT®) has been show to be a reliable functional assay sensitive to all heparinoids as well as direct thrombin inhibitors (DTIs). So far, the commercially available PiCT assay (Pefakit®-PiCT®, DSM Nutritional Products Ltd. Branch Pentapharm, Basel, Switzerland) is designed to express results in terms of units with the help of specific calibrators, while aPTT results are most commonly expressed as coagulation time in seconds. In this report, we describe the results of a pilot study indicating that the Pefakit PiCT UC assay is superior to the aPTT for the efficient monitoring of patients undergoing UFH therapy; it is also suitable to determine and quantitate the effect of LMWH therapy. This indicates a distinct benefit when using this new approach over the use of aPPT for heparin monitoring.


1992 ◽  
Vol 67 (01) ◽  
pp. 042-045 ◽  
Author(s):  
Armando Tripodi ◽  
Arnaldo Arbini ◽  
Veena Chantarangkul ◽  
Pier Mannuccio Mannucci

SummaryRelipidated recombinant tissue factor (r-TF) has been assessed in comparison with conventional rabbit brain thromboplastin (Manchester Reagent) for its suitability for measurement of prothrombin time (PT). The International Sensitivity Index (ISI) of r-TF calibrated against the International Reference Preparation BCT/253 (human plain) was found to be 0.96 and 1.12 with instrumental and manual techniques. Our study of plasmas from patients with congenital deficiencies of clotting factors covering a wide range of severity demonstrates that r-TF is able to detect even minor deficiencies of factors involved in the extrinsic and common coagulation pathways. Patients with liver diseases were correctly diagnosed with a prevalence of abnormal results comparable for both reagents. Between-assay reproducibility expressed as coefficient of variation was 2.3 % and 3.9 % at normal and abnormal PT levels.In conclusion, our evaluation shows that relipidated r-TF possesses the necessary requisites of sensitivity, diagnostic accuracy and reproducibility which make it a suitable candidate for PT determination both for monitoring oral anticoagulant therapy and diagnosing congenital and acquired clotting factor deficiencies. Moreover, being a highly defined reagent it may constitute a step forward in the standardization of PT testing.


1969 ◽  
Vol 21 (03) ◽  
pp. 516-523
Author(s):  
H Engelberg ◽  
L. P Engelberg

SummaryThe addition of small amounts of extrinsic thromboplastin or of thrombin to blood in vitro accelerated coagulation more frequently and to a greater extent when determined by the flowing time test than when measured by the silicone clotting time, or by the blood or plasma heparin tolerance tests. Similar results were obtained when intrinsic thromboplastin formation was stimulated by contact with glass. However there was little or no acceleration of the flowing clotting time of plasma obtained from aliquots of the thromboplastin-containing blood. These results indicate that the flowing clotting time (thrombus formation time) of whole blcod is a more reliable test of hypercoagulability than previously described blood or plasma clotting time tests.


Sign in / Sign up

Export Citation Format

Share Document