scholarly journals Development and Validation of RP-HPLC Method for the Determination of Adefovir Dipivoxil in Bulk and in Pharmaceutical Formulation

2009 ◽  
Vol 6 (2) ◽  
pp. 469-474 ◽  
Author(s):  
Zaheer Ahmed ◽  
B. Gopinath ◽  
A. Sathish Kumar Shetty ◽  
B. K. Sridhar

A rapid and sensitive RP-HPLC method with UV detection (262 nm) for routine analysis of adefovir dipivoxil in bulk and in pharmaceutical formulation was developed. Chromatography was performed with mobile phase containing a mixture of acetonitrile and phosphate buffer (50:50, v/v) with flow rate 1.0 mL min-l. In the range of 5.0-100 µg/mL, the linearity of adefovir dipivoxil shows a correlation co-efficient of 0.9999. The proposed method was validated by determining sensitivity accuracy, precision, robustness stability, specificity, selectivity and system suitability parameters.

Separations ◽  
2021 ◽  
Vol 8 (1) ◽  
pp. 5
Author(s):  
Mohd Afzal ◽  
Mohd. Muddassir ◽  
Abdullah Alarifi ◽  
Mohammed Tahir Ansari

A highly specific, accurate, and simple RP-HPLC technique was developed for the real-time quantification of domperidone (DOMP) and lansoprazole (LANS) in commercial formulations. Chromatographic studies were performed using a Luna C8(2), 5 μm, 100Å, column (250 × 4.6 mm, Phenomenex) with a mobile phase composed of acetonitrile/2 mM ammonium acetate (51:49 v/v), pH 6.7. The flow rate was 1 mL·min−1 with UV detection at 289 nm. Linearity was observed within the range of 4–36 µg·mL−1 for domperidone and 2–18 µg·mL−1 for lansoprazole. Method optimization was achieved using Box-Behnken design software, in which three key variables were examined, namely, the flow rate (A), the composition of the mobile phase (B), and the pH (C). The retention time (Y1 and Y3) and the peak area (Y2 and Y4) were taken as the response parameters. We observed that slight alterations in the mobile phase and the flow rate influenced the outcome, whereas the pH exerted no effect. Method validation featured various ICH parameters including linearity, limit of detection (LOD), accuracy, precision, ruggedness, robustness, stability, and system suitability. This method is potentially useful for the analysis of commercial formulations and laboratory preparations.


INDIAN DRUGS ◽  
2021 ◽  
Vol 58 (01) ◽  
pp. 35-40
Author(s):  
Rajesh Sharma ◽  
◽  
Mukesh C. Sharma ◽  
Gaurav Vijaywargiya

Chromatographic separation of paracetamol, aceclofenac and tramadol hydrochloride was performed on a Chromatopak C-18 column (25 cm x 4.6mm i.d. x 5µm) as stationary phase with a mobile phase composed of phosphate buffer pH 7.0: acetonitrile (65:35 V/V), pH 7.0 (adjusted with triethylamine) at flow rate of 1mL/min. Detection was carried out at 265 nm. The retention times of paracetamol, aceclofenac and Tramadol hydrochloride were found to be 2.7, 4.5 and 6.0 min, respectively. The proposed method was validated for linearity, accuracy, precision, LOD and LOQ. The method was found to be accurate, precise, specific, robust, and linear for the determination of paracetamol, aceclofenac and tramadol hydrochloride in pharmaceutical dosage form.


INDIAN DRUGS ◽  
2015 ◽  
Vol 52 (12) ◽  
pp. 49-55
Author(s):  
N. P Ambhore ◽  
◽  
P. M. Dandagi ◽  
A. P. Gadad ◽  
N. H. S. Reddy

The main objective of the current study was to develop a simple, accurate, precise and rapid RPHPLC method and subsequent validation using ICH suggested approach for the determination of bimatoprost in bulk and pharmaceutical dosage form. The chromatographic separation of bimatoprost was achieved on a phenomenex C18 column (150 mm × 4.6 mm; 5 μm) using PDA detector at 194 nm. The compound was separated with a mixture of acetonitrile and 0.2% triethylamine (pH 7.0 adjusted with o-phosphoric acid) in the ratio of 50:50 v/v as the optimized mobile phase at the flow rate of 1 mL/min. Chromatogram showed peak of bimatoprost at retention time of 3.8 min. The method was validated for linearity, sensitivity, precision, accuracy, system suitability and robustness. Calibrations were linear over the concentration range of 6.25-100 μg/mL as indicated by correlation coefficient (r2) of 0.999. Developed method can be applicable for routine quantitative determination of bimatoprost in pharmaceutical dosage forms.


2006 ◽  
Vol 3 (1) ◽  
pp. 60-64 ◽  
Author(s):  
P. Venkata Reddy ◽  
B. Sudha Rani ◽  
G. Srinu Babu ◽  
J. V. L. N. Seshagiri Rao

A reverse phase HPLC method is developed for the determination of Raloxifene in pharmaceutical dosage forms. Chromatography was carried out on an inertsil C18 column using a mixture of acetonitrile and phosphate buffer (30:70 v/v) as the mobile phase at a flow rate of 1 mL/min. Detection was carried out at 290 nm .The retention time of the drug was 10.609 min. The method produced linear responses in the concentration range of 0.5-200 µg/mL of Raloxifene. The method was found to be applicable for determination of the drug in tablets.


