scholarly journals Comparison of Anterior Segment Measurements with Scheimpflug/Placido Photography-Based Topography System and IOLMaster Partial Coherence Interferometry in Patients with Cataracts

2014 ◽  
Vol 2014 ◽  
pp. 1-6 ◽  
Author(s):  
Jinhai Huang ◽  
Na Liao ◽  
Giacomo Savini ◽  
Fangjun Bao ◽  
Ye Yu ◽  
...  

Purpose. To assess the consistency of anterior segment measurements obtained using a Sirius Scheimpflug/Placido photography-based topography system (CSO, Italy) and IOLMaster partial coherence interferometry (Carl Zeiss Meditec, Germany) in eyes with cataracts.Methods. A total of 90 eyes of 90 patients were included in this prospective study. The anterior chamber depth (ACD), keratometry (K), corneal astigmatism axis, and white to white (WTW) values were randomly measured three times with Sirius and IOLMaster. Concordance between them was assessed by calculating 95% limits of agreement (LoA).Results. The ACD and K taken with the Sirius were statistically significantly higher than that taken with the IOLMaster; however, the Sirius significantly underestimated the WTW values compared with the IOLMaster. Good agreement was found for Km and ACD measurements, with 95% LoA of −0.20 to 0.54 mm and −0.16 to 0.34 mm, respectively. Poor agreement was observed for astigmatism axis and WTW measurements, as the 95% LoA was −23.96 to 23.36° and −1.15 to 0.37 mm, respectively.Conclusion. With the exception of astigmatism axis and WTW, anterior segment measurements taken by Sirius and IOLMaster devices showed good agreement and may be used interchangeably in patients with cataracts.

2016 ◽  
Vol 2016 ◽  
pp. 1-5
Author(s):  
Jinhai Huang ◽  
Weicong Lu ◽  
Giacomo Savini ◽  
Hao Chen ◽  
Chengfang Wang ◽  
...  

Purpose.To compare between a new optical biometer (AL-Scan, Nidek Co., Aichi, Japan) and an anterior segment optical coherence tomographer (Visante AS-OCT, Carl Zeiss Meditec, Dublin, USA) for measuring central corneal thickness (CCT), anterior chamber depth (ACD), and aqueous depth (AD).Methods.Sixty-three eyes of 63 normal subjects were examined with AL-Scan and Visante AS-OCT in this prospective study. One eye per subject was measured three times with both devices to record their CCT, ACD, and AD. All procedures were performed by the same operator. Agreement between the two devices was assessed using pairedt-tests, Bland-Altman plots, and 95% limits of agreement (LoA).Results.The mean CCT, ACD, and AD measured by AL-Scan were538.59±27.37 μm,3.70±0.30 mm, and3.16±0.30 mm, respectively. The mean values obtained by the Visante OCT were536.14±26.61 μm for CCT,3.71±0.29 mm for ACD, and3.17±0.29 mm for AD. The mean CCT by the AL-Scan was higher than that obtained by the Visante AS-OCT (difference =2.45±6.07 μm,P<0.05). The differences in ACD and AD measurements were not statistically significant. The 95% LoA of CCT, ACD, and AD were between −9.44 and 14.35 μm, −0.15 and 0.12 mm, and −0.15 and 0.12 mm, respectively.Conclusions.Since these two devices were comparable for measuring CCT, ACD, and AD, their results can be interchangeably used in the clinic.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Domenico Schiano-Lomoriello ◽  
Kenneth J. Hoffer ◽  
Irene Abicca ◽  
Giacomo Savini

