Dose effects of cross-linking polyethylene for total knee arthroplasty on wear performance and mechanical properties

2007 ◽  
Vol 83B (2) ◽  
pp. 615-622 ◽  
Author(s):  
Taiyo Asano ◽  
Masao Akagi ◽  
Ian C. Clarke ◽  
Shingo Masuda ◽  
Tsunehiro Ishii ◽  
...  
2019 ◽  
Vol 8 (11) ◽  
pp. 2023 ◽  
Author(s):  
Yong-Gon Koh ◽  
Kyung-Hwan Jung ◽  
Hyoung-Taek Hong ◽  
Kang-Min Kim ◽  
Kyoung-Tak Kang

Life expectancy is on the rise and, concurrently, the demand for total knee arthroplasty (TKA), which lasts a lifetime, is increasing. To meet this demand, improved TKA designs have been introduced. Recent advances in radiography and manufacturing techniques have enabled the production of patient-specific TKA. Nevertheless, concerns regarding the wear performance, which limit the lifespan of TKA, remain to be addressed. This study aims at reducing the wear in patient-specific TKA using design optimization and parametric three-dimensional (3D) finite-element (FE) modelling. The femoral component design was implemented in a patient-specific manner, whereas the tibial insert conformity remained to be determined by design variables. The gait cycle loading condition was applied, and the optimized model was validated by the results obtained from the experimental wear tests. The wear predictions were iterated for five million gait cycles using the computational model with force-controlled input. Similar patterns for internal/external rotation and anterior/posterior translation were observed in both initial and optimal models. The wear rates for initial and optimal models were recorded as 23.2 mm3/million cycles and 16.7 mm3/million cycles, respectively. Moreover, the experimental wear rate in the optimal design was 17.8 mm3/million cycles, which validated our optimization procedure. This study suggests that tibial insert conformity is an important factor in influencing the wear performance of patient-specific TKA, and it is capable of providing improved clinical results through enhanced design selections. This finding can boost the future development of patient-specific TKA, and it can be extended to other joint-replacement designs. However, further research is required to explore the potential clinical benefits of the improved wear performance demonstrated in this study.


2021 ◽  
Vol 103-B (11) ◽  
pp. 1695-1701
Author(s):  
John H. Currier ◽  
Barbara H. Currier ◽  
Matthew P. Abdel ◽  
Daniel J. Berry ◽  
Alexander J. Titus ◽  
...  

Aims Wear of the polyethylene (PE) tibial insert of total knee arthroplasty (TKA) increases the risk of revision surgery with a significant cost burden on the healthcare system. This study quantifies wear performance of tibial inserts in a large and diverse series of retrieved TKAs to evaluate the effect of factors related to the patient, knee design, and bearing material on tibial insert wear performance. Methods An institutional review board-approved retrieval archive was surveyed for modular PE tibial inserts over a range of in vivo duration (mean 58 months (0 to 290)). Five knee designs, totalling 1,585 devices, were studied. Insert wear was estimated from measured thickness change using a previously published method. Linear regression statistical analyses were used to test association of 12 patient and implant design variables with calculated wear rate. Results Five patient-specific variables and seven implant-specific variables were evaluated for significant association with lower insert wear rate. Six were significant when controlling for other factors: greater patient age, female sex, shorter duration in vivo, polished tray, highly cross-linked PE (HXLPE), and constrained knee design. Conclusion This study confirmed that knee wear rate increased with duration in vivo. Older patients and females had significantly lower wear rates. Polished modular tibial tray surfaces, HXLPE, and constrained TKA designs were device design factors associated with significantly reduced wear rate. Cite this article: Bone Joint J 2021;103-B(11):1695–1701.


2015 ◽  
Vol 2015 ◽  
pp. 1-10 ◽  
Author(s):  
Rongying Huang ◽  
Yanqiang Liu ◽  
Jun Zhu

Knee injury is a common medical issue. A full understanding of the kinematics and mechanical properties of knees following total knee arthroplasty (TKA) repair utilizing patellar replacement (only the base of the patella is replaced) versus patellar retaining surgical techniques is still lacking. In the current paper, we investigated magnetic resonance (MR) imaging data from knees repaired by these two methods and evaluated total knee models created using imaging reconstruction technology that simulated gait conditions. Results revealed that patellar replacement had little influence on tibiofemoral kinematics, although the tibia-surface equivalent stress increased slightly. By contrast, patellar replacement had a significant influence on the patellofemoral joint; patellar internal rotation, external rotation, and medial-lateral translation were all increased. Moreover, the stress distribution on patellar prostheses was altered, resulting in an increased surface maximal equivalent stress on the corresponding area. Moreover, during the gait cycle, we found that the area with maximal equivalent stress shifted its position. Finally, the patellofemoral joint showed decreased motion stability. From the view of kinematics and mechanics, this paper suggests that patella should be retained during TKA if it is possible. The present study presented approaches and technologies for evaluating kinematics and mechanical properties of total knee joint after TKA under gait loads.


