scholarly journals Simultaneous Quantitative Determination of Polyphenolic Compounds in Blumea balsamifera (Ai-Na-Xiang, Sembung) by High-Performance Liquid Chromatography with Photodiode Array Detector

2020 ◽  
Vol 2020 ◽  
pp. 1-9 ◽  
Author(s):  
Daopeng Tan ◽  
Zhou Yang ◽  
Qianru Zhang ◽  
Hua Ling ◽  
Yimei Du ◽  
...  

A high-performance liquid chromatography method was developed for simultaneous quantification of 18 polyphenolic compounds from the leaves of Blumea balsamifera, including 17 flavonoids and 1 phenylethanone. The B. balsamifera extraction was separated by a Kromasil C18 column (250 × 4.6 mm, 5 μm) with a binary gradient mobile phase consisting of acetonitrile and 0.2% aqueous acetic acid. A photodiode array detector (PDA) was used to record the signals of investigated constituents. The linearity, sensitivity, stability, precision, and accuracy of the established assay methods were assessed to meet the requirements of quantitative determination. Samples extracted by reflux in 25 mL of 80% methanol for 30 minutes were selected for the extraction method. The 18 compounds were accurately identified by comparing with the reference compounds. The purity of each peak was confirmed by the base peak in the mass spectrum. The contents of 18 compounds in Blumea samples from four different regions were successfully determined. The results also showed that 3,3′,5,7-tetrahydroxy-4′-methoxyflavanone was the most abundant constituent, which could be used as a potential chemical marker for quality control of B. balsamifera and Chinese patent medications containing B. balsamifera herb.

Author(s):  
Kanan G Gamit ◽  
Niraj Y Vyas ◽  
Nishit D Patel ◽  
Manan A Raval

Objective: A study was aimed to estimate guggulsterone-Z (GZ) in Gokshuradi Guggulu (GG).Methods: An analytical method was developed and validated using Waters Alliance high-performance liquid chromatography system (Empower software), equipped with photodiode array detector. Separation was achieved using Phenomenex, C-18 (250 mm×4.6 mm, 5 μ) column. Mobile phase consisted of acetonitrile:water (70:30,v/v). Flow rate was set to 1 ml/min and detection was performed at 251 nm.Results and Discussion: Validation parameters such as linearity, precision, accuracy, limit of detection, limit of quantification, and robustness were performed. Amount of GZ was estimated using linearity equation.Conclusion: GG was found to contain 0.815±0.03 g% w/w GZ. Validated method may be used as one of the parameters to standardize the formulation.


Sign in / Sign up

Export Citation Format

Share Document