AbstractWe assess repeatability of automatic measurements of a new anterior segment optical coherence tomographer and biometer (ANTERION) and their agreement with those provided by an anterior segment-optical coherence tomography device combined with Placido-disk corneal topography (MS-39) and a validated optical biometer (IOLMaster 500). A consecutive series of patients underwent three measurements with ANTERION and one with MS-39. A subgroup of patients underwent biometry also with IOLMaster 500. Repeatability was assessed by means of within-subject standard deviation, coefficient of variation (COV), and intraclass correlation coefficient (ICC). Agreement was investigated with the 95% limits of agreement. Paired t-test and Wilcoxon matched-pairs test were performed to compare the measurements of the different devices. Repeatability of ANTERION measurements was high, with ICC > 0.98 for all parameters except astigmatism (0.963); all parameters apart from those related to astigmatism revealed a COV < 1%. Repeatability of astigmatism improved when only eyes whose keratometric astigmatism was higher than 1.0 D were investigated. Most measurements by ANTERION and MS-39 showed good agreement. No significant differences were found between measurements by ANTERION and IOLMaster, but for corneal diameter. ANTERION revealed high repeatability of automatic measurements and good agreement with both MS-39 and IOLMaster for most parameters.


Author(s):  
Alireza Khodabande ◽  
Massood Mohammadi ◽  
Hamid Riazi-Esfahani ◽  
Shahab Karami ◽  
Massood Mirghorbani ◽  
...  

Abstract Background To evaluate changes in anterior segment morphology on anterior segment optical coherence tomography (AS-OCT) following pars plana vitrectomy (PPV) without tamponade. Methods Patients who underwent PPV without tamponade for epiretinal membrane were evaluated. Eligible patients underwent intraocular pressure (IOP) measurement and AS-OCT preoperatively as well as 1 month and 6 months post-operatively. Anterior chamber width (ACW), anterior chamber depth (ACD), trabecular iris angle (TIA), angle opening distance at 500 and 750 µm (AOD), and trabecular iris space area at 500 and 750 µm (TISA) at four quadrants were recorded and analyzed. Additionally, the mean values of TIA (MTIA), AOD (MAOD), and TISA (MTISA) for each eye (mean of four quadrants) were analyzed. Results 23 patients completed the study. The mean age of participants was 56.4 ± 3.6 years of age and 13/23 (56%) were female. Mean IOP of patients was 18.1 ± 1.1, 18.3 ± 1.1, and 18.1 ± 1.2 preoperatively,1 month post-operatively, and 6 months post-operatively, respectively. (p = 0.83). No difference was detected post-operatively in measurements of ACW, ACD, MTIA, MAOD500, MAOD750, MTISA500, and MTISA750. Conclusion Pars plana vitrectomy without tamponade was not associated with changes in anterior chamber morphology.


2021 ◽  
pp. 112067212110393
Author(s):  
Murat Hasanreisoglu ◽  
Cem Kesim ◽  
Duygu Yalinbas ◽  
Mervenur Yilmaz ◽  
Nur Sena Uzunay ◽  
...  

Background: To evaluate effect of maximal anterior cortical lens density, iris scatter and anterior chamber depth on laser flare photometry. Methods: Patients diagnosed with clinical uveitis were enrolled in the study. Clinical flare gradings were recorded upon the Standardization of Uveitis Nomenclature. Aqueous flare was measured with an automated device (Kowa FM-700). Back-scattering from anterior cortical lens and anterior iris surface was calculated from Scheimpflug images. A curvilinear regression model was used to calculate estimated values for each clinical grade. These values were used to split cases in Group I (laser flare photometry lower than estimated) and Group II (laser flare photometry higher than estimated). Mean anterior chamber depth, pupil aperture, maximal anterior cortical lens density and iris scatter values were compared between two groups. A stepwise multiple regression analysis was performed to determine the effect of clinical flare gradings and ocular parameters on aqueous flare measurements. Results: The study included 228 eyes of 114 cases. Scheimpflug images were obtained from 105 eyes. Estimated aqueous flare measurements (in photons/milliseconds) were 4.87, 8.50, 14.81, 25.83, 45.04 and 136.93 for 0, 0.5+, 1+, 1.5+, 2+ and 3+ clinical flare respectively. Group II had higher maximal anterior cortical lens density than Group I (96.6 ± 37.1 vs 77.9 ± 17.1 pixel unit, p = 0.001). The measured aqueous flare was significantly related to clinical flare, maximal anterior cortical lens density and pupil aperture (adjusted R2: 0.480, p < 0.001). Conclusion: The back-scattered light from anterior cortical lens could affect laser flare photometry measurements. This effect might be quantified by Scheimpflug imaging.


