low elastic modulus
Recently Published Documents


TOTAL DOCUMENTS

199
(FIVE YEARS 52)

H-INDEX

21
(FIVE YEARS 6)

Cancers ◽  
2022 ◽  
Vol 14 (1) ◽  
pp. 259
Author(s):  
Massimo Alfano ◽  
Irene Locatelli ◽  
Cristina D’Arrigo ◽  
Marco Mora ◽  
Giovanni Vozzi ◽  
...  

Purpose: The biochemical composition and architecture of the extracellular matrix (ECM) is known to condition development and invasiveness of neoplasms. To clarify this point, we analyzed ECM stiffness, collagen cross-linking and anisotropy in lymph nodes (LN) of Hodgkin lymphomas (HL), follicular lymphomas (FL) and diffuse large B-cell lymphomas (DLBCL), compared with non-neoplastic LN (LDN). Methods and Results: We found increased elastic (Young’s) modulus in HL and advanced FL (grade 3A) over LDN, FL grade 1–2 and DLBCL. Digital imaging evidenced larger stromal areas in HL, where increased collagen cross-linking was found; in turn, architectural modifications were documented in FL3A by scanning electron microscopy and enhanced anisotropy by polarized light microscopy. Interestingly, HL expressed high levels of lysyl oxidase (LOX), an enzyme responsible for collagen cross-linking. Using gelatin scaffolds fabricated with a low elastic modulus, comparable to that of non-neoplastic tissues, we demonstrated that HL LN-derived mesenchymal stromal cells and HL cells increased the Young’s modulus of the extracellular microenvironment through the expression of LOX. Indeed, LOX inhibition by β-aminopropionitrile prevented the gelatin stiffness increase. Conclusions: These data indicate that different mechanical, topographical and/or architectural modifications of ECM are detectable in human lymphomas and are related to their histotype and grading.


2022 ◽  
Vol 8 ◽  
Author(s):  
M. Zhang ◽  
Y.Q. Song ◽  
H.J. Lin ◽  
Z. Li ◽  
W. Li

Ti-based metallic glasses (MGs) possess high specific strength, low elastic modulus, high elasticity, high wear and corrosion resistance, and excellent biocompatibility, which make them highly attractive as lightweight high-strength materials as well as biomaterials. However, the glass forming ability (GFA) of Ti-based MGs, particularly those bearing no toxic, noble, or heavy metals, that is, Be, Pd, or Cu alike, largely sets back their wide applications for the restricted critical glass forming size of these Ti-based MGs. In this review, the outlines in developing Ti-based MGs are delineated in order to provide an overall view on the efforts ever made to fabricate bulk size Ti-based MGs. The state of the art in the knowledge on the GFA of Ti-based MGs is briefly introduced, and possible directions for fabricating bulk size toxic and noble element free Ti-based MGs are discussed.


Materials ◽  
2021 ◽  
Vol 15 (1) ◽  
pp. 137
Author(s):  
Elena N. Sheftel ◽  
Valentin A. Tedzhetov ◽  
Eugene V. Harin ◽  
Philipp V. Kiryukhantsev-Korneev ◽  
Galina S. Usmanova ◽  
...  

The paper presents results of investigation of Fe65.3–100Zr34.7–0N7.5–0 films prepared by dc magnetron deposition on glass substrates and subsequent 1-hour annealing at temperatures of 300–600 °C. The influence of the chemical and phase compositions and structure of the films, which were studied by TEM, SEM, XRD, and GDOES, on their mechanical properties determined by nanoindentation and static magnetic properties measured by VSM method is analyzed. The studied films exhibit the hardness within a range of 14–21 GPa, low elastic modulus (the value can reach 156 Gpa), and an elastic recovery of 55–83%. It was shown that the films are strong ferromagnets with the high saturation induction Bs (up to 2.1 T) and low coercive field Hc (as low as 40 A/m). The correlations between the magnetic and mechanical properties, on one hand, and the chemical composition of the films, their phase, and structural states as well, on the other hand, are discussed.


Materials ◽  
2021 ◽  
Vol 15 (1) ◽  
pp. 40
Author(s):  
Ewa Jonda ◽  
Leszek Łatka ◽  
Anna Tomiczek ◽  
Marcin Godzierz ◽  
Wojciech Pakieła ◽  
...  

