A highly specific, accurate, and simple RP-HPLC technique was developed for the real-time quantification of domperidone (DOMP) and lansoprazole (LANS) in commercial formulations. Chromatographic studies were performed using a Luna C8(2), 5 μm, 100Å, column (250 × 4.6 mm, Phenomenex) with a mobile phase composed of acetonitrile/2 mM ammonium acetate (51:49 v/v), pH 6.7. The flow rate was 1 mL·min−1 with UV detection at 289 nm. Linearity was observed within the range of 4–36 µg·mL−1 for domperidone and 2–18 µg·mL−1 for lansoprazole. Method optimization was achieved using Box-Behnken design software, in which three key variables were examined, namely, the flow rate (A), the composition of the mobile phase (B), and the pH (C). The retention time (Y1 and Y3) and the peak area (Y2 and Y4) were taken as the response parameters. We observed that slight alterations in the mobile phase and the flow rate influenced the outcome, whereas the pH exerted no effect. Method validation featured various ICH parameters including linearity, limit of detection (LOD), accuracy, precision, ruggedness, robustness, stability, and system suitability. This method is potentially useful for the analysis of commercial formulations and laboratory preparations.

2009 ◽  
Vol 6 (2) ◽  
pp. 469-474 ◽  
Author(s):  
Zaheer Ahmed ◽  
B. Gopinath ◽  
A. Sathish Kumar Shetty ◽  
B. K. Sridhar

A rapid and sensitive RP-HPLC method with UV detection (262 nm) for routine analysis of adefovir dipivoxil in bulk and in pharmaceutical formulation was developed. Chromatography was performed with mobile phase containing a mixture of acetonitrile and phosphate buffer (50:50, v/v) with flow rate 1.0 mL min-l. In the range of 5.0-100 µg/mL, the linearity of adefovir dipivoxil shows a correlation co-efficient of 0.9999. The proposed method was validated by determining sensitivity accuracy, precision, robustness stability, specificity, selectivity and system suitability parameters.


Author(s):  
SYED IBRAHIM BAJE ◽  
B. JYOTHI ◽  
N. MADHAVI

Objective: The objective of the present study was to develop and validate a novel reverse phase high performance liquid chromatographic (RP-HPLC) method, for simultaneous determination of ritonavir (RIT), ombitasvir (OMB) and paritaprevir (PAR) in bulk mixtures, and in tablets. Methods: Determination of the drugs ritonavir (RIT), ombitasvir (OMB), and paritaprevir (PAR), was carried out applying Hypersil BDS C18 column (250 mm X 4.6 mm i.e., 5 µm particle size), with photodiode array detector at λmax of 254 nm. The mobile phase applied for the current study composed of two solvents, i.e. A (0.01N % w/v potassium di-hydrogen orthophosphate buffer, pH 3.0 adjusted with dilute orthophosphoric acid) and B (acetonitrile). The mobile phase was pumped at a flow rate of 1.0 ml/min in the isocratic mode. The validation study with respect to specificity, linearity, precision, accuracy, and robustness, limit of detection (LOD) and limit of quantification (LOQ) was carried out employing the ICH guidelines. Results: Ritonavir, ombitasvir, and paritaprevir showed linearity of response between 12.5-75 μg/ml for ritonavir, 3.125-18.75 µg/ml for ombitasvir and 18.75–112.5 µg/ml for paritaprevir, with a correlation coefficient (R2) 0.999, 0.999,0.999 for RIT, OMB, and PAR respectively. The % recovery obtained was 99.82±0.14 % RIT, OMB 100.03±0.96 % and for 99.96±0.26 % PAR. The LOD and LOQ values for RIT, OMB, PAR were obtained to be 0.02, 0.019and0.02, µg/ml and 0.07, 0.06 and 0.07 µg/ml, respectively. The method also exhibits good robustness for different chromatographic conditions like wavelength, flow rate, mobile phase, and injection volume. Conclusion: The method was successfully employed, for the quantification of RIT, OMB, and PAR, in the quality control of in-house developed tablets, and can be applied for the industrial use.


