Design of intelligent ventilation system based on MCU

Author(s):  
Xie yongzhi ◽  
Tan-wei ◽  
Li yin
Keyword(s):  
2007 ◽  
Vol 14 (2) ◽  
pp. 201-223
Author(s):  
Chin-Lung Chang ◽  
Chang-Hsien Tai ◽  
Chien-Hsiung Tsai ◽  
Yu-Ren Wang ◽  
Qing-Shan Hon

2020 ◽  
Vol 38 (9A) ◽  
pp. 1257-1275
Author(s):  
Wisam M. Mareed ◽  
Hasanen M. Hussen

 Elevated CO2 rates in a building affect the health of the occupant. This paper deals with an experimental and numerical analysis conducted in a full-scale test room located in the Department of Mechanical Engineering at the University of Technology. The experiments and CFD were conducted for analyzing ventilation performance. It is a study on the effect of the discharge airflow rate of the ceiling type air-conditioner on ventilation performance in the lecture room with the mixing ventilation. Most obtained findings show that database and questionnaires analyzed prefer heights between 0.2 m to 1.2 m in the middle of an occupied zone and breathing zone height of between 0.75 m to 1.8 given in the literature surveyed. It is noticed the mismatch of internal conditions with thermal comfort, and indoor air quality recommended by [ASHRAE Standard 62, ANSI / ASHRAE Standard 55-2010]. CFD simulations have been carried to provide insights on the indoor air quality and comfort conditions throughout the classroom. Particle concentrations, thermal conditions, and modified ventilation system solutions are reported.


2019 ◽  
Vol 2 (1) ◽  
pp. 23-27
Author(s):  
Ahmad Nikpey ◽  
Hamzeh Saeidabadi ◽  
Salman Sheikhi ◽  
Saeed Yari ◽  
Tayyebeh Jaddi Madarsara

Background: Appliance manufacturing boom is very high hand customers always have a great deal of attention to products that have low energy consumption, therefore the use of isocyanates MDI as a thermal insulation in the body of the refrigerator and is also widely used as a binder in the production of washing machines.  MDI isocyanate study the effects on the respiratory capacity of formers injection was done foam material in a household appliance company Method: this case control study in 1395 and a household appliance manufacturing company in the province of Qazvin 20 personnel working injected foam material is exposed to isocyanates ,for example administrative personnel and 20 served as controls using medical records these values breathing capacity  FVC , FEV1 , FEV1/FVC in  both 1390 and 1394 extracted using SPSS software and paired T-TEST data were analyzed. Results: Measuring the concentration of isocyanate in 90 blocks in the cabin and tap lid above the limit, which was due to the failure of the ventilation system, in 94 years due to the good performance of the ventilation system in the isocyanate concentration was at the limit. According to their experiences foam material is injected every three indexes FVC, FEV1, FEV1/FVC had significant losses, FEV1 and FVC decline among which were a significant level. (p=0.036, p= 0.008) the control samples also non- significant decline in the indicators that this can be attributed to aging. Conclusion: It is known that exposure to isocyanate materials decreased respiratory capacity is personnel, to postpone it to the desired function ventilation system. it would be desirable to postpone the operation of the ventilation system and non-isocyanate leak on the ground, work, be a lot of attention. even with the improvement of the job must be conservative’s injection foam material is exposed to isocyanates be included in the list of hard and hazardous jobs.   Keywords: MDI, respiratory exposure, respiratory capacity, workers inject foam material.


Author(s):  
Tshokey Tshokey ◽  
Pranitha Somaratne ◽  
Suneth Agampodi

Air contamination in the operating room (OR) is an important contributor for surgical site infections. Air quality should be assessed during microbiological commissioning of new ORs and as required thereafter. Despite many modern methods of sampling air, developing countries mostly depended on conventional methods. This was studied in two ORs of the National Hospital of Sri Lanka (NHSL) with different ventilation system; a conventional ventilation (CV) and a laminar air flow (LAF). Both ORs were sampled simultaneously by two different methods, the settle plate and sampler when empty and during use for a defined time period. Laboratory work was done in the Medical Research Institute. The two methods of sampling showed moderate but highly significant correlation. The OR with CV was significantly more contaminated than LAF when empty as well as during use by both methods. Overall, the difference in contamination was more significant when sampled by the sampler. Differences in contamination in empty and in-use ORs were significant in both ORs, but significance is less in LAF rooms. The consistent and significant correlation between settle plate and sampler showed that the settle plate is an acceptable method. The LAF theatre showed less contamination while empty and during use as expected. Air contamination differences were more significant when sampled with sampler indicating that it is a more sensitive method. Both CV and LAF ORs of the NHSL did not meet the contamination standards for empty theatres but met the standards for in-use indicating that the theatre etiquette was acceptable.


2020 ◽  
Vol 59 (2) ◽  
pp. 7-22
Author(s):  
Yu.A. Kirsanov ◽  
◽  
A.E. Yudakhin ◽  
A.Yu. Kirsanov ◽  
◽  
...  
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document