Author(s):  
Robert Brochin ◽  
Jashvant Poeran ◽  
Khushdeep S. Vig ◽  
Aakash Keswani ◽  
Nicole Zubizarreta ◽  
...  

AbstractGiven increasing demand for primary knee arthroplasties, revision surgery is also expected to increase, with periprosthetic joint infection (PJI) a main driver of costs. Recent data on national trends is lacking. We aimed to assess trends in PJI in total knee arthroplasty revisions and hospitalization costs. From the National Inpatient Sample (2003–2016), we extracted data on total knee arthroplasty revisions (n = 782,449). We assessed trends in PJI prevalence and (inflation-adjusted) hospitalization costs (total as well as per-day costs) for all revisions and stratified by hospital teaching status (rural/urban by teaching status), hospital bed size (≤299, 300–499, and ≥500 beds), and hospital region (Northeast, Midwest, South, and West). The Cochran–Armitage trend test (PJI prevalence) and linear regression determined significance of trends. PJI prevalence overall was 25.5% (n = 199,818) with a minor increasing trend: 25.3% (n = 7,828) in 2003 to 28.9% (n = 19,275) in 2016; p < 0.0001. Median total hospitalization costs for PJI decreased slightly ($23,247 in 2003–$20,273 in 2016; p < 0.0001) while median per-day costs slightly increased ($3,452 in 2003–$3,727 in 2016; p < 0.0001), likely as a function of decreasing length of stay. With small differences between hospitals, the lowest and highest PJI prevalences were seen in small (≤299 beds; 22.9%) and urban teaching hospitals (27.3%), respectively. In stratification analyses, an increasing trend in PJI prevalence was particularly seen in larger (≥500 beds) hospitals (24.4% in 2003–30.7% in 2016; p < 0.0001), while a decreasing trend was seen in small-sized hospitals. Overall, PJI in knee arthroplasty revisions appears to be slightly increasing. Moreover, increasing trends in large hospitals and decreasing trends in small-sized hospitals suggest a shift in patients from small to large volume hospitals. Decreasing trends in total costs, alongside increasing trends in per-day costs, suggest a strong impact of length of stay trends and a more efficient approach to PJI over the years (in terms of shorter length of stay).


Author(s):  
Jung-Won Lim ◽  
Yong-Beom Park ◽  
Dong-Hoon Lee ◽  
Han-Jun Lee

AbstractThis study aimed to evaluate whether manipulation under anesthesia (MUA) affect clinical outcome including range of motion (ROM) and patient satisfaction after total knee arthroplasty (TKA). It is hypothesized that MUA improves clinical outcomes and patient satisfaction after primary TKA. This retrospective study analyzed 97 patients who underwent staged bilateral primary TKA. MUA of knee flexion more than 120 degrees was performed a week after index surgery just before operation of the opposite site. The first knees with MUA were classified as the MUA group and the second knees without MUA as the control group. ROM, Knee Society Knee Score, Knee Society Functional Score, Western Ontario and McMaster Universities (WOMAC) score, and patient satisfaction were assessed. Postoperative flexion was significantly greater in the MUA group during 6 months follow-up (6 weeks: 111.6 vs. 99.8 degrees, p < 0.001; 3 months: 115.9 vs. 110.2 degrees, p = 0.001; 6 months: 120.2 vs. 117.0 degrees, p = 0.019). Clinical outcomes also showed similar results with knee flexion during 2 years follow-up. Patient satisfaction was significantly high in the MUA group during 12 months (3 months: 80.2 vs. 71.5, p < 0.001; 6 months: 85.8 vs. 79.8, p < 0.001; 12 months: 86.1 vs. 83.9, p < 0.001; 24 months: 86.6 vs. 85.5, p = 0.013). MUA yielded improvement of clinical outcomes including ROM, and patient satisfaction, especially in the early period after TKA. MUA in the first knee could be taken into account to obtain early recovery and to improve patient satisfaction in staged bilateral TKA.