2022 ◽  
Author(s):  
Mahmoud Ekram ◽  
Ahmed Mohamed Kamal Elshafei ◽  
Asmaa Anwar Mohamed ◽  
Mohamed Farouk Sayed Othman Abdelkader

Abstract Purpose: To evaluate the anatomical effects of implantable phakic contact lens (IPCL) (Care Group, India) on anterior segment and its visual outcomes .Patients and methods: In a prospective interventional case series study, 60 highly myopic eyes of 32 patients were subjected to IPCL implantation in the Ophthalmology Department of Minia University Hospital, Egypt from January 2019 to June 2021. All patients had complete ophthalmic examination and were followed up for 1 year. Pentacam was used for preoperative and postoperative estimation of anterior chamber depth (ACD), anterior chamber angle (ACA), anterior chamber volume (ACV) and IPCL vault in the 1st, 3rd, and 12th months. Assessment of corneal endothelium was done using specular microscope preoperatively and after 12 months. Preoperative and postoperative refraction and visual acuity were measured. Results: There was a statistically significant decrease in ACD, ACA, and ACV. There was no significant difference between preoperative and postoperative mean intraocular pressure (IOP) by the 12th month (P=0.163). The mean preoperative endothelial cell count (ECD) was significantly reduced from 2929.3±248 cells/mm2 to 2737.9±303 cells/mm2 at the 12th month (P<0.001). with a statistically highly significant improvement of mean Log Mar uncorrected visual acuity (UCVA) from 1.48±0.19 preoperatively to 0.46±0.11 by the end of follow up (P<0.001) with insignificant difference between preoperative best corrected visual acuity (BCVA) and postoperative UCVA (P=0.209). In the 12th month, the mean vault was 240±540 μm. No sight threatening complications occurred.Conclusion: Although IPCL induced anatomical changes, it was safe and effective for correction of high myopia.


2018 ◽  
Vol 2018 ◽  
pp. 1-4
Author(s):  
Ertuğrul Tan Yassa ◽  
Cihan Ünlü

Purpose. We aimed to investigate whether anterior chamber angle, depth, and volume change after myopic laser-assisted in situ keratomileusis (LASIK) in young patients. Methods. This retrospective study included 29 eyes of 29 patients (15 females and 14 males) between the ages of 18 and 39 years who underwent LASIK for the treatment of myopia. In addition to complete ophthalmic examination, anterior chamber angle (ACA), central anterior chamber depth (ACD), and anterior chamber volume (ACV) were measured by using a Sirius rotating Scheimpflug camera combined with Placido disc corneal topography (CSO, Florence, Italy). Preoperative and postoperative values were compared using paired t-tests. Linear regression was used to evaluate the relationship between changes in refraction and changes in ACA, ACD, and ACV as well as between attempted maximum ablation depth and changes in ACA, ACD, and ACV. Results. The mean age of the study population was 25.5 ± 6.2 years. The mean preoperative and postoperative spherical equivalent values were −3.30 ± 1.92 D and −0.18 ± 0.29 D, respectively. ACV and ACA were not significantly changed after surgery; however, central ACD was significantly decreased (preoperatively = 3.366 ± 0.316 mm vs postoperatively = 3.3 ± 0.298 mm) with a mean difference of 0.066 ± 1.121 mm. There were no significant relationships between changes in refraction and anterior segment dimensions or between attempted maximum ablation depth and anterior segment dimensions. Conclusion. Measurements with Sirius showed that ACA and ACV did not change; however, central ACD significantly decreased after myopic LASIK in young patients, indicating that the preoperative central ACD value should not be used interchangeably with the postoperative central ACD value.