2018 ◽  
Vol 17 (1) ◽  
pp. 43-50
Author(s):  
Sherejad Sanam ◽  
Sharmin Nahar ◽  
Nazmus Saqueeb ◽  
SM Abdur Rahman

A stability indicating HPLC method was developed and validated for the quantitative determination of fexofenadine hydrochloride. An isocratic separation was achieved using phenomenex (C18) column (250×4.6 mm, 5 μm) with flow rate of 1.0 ml/min and UV detection at 254 nm. The mobile phase consists of 5Mm acetate buffer: acetonitrile (50:50; v/v) with pH 9.4 adjusted with acetic acid. The drug was subjected to oxidative, acidic, basic, neutral, photolytic and thermal degradation. All degradation products were eluted in an overall analytical run time of approximately 40 min with the parent compound fexofenadine hydrochloride at a flow rate of approximately 3.3±0.3 min. The method was linear over the concentration range of 31.5-500 μg/ml (r2 = 0.999) with limit of detection and quantification of 3.5 μg/ml and 10.1 μg/ml, respectively. The method has the requisite accuracy, selective, precision and robustness to assay fexofenadine HCl in tablets.Dhaka Univ. J. Pharm. Sci. 17(1): 43-50, 2018 (June)


2006 ◽  
Vol 3 (1) ◽  
pp. 60-64 ◽  
Author(s):  
P. Venkata Reddy ◽  
B. Sudha Rani ◽  
G. Srinu Babu ◽  
J. V. L. N. Seshagiri Rao

A reverse phase HPLC method is developed for the determination of Raloxifene in pharmaceutical dosage forms. Chromatography was carried out on an inertsil C18 column using a mixture of acetonitrile and phosphate buffer (30:70 v/v) as the mobile phase at a flow rate of 1 mL/min. Detection was carried out at 290 nm .The retention time of the drug was 10.609 min. The method produced linear responses in the concentration range of 0.5-200 µg/mL of Raloxifene. The method was found to be applicable for determination of the drug in tablets.


Author(s):  
Sonalika Patro ◽  
S. Harshith Kumar ◽  
M. Barath kumar ◽  
E. Masthaniah ◽  
K. Sairam ◽  
...  

A Simple, accurate and precise method was developed and validated for the determination of flucloxacillin sodium in its tablet dosage form. The separation was eluted on xterra c18 column (4.6x150mm, 5micron) using a mixture of octane buffer and methanol as mobile phase in a ratio of (30:70) which was pumped through column at a flow rate of  1ml/min. Optimised wavelength for flucloxacillin was 237nm, the retention time was 2.305minutes and the percentage purity was found to be 98.14%. System suitability parameters such as theoretical plate and tailing factor for flucloxacillin sodium was found to be 2991.64 and 1.90 respectively, the proposed method was validated as per ICH guidelines (ICH, Q2 AND (R1)) the method was found to be linear at the concentration range of 20-100µg/ml and the correlation coefficient (r2) value was found to be 0.9994 percentage RSD for precision was 0.9% and percentage RSD for ruggedness was 0.5%. The precision study was precise, robust and repeatable. The LOD and LOQ values are 2.98 and 9.98 respectively. Hence the suggested RP-HPLC method can be used for routine analysis for flucloxacillin sodium in tablet dosage form.


2019 ◽  
Vol 70 (2) ◽  
pp. 487-490
Author(s):  
Nicolae Avram ◽  
Simona Codruta Heghes ◽  
Luca-Liviu Rus ◽  
Anca Maria Juncan ◽  
Lucia Maria Rus ◽  
...  

A HPLC-UV method, for determination of dextromethorphan hydrobromide in syrup, was validated. The chromatographic analysis was performed using an RP-18, Nucleodur chromatographic column (250 mm � 4 mm, 5 �m) at constant temperature (50oC) with a mobile phase consisting of a mixture of acetonitrile/methanol (70:30 v/v) with sodium docusate (as ion pair agent) and ammonium nitrate, pH = 3.4. The flow rate of the mobile phase was 1 mL/min and the detection was carried out at 280 nm. System suitability, specificity, linearity, precision, accuracy, limit of detection and limit of quantification agreed with current pharmacopeial requests. The method is suitable for routine analysis of dextromethorphan hydrobromide in syrup.