INDIAN DRUGS ◽  
2016 ◽  
Vol 53 (08) ◽  
pp. 48-52
Author(s):  
K. P Parekh ◽  
◽  
A. P. Jadhav

A simple, accurate, precise, robust stability indicating RP-HPLC method was developed and validated for simultaneous estimation of berberine and curcumin in an ayurvedic formulation. The two markers were resolved using a C-18 column using as the mobile phase methanol: water (pH 3 adjusted using acetic acid) in the ratio 75:25 V/V at a flow rate of 1mL/min. Retention times of berberine and curcumin were 2.58 ± 0.2 min and 8.5 ± 0.2 min, respectively at 358 nm. Linear response was observed in the concentration range of 2 – 8 ppm for berberine and 5 – 40 ppm for curcumin, with correlation coefficient (r2) of 0.994 and 0.998 for berberine and curcumin, respectively. The developed method was applied for quantitation of markers in marketed and in-house formulations of Gruhadhoomadi Churna. This method can also be used to evaluate formulations containing berberine and curcumin as markers, thus conforming to the need of ensuring quality and safety of herbal medicines.


Author(s):  
Sonalika Patro ◽  
S. Harshith Kumar ◽  
M. Barath kumar ◽  
E. Masthaniah ◽  
K. Sairam ◽  
...  

A Simple, accurate and precise method was developed and validated for the determination of flucloxacillin sodium in its tablet dosage form. The separation was eluted on xterra c18 column (4.6x150mm, 5micron) using a mixture of octane buffer and methanol as mobile phase in a ratio of (30:70) which was pumped through column at a flow rate of  1ml/min. Optimised wavelength for flucloxacillin was 237nm, the retention time was 2.305minutes and the percentage purity was found to be 98.14%. System suitability parameters such as theoretical plate and tailing factor for flucloxacillin sodium was found to be 2991.64 and 1.90 respectively, the proposed method was validated as per ICH guidelines (ICH, Q2 AND (R1)) the method was found to be linear at the concentration range of 20-100µg/ml and the correlation coefficient (r2) value was found to be 0.9994 percentage RSD for precision was 0.9% and percentage RSD for ruggedness was 0.5%. The precision study was precise, robust and repeatable. The LOD and LOQ values are 2.98 and 9.98 respectively. Hence the suggested RP-HPLC method can be used for routine analysis for flucloxacillin sodium in tablet dosage form.


2021 ◽  
Vol 37 (02) ◽  
pp. 493-498
Author(s):  
Mohan Bhatale ◽  
Neelakandan Kaliyaperumal ◽  
Gopalakrishnan Mannathusamy ◽  
Gurunathan Ramalingam

A simple, selective, linear having accuracy and specific of reverse phase high-performance liquid chromatographic (RP-HPLC) method for determination of Genotoxic impurity Hydroxylamine Hydrochloride of drug Leflunomide is reported.The separation and analysis were done on YMC Triart C18 (4.6 mm x 150 mm), having particle size 3.0 μm. KH2PO4 in 2000 mL of purified water and 2 mL triethylamine with pH 2.5 with phosphoric acid is mobile phase-A while acetonitrile is mobile Phase-B with gradient program. The elution achieved with 1.50 mL/min flow rate and using UV detection at 230 nm wavelength. Selected column oven temperature is 45°C and auto sampler 5°C respectively. In this method linearity and accuracy of Hydroxylamine HCl covered with specification limit of LOQ to 150 % (i.e.3 to 23 ppm). The observed correlation coefficient is 0.99965 and recovery in between 99.07 to 114.94. In method precision (ie.repeatability) and intermediate precision (IP) observed % RSD of six spiked test preparation is below 5.0 %. The standard and sample were stable for 3 days when stored at 2 to 8°C temperature. In robustness studies system suitability parameters ie tailing factor, theoretical plates and %RSD does not show significant changes. The present RP-HPLC method is selective, robust, linear, and precise for detection of Hydroxylamine HCl.


Author(s):  
M Lakshmi Kanth ◽  
B Raj Kama

An accurate RP-HPLC method developed for the estimation of Neratinib in bulk and tablet dosage form. The method is and validated for parameters linearity, accuracy, suitability, specificity, precession, LOD, LOQ and robustness. An Altima column (150 mm × 4.6 mm × 5μ) used for chromatographic separation within a runtime of 6 min. The mobile phase buffer (monopotassium phosphate) and acetonitrile (60:40 v/v) with 0.1% formic acid is used. The flow rate maintained at 1.0 ml/min with the effluents monitored at 215 nm. The Neratinib analyzed at retention time of 4.001. The concentration linear over 30-180μg/ml with regression equation y = 6065.6x + 795.43 and regression co-efficient 0.999.