In this paper, three commercial cermet powders, WC-Co-Cr, WC-Co and WC-Cr3C2-Ni, were sprayed by the High Velocity Oxy Fuel (HVOF) method onto magnesium alloy AZ31 substrate. The coatings were investigated in terms of their microstructure, phase analysis and residual stress. The manufactured coatings were analyzed extensively using optical microscopy (OM), X-ray diffraction (XRD), scanning (SEM) and transmission electron microscopy (TEM). Based on microstructure studies, it was noted that the coatings show satisfactory homogeneity. XRD analysis shows that in WC-Co, WC-Co-Cr and WC-Cr3C2-Ni coatings, main peaks are related to WC. Weaker peaks such as W2C, Co0.9W0.1, Co and W for WC-Co and W2C, Cr3C2 and Cr7C3 for WC-Cr3C2-Ni also occur. In all cermet coatings, linear stress showed compressive nature. In WC-Co and WC-Cr3C2-Ni, residual stress had a similar value, while in WC-Co-Cr, linear stress was lower. It was also proved that spraying onto magnesium substrate causes shear stress in the WC phase, most likely due to the low elastic modulus of magnesium alloy substrate.


Author(s):  
Sergey V. Gunter ◽  
Ekaterina S. Marchenko ◽  
Yuri F. Yasenchuk ◽  
Gulsharat A. Baigonakova ◽  
Alex A Volinsky

Abstract A portable universal tensile testing machine for single and cyclic loading of superelastic biomaterials is presented. It’s an alternative to large-sized stationary universal testing machines. The machine is designed to obtain uniaxial cyclic tension stress-strain curves of materials with a low elastic modulus, including biological tissues. Its portability allows using it in various conditions: classrooms, production laboratories, and in the field. An interface has been developed to connect it to a computer. Computer output of experimental data allows recording and displaying load-displacement curves, setting the number of cycles, limits, and rate of cyclic deformation. Several examples of testing various biomaterials are presented. The functional advantage of the device is the wide tensile testing speed range of 0.01-10 mm/s and cyclic loading, which allow capturing viscoelastic and superelastic behavior of biomaterials.


Coatings ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 1446
Author(s):  
Longfei Shao ◽  
Yiheng Du ◽  
Kun Dai ◽  
Hong Wu ◽  
Qingge Wang ◽  
...  

Ti and Ti alloys have charming comprehensive properties (high specific strength, strong corrosion resistance, and excellent biocompatibility) that make them the ideal choice in orthopedic and dental applications, especially in the particular fabrication of orthopedic and dental implants. However, these alloys present some shortcomings, specifically elastic modulus, wear, corrosion, and biological performance. Beta-titanium (β-Ti) alloys have been studied as low elastic modulus and low toxic or non-toxic elements. The present work summarizes the improvements of the properties systematically (elastic modulus, hardness, wear resistance, corrosion resistance, antibacterial property, and bone regeneration) for β-Ti alloys via surface modification to address these shortcomings. Additionally, the shortcomings and prospects of the present research are put forward. β-Ti alloys have potential regarding implants in biomedical fields.


Molecules ◽  
2021 ◽  
Vol 26 (23) ◽  
pp. 7131
Author(s):  
Nurul Aida Ngah ◽  
George J. Dias ◽  
Darryl C. Tong ◽  
Siti Noor Fazliah Mohd Noor ◽  
Jithendra Ratnayake ◽  
...  

Background: Platelet-rich fibrin (PRF) has gained popularity in craniofacial surgery, as it provides an excellent reservoir of autologous growth factors (GFs) that are essential for bone regeneration. However, the low elastic modulus, short-term clinical application, poor storage potential and limitations in emergency therapy use restrict its more widespread clinical application. This study fabricates lyophilised PRF (Ly-PRF), evaluates its physical and biological properties, and explores its application for craniofacial tissue engineering purposes. Material and methods: A lyophilisation method was applied, and the outcome was evaluated and compared with traditionally prepared PRF. We investigated how lyophilisation affected PRF’s physical characteristics and biological properties by determining: (1) the physical and morphological architecture of Ly-PRF using SEM, and (2) the kinetic release of PDGF-AB using ELISA. Results: Ly-PRF exhibited a dense and homogeneous interconnected 3D fibrin network. Moreover, clusters of morphologically consistent cells of platelets and leukocytes were apparent within Ly-PRF, along with evidence of PDGF-AB release in accordance with previously reports. Conclusions: The protocol established in this study for Ly-PRF preparation demonstrated versatility, and provides a biomaterial with growth factor release for potential use as a craniofacial bioscaffold.


