scholarly journals Kinematics and Mechanical Properties of Knees following Patellar Replacing and Patellar Retaining Total Knee Arthroplasty

2015 ◽  
Vol 2015 ◽  
pp. 1-10 ◽  
Author(s):  
Rongying Huang ◽  
Yanqiang Liu ◽  
Jun Zhu

Knee injury is a common medical issue. A full understanding of the kinematics and mechanical properties of knees following total knee arthroplasty (TKA) repair utilizing patellar replacement (only the base of the patella is replaced) versus patellar retaining surgical techniques is still lacking. In the current paper, we investigated magnetic resonance (MR) imaging data from knees repaired by these two methods and evaluated total knee models created using imaging reconstruction technology that simulated gait conditions. Results revealed that patellar replacement had little influence on tibiofemoral kinematics, although the tibia-surface equivalent stress increased slightly. By contrast, patellar replacement had a significant influence on the patellofemoral joint; patellar internal rotation, external rotation, and medial-lateral translation were all increased. Moreover, the stress distribution on patellar prostheses was altered, resulting in an increased surface maximal equivalent stress on the corresponding area. Moreover, during the gait cycle, we found that the area with maximal equivalent stress shifted its position. Finally, the patellofemoral joint showed decreased motion stability. From the view of kinematics and mechanics, this paper suggests that patella should be retained during TKA if it is possible. The present study presented approaches and technologies for evaluating kinematics and mechanical properties of total knee joint after TKA under gait loads.

2020 ◽  
Vol 79 (Suppl 1) ◽  
pp. 807.3-807
Author(s):  
I. Moriyama

Background:No widely accepted view or criteria currently exist concerning whether or not patellar replacement (resurfacing) should accompany total knee arthroplasty for osteoarthritis of the knee.1)2)3)Objectives:We recently devised our own criteria for application of patellar replacement and performed selective patellar replacement in accordance with this set of criteria. The clinical outcome was analyzed.Methods:The study involved 1150 knees on which total knee arthroplasty was performed between 2005 and 2019 because of osteoarthritis of the knee. The mean age at operation was 73, and the mean postoperative follow-up period was 91 months. Our criteria for application of patellar replacement are given below. Criterion A pertains to evaluation of preoperative clinical symptoms related to the patellofemoral joint: (a) interview regarding presence/absence of pain around the patella, (b) cracking or pain heard or felt when standing up from a low chair, (c) pain when going upstairs/downstairs. Because it is difficult for individual patients to identify the origin of pain (patellofemoral joint or femorotibial joint), the examiner advised each patient about the location of the patellofemoral joint when checking for these symptoms. Criterion B pertains to intense narrowing or disappearance of the patellofemoral joint space on preoperative X-ray of the knee. Criterion C pertains to the intraoperatively assessed extent of patellar cartilage degeneration corresponding to class 4 of the Outerbridge classification. Patellar replacement was applied to cases satisfying at least one of these sets of criteria (A-a,-b,-c, B and C). Postoperatively, pain of the patellofemoral joint was evaluated again at the time of the last observation, using Criterion A-a,-b,-c.Results:Patellar replacement was applied to 110 knees in accordance with the criteria mentioned above. There were 82 knees satisfying at least one of the Criterion sets A-a,-b,-c, 39 knees satisfying Criterion B and 70 knees satisfying Criterion C. (Some knees satisfied 2 or 3 of Criteria A, B and C).When the pain originating from patellofemoral joint (Criterion A) was clinically assessed at the time of last observation, pain was not seen in any knee of the replacement group and the non-replacement group.Conclusion:Whether or not patellar replacement is needed should be determined on the basis of the symptoms or findings related to the patellofemoral joint, and we see no necessity of patellar replacement in cases free of such symptoms/findings. When surgery was performed in accordance with the criteria on patellar replacement as devised by us, the clinical outcome of the operated patellofemoral joint was favorable, although the follow-up period was not long. Although further follow-up is needed, the results obtained indicate that selective patellar replacement yields favorable outcome if applied to cases judged indicated with appropriate criteria.References:[1]The Effect of Surgeon Preference for Selective Patellar Resurfacing on Revision Risk in Total Knee Replacement: An Instrumental Variable Analysis of 136,116 Procedures from the Australian Orthopaedic Association National Joint Replacement Registry.Vertullo CJ, Graves SE, Cuthbert AR, Lewis PL J Bone Joint Surg Am. 2019 Jul 17;101(14):1261-1270[2]Resurfaced versus Non-Resurfaced Patella in Total Knee Arthroplasty.Allen W1, Eichinger J, Friedman R. Indian J Orthop. 2018 Jul-Aug;52(4):393-398.[3]Is Selectively Not Resurfacing the Patella an Acceptable Practice in Primary Total Knee Arthroplasty?Maradit-Kremers H, Haque OJ, Kremers WK, Berry DJ, Lewallen DG, Trousdale RT, Sierra RJ. J Arthroplasty. 2017 Apr;32(4):1143-1147.Disclosure of Interests:None declared