2020 ◽  
Vol 04 (02) ◽  
pp. 084-089
Author(s):  
Vivek Singh ◽  
Stephen Zak ◽  
Ran Schwarzkopf ◽  
Roy Davidovitch

AbstractMeasuring patient satisfaction and surgical outcomes following total joint arthroplasty remains controversial with most tools failing to account for both surgeon and patient satisfaction in regard to outcomes. The purpose of this study was to use “The Forgotten Joint Score” questionnaire to assess clinical outcomes comparing patients who underwent a total hip arthroplasty (THA) with those who underwent a total knee arthroplasty (TKA). We conducted a retrospective review of patients who underwent primary THA or TKA between September 2016 and September 2019 and responded to the Forgotten Joint Score-12 (FJS-12) questionnaire at least at one of three time periods (3, 12, and 21 months), postoperatively. An electronic patient rehabilitation application was used to administer the questionnaire. Collected variables included demographic data (age, gender, race, body mass index [BMI], and smoking status), length of stay (LOS), and FJS-12 scores. t-test and chi-square were used to determine significance. Linear regression was used to account for demographic differences. A p-value of less than 0.05 was considered statistically significant. Of the 2,359 patients included in this study, 1,469 underwent a THA and 890 underwent a TKA. Demographic differences were observed between the two groups with the TKA group being older, with higher BMI, higher American Society of Anesthesiologists scores, and longer LOS. Accounting for the differences in demographic data, THA patients consistently had higher scores at 3 months (53.72 vs. 24.96; p < 0.001), 12 months (66.00 vs. 43.57; p < 0.001), and 21 months (73.45 vs. 47.22; p < 0.001). FJS-12 scores for patients that underwent THA were significantly higher in comparison to TKA patients at 3, 12, and 21 months postoperatively. Increasing patient age led to a marginal increase in FJS-12 score in both cohorts. With higher FJS-12 scores, patients who underwent THA may experience a more positive evolution with their surgery postoperatively than those who had TKA.


Author(s):  
Stephen Thomas ◽  
Ankur Patel ◽  
Corey Patrick ◽  
Gary Delhougne

AbstractDespite advancements in surgical technique and component design, implant loosening, stiffness, and instability remain leading causes of total knee arthroplasty (TKA) failure. Patient-specific instruments (PSI) aid in surgical precision and in implant positioning and ultimately reduce readmissions and revisions in TKA. The objective of the study was to evaluate total hospital cost and readmission rate at 30, 60, 90, and 365 days in PSI-guided TKA patients. We retrospectively reviewed patients who underwent a primary TKA for osteoarthritis from the Premier Perspective Database between 2014 and 2017 Q2. TKA with PSI patients were identified using appropriate keywords from billing records and compared against patients without PSI. Patients were excluded if they were < 21 years of age; outpatient hospital discharges; evidence of revision TKA; bilateral TKA in same discharge or different discharges. 1:1 propensity score matching was used to control patients, hospital, and clinical characteristics. Generalized Estimating Equation model with appropriate distribution and link function were used to estimate hospital related cost while logistic regression models were used to estimate 30, 60, and 90 days and 1-year readmission rate. The study matched 3,358 TKAs with PSI with TKA without PSI patients. Mean total hospital costs were statistically significantly (p < 0.0001) lower for TKA with PSI ($14,910; 95% confidence interval [CI]: $14,735–$15,087) than TKA without PSI patients ($16,018; 95% CI: $15,826–$16,212). TKA with PSI patients were 31% (odds ratio [OR]: 0.69; 95% CI: 0.51–0.95; p-value = 0.0218) less likely to be readmitted at 30 days; 35% (OR: 0.65; 95% CI: 0.50–0.86; p-value = 0.0022) less likely to be readmitted at 60 days; 32% (OR: 0.68; 95% CI: 0.53–0.88; p-value = 0.0031) less likely to be readmitted at 90 days; 28% (OR: 0.72; 95% CI: 0.60–0.86; p-value = 0.0004) less likely to be readmitted at 365 days than TKA without PSI patients. Hospitals and health care professionals can use retrospective real-world data to make informed decisions on using PSI to reduce hospital cost and readmission rate, and improve outcomes in TKA patients.


Sign in / Sign up

Export Citation Format

Share Document