scholarly journals Agreement and relationship between ultrasonic and partial coherence interferometry measurements of axial length and anterior chamber depth

2012 ◽  
pp. 193
Author(s):  
Sherein Wahba
2014 ◽  
Vol 2014 ◽  
pp. 1-6 ◽  
Author(s):  
Jinhai Huang ◽  
Na Liao ◽  
Giacomo Savini ◽  
Fangjun Bao ◽  
Ye Yu ◽  
...  

Purpose. To assess the consistency of anterior segment measurements obtained using a Sirius Scheimpflug/Placido photography-based topography system (CSO, Italy) and IOLMaster partial coherence interferometry (Carl Zeiss Meditec, Germany) in eyes with cataracts.Methods. A total of 90 eyes of 90 patients were included in this prospective study. The anterior chamber depth (ACD), keratometry (K), corneal astigmatism axis, and white to white (WTW) values were randomly measured three times with Sirius and IOLMaster. Concordance between them was assessed by calculating 95% limits of agreement (LoA).Results. The ACD and K taken with the Sirius were statistically significantly higher than that taken with the IOLMaster; however, the Sirius significantly underestimated the WTW values compared with the IOLMaster. Good agreement was found for Km and ACD measurements, with 95% LoA of −0.20 to 0.54 mm and −0.16 to 0.34 mm, respectively. Poor agreement was observed for astigmatism axis and WTW measurements, as the 95% LoA was −23.96 to 23.36° and −1.15 to 0.37 mm, respectively.Conclusion. With the exception of astigmatism axis and WTW, anterior segment measurements taken by Sirius and IOLMaster devices showed good agreement and may be used interchangeably in patients with cataracts.


Author(s):  
Matthias Fuest ◽  
Niklas Plange ◽  
David Kuerten ◽  
Hannah Schellhase ◽  
Babac A. E. Mazinani ◽  
...  

Abstract Purpose We assessed the accuracy of lens power calculation in highly myopic patients implanting plus and minus intraocular lenses (IOL). Methods We included 58 consecutive, myopic eyes with an axial length (AL) > 26.0 mm, undergoing phacoemulsification and IOL implantation following biometry using the IOLMaster 500. For lens power calculation, the Haigis formula was used in all cases. For comparison, refraction was back-calculated using the Barrett Universal II (Barrett), Holladay I, Hill-RBF (RBF) and SRK/T formulae. Results The mean axial length was 30.17 ± 2.67 mm. Barrett (80%), Haigis (87%) and RBF (82%) showed comparable numbers of IOLs within 1 diopter (D) of target refraction. Visual acuity (BSCVA) improved (p < 0.001) from 0.60 ± 0.35 to 0.29 ± 0.29 logMAR (> 28-days postsurgery). The median absolute error (MedAE) of Barrett 0.49 D, Haigis 0.38, RBF 0.44 and SRK/T 0.44 did not differ. The MedAE of Haigis was significantly smaller than Holladay (0.75 D; p = 0.01). All median postoperative refractive errors (MedRE) differed significantly with the exception of Haigis to SRK/T (p = 0.6): Barrett − 0.33 D, Haigis 0.25, Holladay 0.63, RBF 0.04 and SRK/T 0.13. Barrett, Haigis, Holladay and RBF showed a tendency for higher MedAEs in their minus compared to plus IOLs, which only reached significance for SRK/T (p = 0.001). Barrett (p < 0.001) and RBF (p = 0.04) showed myopic, SRK/T (p = 002) a hyperopic shift in their minus IOLs. Conclusions In highly myopic patients, the accuracies of Barrett, Haigis and RBF were comparable with a tendency for higher MedAEs in minus IOLs. Barrett and RBF showed myopic, SRK/T a hyperopic shift in their minus IOLs.


2020 ◽  
Vol 1 (3) ◽  
pp. 166-172
Author(s):  
Rita Dhamankar ◽  
◽  
Suhas S Haldipurkar ◽  
Tanvi Haldipurkar ◽  
Vijay Shetty ◽  
...  