Author(s):  
Zhen Tang ◽  
Xinghui Wei ◽  
Tian Li ◽  
Hao Wu ◽  
Xin Xiao ◽  
...  

Previous studies have found that the novel low-elastic-modulus Ti2448 alloy can significantly reduce stress shielding and contribute to better bone repair than the conventional Ti6Al4V alloy. In this study, the promotion of osteogenesis and angiogenesis by three-dimensionally printed Ti2448 were also observed in vivo. However, these were not significant in a series of in vitro tests. The stiffness of materials has been reported to greatly affect the response of macrophages, and the immunological regulation mediated by macrophages directly determines the fate of bone implants. Therefore, we designed more experiments to explore the role of three-dimensionally printed Ti2448 in macrophage activation and related osteogenesis and angiogenesis. As expected, we found a significant increase in the number of M2 macrophages around Ti2448 implants, as well as better osteogenesis and angiogenesis in vivo. In vitro studies also showed that macrophages pre-treated with Ti2448 alloy significantly promoted angiogenesis and osteogenic differentiation through increased PDGF-BB and BMP-2 secretion, and the polarization of M2 macrophages was enhanced. We deduced that Ti2448 promotes angiogenesis and osteogenesis through Piezo1/YAP signaling axis-mediated macrophage polarization and related cytokine secretion. This research might provide insight into the biological properties of Ti2448 and provide a powerful theoretical supplement for the future application of three-dimensionally printed Ti2448 implants in orthopaedic surgery.


2021 ◽  
Vol 12 (4) ◽  
pp. 5375-5383

Titanium (Ti) and its alloys have become the most promising biomaterials due to their low elastic modulus, high corrosion resistance, and relatively long-lasting ability in a physiological environment. Bioactive implants enhance the tissue interactions at the surface of the implants and promote a higher healing rate. However, titanium exhibits bio-inert nature. Hence in the present study, hydroxyapatite (HA), a well-known bioceramic, has been selected to disperse into Ti with an aim to develop bioactive Ti-based implants. Ti-HA composites with 5% and 10% HA were successfully produced by high-energy ball milling for 20 h followed by sintering (at 850 °C). Fine-grained composites were successfully produced and were found to be free from any impurities. The composites were immersed in simulated body fluid (SBF) for 4 weeks to investigate the in vitro bioactivity. From the XRD studies and scanning electron microscope observations, the presence of HA in the composite enhanced the bioactivity as reflected with higher Ca/P mineral phases on the surface of the composites compared with pure Ti substrate. From the results, it can be concluded that the bioactive nature of Ti can be enhanced by reinforcing HA to manufacture medical implants with a higher healing rate.


2021 ◽  
Vol 22 (19) ◽  
pp. 10611
Author(s):  
Yuliya Y. Khrunyk ◽  
Sabrina Ehnert ◽  
Stella V. Grib ◽  
Anatoly G. Illarionov ◽  
Stepan I. Stepanov ◽  
...  

Many current-generation biomedical implants are fabricated from the Ti-6Al-4V alloy because it has many attractive properties, such as low density and biocompatibility. However, the elastic modulus of this alloy is much larger than that of the surrounding bone, leading to bone resorption and, eventually, implant failure. In the present study, we synthesized and performed a detailed analysis of a novel low elastic modulus Ti-based alloy (Ti-28Nb-5Zr-2Ta-2Sn (TNZTS alloy)) using a variety of methods, including scanning electron microscopy, transmission electron microscopy, X-ray diffraction, and tensile test. Additionally, the in vitro biocompatibility of the TNZTS alloy was evaluated using SCP-1, SaOs-2, and THP-1 cell lines and primary human osteoblasts. Compared to Ti-6Al-4V, the elastic modulus of TNZTS alloy was significantly lower, while measures of its in vitro biocompatibility are comparable. O2 plasma treatment of the surface of the alloy significantly increased its hydrophilicity and, hence, its in vitro biocompatibility. TNZTS alloy specimens did not induce the release of cytokines by macrophages, indicating that such scaffolds would not trigger inflammatory responses. The present results suggest that the TNZTS alloy may have potential as an alternative to Ti-6Al-4V.


Sign in / Sign up

Export Citation Format

Share Document