scholarly journals Effects of Attachment of Plastic Aligner in Closing of Diastema of Maxillary Dentition by Finite Element Method

2019 ◽  
Vol 2019 ◽  
pp. 1-6 ◽  
Author(s):  
Yukiko Yokoi ◽  
Atsushi Arai ◽  
Jun Kawamura ◽  
Tomoko Uozumi ◽  
Yohei Usui ◽  
...  

The aim of this study was to clarify the effect of attachment on tooth movement produced by a plastic aligner. Closing of a diastema, in which the maxillary right and left central incisors moved bodily, was simulated using a finite element method. Long-term orthodontic movements of the maxillary dentition were simulated by accumulating the initial displacement of teeth produced by elastic deformation of the periodontal ligament. The incisor tipped and rotated just after placement of the aligner irrespective of the attachment. After a sufficiently long time, the incisor was upright and moved bodily in the aligner with attachment, but the incisor remained tipped in the aligner without attachment. It was demonstrated that the attachment was effective for achieving bodily movement.

Materials ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 2934
Author(s):  
Naohiko Tamaya ◽  
Jun Kawamura ◽  
Yoshinobu Yanagi

The aim of this study was to evaluate the tooth movement efficacy of retraction springs made of a new β-titanium alloy, “gum metal”, which has a low Young’s modulus and nonlinear super elasticity. Using double loop springs incorporated into an archwire made of gum metal (GUM) and titanium molybdenum alloy (TMA), the maxillary anterior teeth were moved distally to close an extraction space. The long-term movements were simulated by the finite element method. Its procedure was constructed of two steps, with the first step being the calculation of the initial tooth movement produced by elastic deformation of the periodontal ligament, and in the second step, the alveolar socket was moved by the initial tooth movement. By repeating these steps, the tooth moved by accumulating the initial tooth movement. The number of repeating calculations was equivalent to an elapsed time. In the GUM and TMA springs, the anterior teeth firstly tipped lingually, and then became upright. As a result of these movements, the canine could move bodily. The amount of space closure in GUM spring was 1.5 times that in TMA spring. The initial tipping angle of the canine in the GUM spring was larger than that in the TMA spring. The number of repeating calculations required for the bodily movement in the GUM spring was about two times that in the TMA spring. It was predicted that the speed of space closure in the GUM spring was smaller than that in the TMA spring.


2015 ◽  
Vol 16 (9) ◽  
pp. 740-743 ◽  
Author(s):  
HP Raghuveer ◽  
M Hemanth ◽  
MS Rani ◽  
Chathura Hegde ◽  
B Vedavathi ◽  
...  

ABSTRACT Background Orthodontic tooth movement occurs due to various biomechanical changes in the periodontium. Forces within the optimal range yield maximum tooth movement with minimum deleterious effects. Among various types of tooth movements, extrusion and rotational movements are seen to be associated with the least amount of root resorption and have not been studied in detail. Therefore in this study, the stress patterns in the periodontal ligament (PDL) were evaluated with extrusion and rotational movements using the finite element method FEM. Materials and methods A three-dimensional (3D) FEM model of the maxillary incisors was generated using SOLIDWORKS modeling software. Stresses in the PDL were evaluated with extrusive and rotational movements by a 3D FEM using ANSYS software with linear material properties. Results It was observed that with the application of extrusive load, the tensile stresses were seen at the apex, whereas the compressive stress was distributed at the cervical margin. With the application of rotational movements, maximum compressive stress was distributed at the apex and cervical third, whereas the tensile stress was distributed on cervical third of the PDL on the lingual surface. Conclusion For extrusive movements, stress values over the periodontal ligament was within the range of optimal stress value as proposed by Lee, with a given force system by Profitt as optimum forces for orthodontic tooth movement using linear properties. During rotation there are stresses concentrated at the apex, hence due to the concentration of the compressive forces at the apex a clinician must avoid placing heavy stresses during tooth movement. How to cite this article Hemanth M, Raghuveer HP, Rani MS, Hegde C, Kabbur KJ, Vedavathi B, Chaithra D. An Analysis of the Stress Induced in the Periodontal Ligament during Extrusion and Rotation Movements: A Finite Element Method Linear Study Part I. J Contemp Dent Pract 2015;16(9):740-743.


2019 ◽  
Vol 17 (02) ◽  
pp. 1845003 ◽  
Author(s):  
Yuki Onishi ◽  
Ryoya Iida ◽  
Kenji Amaya

A state-of-the-art tetrahedral smoothed finite element method, F-barES-FEM-T4, is demonstrated on viscoelastic large deformation problems. The stress relaxation of viscoelastic materials brings near incompressibility when the long-term Poisson’s ratio is close to 0.5. The conventional hybrid 4-node tetrahedral (T4) elements cannot avoid the shear locking and pressure checkerboarding issues, meanwhile F-barES-FEM-T4 can suppress these issues successfully by adopting the edge-based smoothed finite element method (ES-FEM) with the aid of the F-bar method and the cyclic smoothing procedure. A few examples of analyses verify that F-barES-FEM-T4 is locking-free and pressure oscillation-free in viscoelastic analyses as well as in nearly incompressible hyperelastic or elastoplastic analyses.


2001 ◽  
Vol 28 (1) ◽  
pp. 29-38 ◽  
Author(s):  
M. L. Jones ◽  
J. Hickman ◽  
J. Middleton ◽  
J. Knox ◽  
C. Volp

Sign in / Sign up

Export Citation Format

Share Document