Dynamics of respiratory gas exchange during exercise after correction of congenital heart disease

1996 ◽  
Vol 80 (2) ◽  
pp. 458-463 ◽  
Author(s):  
T. Reybrouck ◽  
L. Mertens ◽  
N. Kalis ◽  
M. Weymans ◽  
M. Dumoulin ◽  
...  

In pediatric exercise testing, conventional measures of aerobic exercise function such as maximal O2 uptake or the ventilatory anaerobic threshold (VAT) use only one value for the assessment of exercise capacity. We studied a more comprehensive approach to evaluate aerobic exercise function by analyzing the steepness of the slope of CO2 production (VCO2) vs. VO2 above the VAT (S3). This was calculated in 32 patients operated on for congenital heart disease [16 for transposition of the great arteries (TGA) and 16 for tetralogy of Fallot (TF)] and was compared with 16 age-matched controls (nl). The results show that the reproducibility of this new assessment method was excellent (coefficient of variation for S3: 8.6%). S3 was significantly steeper (P<0.05) in the patients (1.31 +/- 0.22 for TGA and 1.28 +/- 0.16 for TF) compared with the nl (1.10 +/- 0.22). Also, the difference between S3 and the slope of VCO2 vs. VO2 below the VAT was significantly higher in the patients (0.37 +/- 0.22 for TGA and 0.31 +/- 0.10 for TF) than in controls (0.22 +/- 0.06). The steeper slopes were associated with lower than normal values for VAT and O2 during exercise. It is concluded that the analysis of the steepness of the slope of CO2 is a sensitive, reproducible, and objective approach to evaluate the integrative cardiopulmonary response to exercise. It complements the assessment of a subnormal VAT by reflecting the extent of anaerobic metabolism.

Circulation ◽  
2006 ◽  
Vol 113 (24) ◽  
pp. 2796-2802 ◽  
Author(s):  
Konstantinos Dimopoulos ◽  
Darlington O. Okonko ◽  
Gerhard-Paul Diller ◽  
Craig S. Broberg ◽  
Tushar V. Salukhe ◽  
...  

2021 ◽  
Vol 16 (6) ◽  
pp. 597-608
Author(s):  
Lukas Minder ◽  
Markus Schwerzmann ◽  
Thomas Radtke ◽  
Hugo Saner ◽  
Prisca Eser ◽  
...  

2021 ◽  
Vol 16 (1) ◽  
pp. 150-156
Author(s):  
Henry Wicaksono ◽  
Mahrus A Rahman ◽  
Roedi Irawan ◽  
I Ketut Alit Utamayasa ◽  
Teddy Ontoseno ◽  
...  

Background: The most common complication in acyanotic congenital heart disease (CHD) is heart failure which definitive diagnosis and therapy remain unsatisfactory. Heart failure’s progression is often associated with oxidative stress process. Superoxide dismutase (SOD) is the first line antioxidant of defense against superoxide anion. While Catalase (CAT) breaks down hydrogen peroxide into water and oxygen molecules which complements previous detoxification carried out by SOD. Objective: This study aimed to compare the differences of SOD and CAT levels in acyanotic CHD patients between those with and without heart failure. Methods: A case-control study was conducted on three to ten years old children with a left-to-right shunt acyanotic CHD with and without heart failure in the Pediatric Cardiology outpatient clinic, ward, and emergency room of Dr. Soetomo Hospital Surabaya from April-July 2020. Echocardiography was used to establish the diagnosis of CHD, while Pediatric Heart Failure Score (PHFS) criteria was used to indicate heart failure. T-test was undertaken for analysing the difference between both groups. Results: The total samples were 41 children, consisted of 29 subjects in the case group (CHD with heart failure) and 12 subjects in the control group (without heart failure). The level of SOD in CHD with heart failure was lower (74.670+15.705) than those without it (109.163+3.111) (p<0.05). In contrast, level of CAT in CHD with heart failure was higher (25.895) than those without it (13.976) (p<0.05). Conclusion: There was a significant difference of SOD and CAT levels in acyanotic CHD between those with and without heart failure.


2013 ◽  
Vol 168 (5) ◽  
pp. 4685-4691 ◽  
Author(s):  
Ana Ubeda Tikkanen ◽  
Alexander R. Opotowsky ◽  
Ami B. Bhatt ◽  
Michael J. Landzberg ◽  
Jonathan Rhodes