AIM: To assess the changes in anterior chamber parameters and examine the factors associated with changes in the intraocular pressure (IOP) in individuals who have undergone phacoemulsification surgery. METHODS: It is a longitudinal analysis of secondary clinical data collected from 105 non-glaucomatous eyes (82 patients) undergoing a cataract surgery. We studied the association between anterior chamber parameters, grade of cataract, demographics, and changes in the IOP over a period of three weeks. We also evaluated the association between the pressure-depth (PD) ratio and changes in the IOP during this time. RESULTS: The mean age (SD) of the 82 patients was 60.1±7.8y. The mean±standard deviation (SD) IOP was 15.06±3.36 mm Hg pre-operatively; it increased to 15.75±4.21 mm Hg on day one (P=0.20). In the multifactorial models, the mean IOP was -1.715 (95%CI: -2.795, -0.636) mm Hg on day 21±5 compared with the pre-operative values. The anterior chamber depth (ACD), axial length, age, sex, and grade of cataract were not significantly associated with changes in the IOP. Each unit increase in the PD ratio was associated with an increase in the mean IOP by 1.289 mm Hg (95%CI: 0.906, 1.671). After adjusting for pre-operative PD ratio, none of the other variables (ACD, axial length, temporal angle) were significantly associated with changes in mean IOP. CONCLUSION: The PD ratio was the single most important factor associated with the changes in post-operative IOP over three weeks post-surgery.


2021 ◽  
Author(s):  
Qiong Lei ◽  
Haixia Tu ◽  
Xi Feng ◽  
Yong Wang

Abstract Background: To create an anterior chamber depth (ACD) regression model for adult cataract surgery candidates from China, and to evaluate the distribution of their ocular biometric parameters.Methods: The ocular biometric records of 28,709 right eyes of cataract surgery candidates who were treated at Aier Eye Hospitals in nine cities from 2018 to 2019 were retrospectively analyzed. All measurements were taken with IOLMaster 700. We included patients who were at least 40 years old and were diagnosed with cataract.Results: The mean age of the patients was 68.6 ± 11.0 years. The mean values recorded were as follows: axial length (AL), 24.17 ± 2.47 mm; mean keratometry (Km) value, 44.09 ± 3.25 D; corneal astigmatism (CA), 1.06 ± 0.98 D; ACD, 3.02 ± 0.45 mm; lens thickness (LT), 4.52 ± 0.45 mm; central corneal thickness (CCT), 0.534 ± 0.04 mm; and white to white (WTW) corneal diameter, 11.64 ± 0.46 mm. The proportion of patients with long axial length (AL >25 mm) decreased with age. ACD, LT, AL, Km, WTW, and age were correlated. In the multivariate regression analysis of ACD, which included LT, AL, WTW, sex, Km, CCT, and age, there was a reasonable prediction with adjusted R2 = 0.629.Conclusions: The results show that high myopes are inclined to schedule cataract surgery at a younger age. LT and AL were found to be important factors that affect ACD. This study provides reference data for cataract patients from China.


Author(s):  
Feride Tuncer Orhan ◽  
Haluk Huseyin Gürsoy

Aim To evaluate consecutive measurements of the biometric parameters, age, and refraction error in a Turkish population at primary school age. Materials and Methods A total of 197 children aged between 7-12 years were included. The data of three consecutive measurements of children, who were examined at least once a year for three years using both cycloplegic auto-refractometry and optical biometry, were used in this retrospective study. Spherical equivalent <-0.50D was considered to be myopic; >+0.75D was considered to be hypermetropic. Age, gender, body mass index, spherical equivalent, axial length, anterior chamber depth, central corneal thickness, keratometry, and lens thickness were analyzed. The onset data obtained in 2013 whereas, the final data were from 2015. Logistic and Cox regression analyses were performed (p<0.05). Results The mean of the onset and the final spherical equivalents were 0.19D (0.56), and 0.08D (0.80), respectively. The myopia prevalence was increased among refractive errors in observation periods (univariable analysis p=0.029; multivariable analysis p=0.017). The onset axial length (HR:4.55, 95%CI:2.87-7.24, p<0.001), keratometry (HR:2.04, 95%CI:1.55-2.67, p<0.001) and age (HR:0.73, 95%CI: 0.57-0.92, p=0.009) correlated myopia progression. To calculate the estimated spherical equivalent, the onset data were included in the logistic regression model. The onset data of spherical equivalent (β=0.916, p<0.001), axial length (β=-0.451, p<0.001), anterior chamber depth (β=0.430, p=0.005) and keratometry (β=-0.172, p<0.001) were found to be significantly associated with the mean SE at the final data. Conclusions To calculate the estimated spherical equivalent following three years, an equation was proposed. The estimated refractive error of children can be calculated by using the proposed equation with the associated onset optical parameters.


Sign in / Sign up

Export Citation Format

Share Document