Author(s):  
Jeffrey E. Bischoff ◽  
Justin S. Hertzler

Computational modeling of the reconstructed knee is an important tool in designing components for maximum functionality and life. Utilization of boundary conditions consistent with in vivo gait loading in such models enables predictions of knee kinematics and polyethylene damage [1–4], which can then be used to optimize component design. Several recent clinical studies have focused on complications associated with the patellofemoral joint [5–6], highlighting the need to better understand the mechanics of this compartment of total knee arthroplasty (TKA). This study utilizes a computational model to characterize the impact of gait loading on the mechanics of the patella in TKA.


The Knee ◽  
2018 ◽  
Vol 25 (6) ◽  
pp. 1262-1271 ◽  
Author(s):  
Monther A. Gharaibeh ◽  
Elizabeth Monk ◽  
Darren B. Chen ◽  
Samuel J. MacDessi

The Knee ◽  
2017 ◽  
Vol 24 (4) ◽  
pp. 751-760 ◽  
Author(s):  
Geert Peersman ◽  
Josh Slane ◽  
Margo Dirckx ◽  
Arne Vandevyver ◽  
Philipp Dworschak ◽  
...  

Author(s):  
John M. Tarazi ◽  
Zhongming Chen ◽  
Giles R. Scuderi ◽  
Michael A. Mont

AbstractWith an expected increase in total knee arthroplasty (TKA) procedures, revision TKA (rTKA) procedures continue to be a burden on the United States health care system. The evolution of surgical techniques and prosthetic designs has, however, provided a paradigm shift in the etiology of failure mechanisms of TKA. This review can shed light on the current reasons for revision, which may lead to insights on how to improve outcomes and lower future revision risks. We will primarily focus on the epidemiology of rTKA in the present time, but we will also review this in the context of various time periods to see how the field has evolved. We will review rTKAs: 1) prior to 1997; 2) between 1997 and 2000; 3) between 2000 and 2012; and 3) in the modern era since 2012. We will further subdivide each of the sections into reasons for early (first 2 years after index procedure) versus late revisions (greater than 2 years after index procedure). In doing so, it was determined that prior to 1997, the most prevalent causes of failure were infection, patella failure, polyethylene wear, and aseptic loosening. After a major shift of failure mechanisms was described by Sharkey et al, polyethylene wear and aseptic loosening became the leading causes for revision. However, with the improved manufacturing technology and implant design, polyethylene wear was replaced with aseptic loosening and infection as the leading causes of failure between 2000 and 2012. Since that time, in the modern era of TKA, mechanical loosening and infection have taken over the most prevalent causes for failure. Hopefully, with continued developments in component design and surgical techniques, as well as increased focus on infection reduction methods, the amount of rTKA procedures will decline.


Sign in / Sign up

Export Citation Format

Share Document