Host Guest Inclusion Complex Modified Electrode for the Sensitive Determination of a Muscle Relaxant Drug

2016 ◽  
Vol 163 (7) ◽  
pp. B403-B409 ◽  
Author(s):  
Nada F. Atta ◽  
Said S. Elkholy ◽  
Yousef M. Ahmed ◽  
Ahmed Galal
2021 ◽  
Author(s):  
Zhen Li ◽  
Tan Wang ◽  
Xianbao Xu ◽  
Cong Wang ◽  
Daoliang Li

A novel “on–off” fluorescent probe for the determination of ammonia nitrogen has been synthesized. URO can replace PAL into the cavity of CB[7] to form a stable inclusion complex, eventually forming the fluorescence quenching system of URO@CB[7].


Talanta ◽  
2017 ◽  
Vol 168 ◽  
pp. 1-9 ◽  
Author(s):  
Yamin Fu ◽  
Lu Wang ◽  
Yinghao Duan ◽  
Lina Zou ◽  
Baoxian Ye

2013 ◽  
Vol 641-642 ◽  
pp. 562-565
Author(s):  
Zheng Xiao Liu ◽  
Jian Fei Xia ◽  
Zong Hua Wang ◽  
Yan Zhi Xia ◽  
Fei Fei Zhang ◽  
...  

A novel composite was firstly synthesized by compositing graphenes (G) and carbon nanotubes (CNTs) and then a new composite modified electrode (G/CNTs/GCE) was prepared by coating the resulting composite on the surface of the glassy carbon electrode (GCE). The composite modified electrode G/CNTs/GCE showed great electrochemical activities which were studied by sensitive determining the electrochemistry behaviors of uric acid (UA). It revealed when the concentration range of UA changed from 1×10-7 mol/L to 1×10-3 mol/L, the peak currents had linear relationship with the concentration of UA in the phosphate buffer solution (PBS) which the value of pH is 7.0. And the linear equation is ip (μA) = 21.55C+28.94 (C: mmol/L), with the related coefficient 0.9964.


2013 ◽  
Vol 641-642 ◽  
pp. 566-569
Author(s):  
Feng Cai ◽  
Jian Fei Xia ◽  
Zong Hua Wang ◽  
Yan Zhi Xia ◽  
Fei Fei Zhang ◽  
...  

A novel Nafion/PMB/G/GCE was prepared by firstly electro-polymerization of MB to G/GCE and then coating Nafion on PMB/G/GCE. The as-prepared modified electrode combining the advantages of Nafion, methylene blue and G was employed for the sensitive detection of rutin. The results showed that the peak current of rutin obtained on Nafion/PMB/G/GCE was obviously high compared to bare electrode and G/GCE. Under the optimized value of pH, which was pH 3.0, peak current of rutin had good linear relation with the scan rate. At the same time, peak current increased linearly with increasing concentration of rutin. The linear range was from 5×10-7 mol/L to 1.2×10-5 mol/L, and the detection limit was 9.5×10-8 mol/L


Sign in / Sign up

Export Citation Format

Share Document