Author(s):  
NOVALINA BR PURBA ◽  
ABDUL ROHMAN ◽  
SUDIBYO MARTONO

Objective: The objective of this study was to optimize high-performance liquid chromatography (HPLC) method for the determination of acid orange 7 (AO7) and sudan II (SII) in blusher product based on response surface methodology using box behnken design (BBD) approach. Methods: Some factors responsible for HPLC separation including column temperature, mobile phase composition, flow rate were optimized using BBD. The responses evaluated were peak area, retention time, and tailing factor. AO7 and SII in blusher product has different properties, therefore both analytes were analysed using C18 column (Thermo Synergy Gold 250 mm x 4.6 mm i.d.,5 µm) using Shimadzu LC 20AD chromatograph equipped with photo-diode array (PDA) detector at 300-650 nm. The mobile phase used was acetonitrile-water (1:1 v/v), and acetonitrile composition was optimized at 35-50% for separation AO7 (ACN1), and 80-90% for SII (ACN2), delivered at the flow rate of 0.9–1 ml/min, using column temperature at 30-40 °C. Results: BBD showed that separation of AO7 was influenced by the concentration of ACN1, flow rate and column temperature. These factors affected retention time, peak area, and tailing factor with peak area was the most significant. Tailing factor was not significantly affected by each factor, and retention time was slightly effected. Otherwise, Sudan II was affected by all these factors except ACN1. The optimal condition obtained based BBD was ACN1 43%, ACN2 90%, the flow rate of 0.9 ml/min and a column temperature of 40 °C. Conclusion: BBD can be used to get optimum condition for analysis of AO7 and SII in blusher product.


2009 ◽  
Vol 6 (4) ◽  
pp. 1188-1192 ◽  
Author(s):  
G. Rathinavel ◽  
U. Uma Nath ◽  
J. Valarmathy ◽  
L. Samueljoshua ◽  
C. Selvin Thanuja ◽  
...  

A reverse phase HPLC method is described for the determination of rosiglitazone and gliclazide in tablet dosage form. Chromatography was carried on Phenomenix Gemini C18column using in mixture of ammonium phosphate buffer, Acetonitrile and methanol in the ratio 50: 35: 15 v/v as mobile phase at a flow rate 1 mL min-1and the effluent was monitored at 254 nm. The retention time for rosiglitazone was 3.74 and gliclazide 7.84 min. The limit of detection for rosiglitazone was 4.07μg/mL and gliclazide 1.19 μg/mL. The LOQ obtained for rosiglitazone was 12.33 μg/mL and 3.612 μg/mL. The percentage assay for rosiglitazone was 99.92% and gliclazide was 99.82%. The method was validated for accuracy precision and system suitability. The proposed method was fast accurate and precise so it can be used for regular quality control of the drug.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Hina Shamshad ◽  
Agha Zeeshan Mirza

Abstract Background Present work describes a fast, simple, and sensitive procedure for the simultaneous determination of cetirizine in the presence of quinolones using diclofenac sodium as an internal standard. The present work was designed to analyze these compounds in pharmaceutical and clinical labs being economical for use. Results The mobile phase consisted of the simple composition of methanol, acetonitrile, and water in a ratio of 50:20:30 with a pH adjusted to 3.1 at a flow rate of 1 mL min−1. The UV detection was performed at 225 nm. The linearity was assessed over the range of 2.5–50 μg mL−1 for all drugs. The parameters such as accuracy, precision, linearity (>0.999), and sensitivity were satisfactory. Conclusion The method was equally applicable for formulation and human serum with recovery values between 95 and 105%. The results of the method were validated statistically according to ICH guidelines.


2020 ◽  
Vol 66 (1) ◽  
pp. 85-90
Author(s):  
Zhaklina Poposka Svirkova ◽  
Zorica Arsova-Sarafinovska ◽  
Aleksandra Grozdanova

Due to the low absorptivity of bile acids, the aim of this study was to develop and validate a simple and sensitive HPLC/UV method for quantification of ursodeoxycholic acid (UDCA) in pharmaceutical formulations. Effective separation was achieved on C18 end–capped column, with gradient elution of a mobile phase composed of 0.001 M phosphate buffer (pH 2.8±0.5) – acetonitrile mix, at flow rate 1.5 mL min-1, UV detection at 200 nm and injection volumes were 50 µL. The proposed HPLC method was fully validated according to the ICH guidelines and it was found to be simple, accurate, precise and robust. Key words: ursodeoxycholic acid, HPLC/UV, pharmaceutical formulations, validation