scholarly journals Keyframe Selection of Frame Similarity to Generate Scene Segmentation Based on Point Operation

Author(s):  
Wisnu Widiarto ◽  
Mochamad Hariadi ◽  
Eko Mulyanto Yuniarno

<span lang="EN-US">Video segmentation has been done by grouping similar frames according to the threshold. Two-frame similarity calculations have been performed based on several operations on the frame: point operation, spatial operation, geometric operation and arithmatic operation. In this research, similarity calculations have been applied using point operation: frame difference, gamma correction and peak signal to noise ratio. Three-point operation has been performed in accordance with the intensity and pixel frame values. Frame differences have been operated based on the pixel value level. Gamma correction has analyzed pixel values and lighting values. The peak signal to noise ratio (PSNR) has been related to the difference value (noise) between the original frame and the next frame. If the distance difference between the two frames was smaller then the two frames were more similar. If two frames had a higher gamma correction factor, then the correction factor would have an increasingly similar effect on the two frames. If the value of PSNR was greater then the comparison of two frames would be more similar. The combination of the three point operation methods would be able to determine several similar frames incorporated in the same segment</span>

2000 ◽  
Vol 88 (6) ◽  
pp. 2279-2286 ◽  
Author(s):  
Dean O. Kuethe ◽  
Arvind Caprihan ◽  
H. Michael Gach ◽  
Irving J. Lowe ◽  
Eiichi Fukushima

We partially obstructed the left bronchi of rats and imaged an inert insoluble gas, SF6, in the lungs with NMR using a technique that clearly differentiates obstructed and normal ventilation. When the inhaled fraction of O2is high, SF6 concentrates dramatically in regions of the lung with low ventilation-to-perfusion ratios (V˙a/Q˙); therefore, these regions are brighter in an image than whereV˙a/Q˙ values are normal or high. A second image, made when the inhaled fraction of O2 is low, serves as a reference because the SF6 fraction is nearly uniform, regardless ofV˙a/Q˙. The quotient of the first and second images displays the low-V˙a/Q˙ regions and is corrected for other causes of brightness variation. The technique may provide sufficient quantification ofV˙a/Q˙ to be a useful research tool. The noise in the quotient image is described by the probability density function for the quotient of two normal random variables. When the signal-to-noise ratio of the denominator image is >10, the signal-to-noise ratio of the quotient image is similar to that of the parent images and decreases with pixel value.


Sensors ◽  
2018 ◽  
Vol 18 (8) ◽  
pp. 2598
Author(s):  
Min Kim ◽  
Jinhyoung Park ◽  
Qifa Zhou ◽  
Koping Shung

In this article, an approach to designing and developing an ultrahigh frequency (≤600 MHz) ultrasound analog frontend with Golay coded excitation sequence for high resolution imaging applications is presented. For the purpose of visualizing specific structures or measuring functional responses of micron-sized biological samples, a higher frequency ultrasound is needed to obtain a decent spatial resolution while it lowers the signal-to-noise ratio, the difference in decibels between the signal level and the background noise level, due to the higher attenuation coefficient. In order to enhance the signal-to-noise ratio, conventional approach was to increase the transmit voltage level. However, it may cause damaging the extremely thin piezoelectric material in the ultrahigh frequency range. In this paper, we present a novel design of ultrahigh frequency (≤600 MHz) frontend system capable of performing pseudo Golay coded excitation by configuring four independently operating pulse generators in parallel and the consecutive delayed transmission from each channel. Compared with the conventional monocycle pulse approach, the signal-to-noise ratio of the proposed approach was improved by 7–9 dB without compromising the spatial resolution. The measured axial and lateral resolutions of wire targets were 16.4 µm and 10.6 µm by using 156 MHz 4 bit pseudo Golay coded excitation, respectively and 4.5 µm and 7.7 µm by using 312 MHz 4 bit pseudo Golay coded excitation, respectively.


2017 ◽  
Vol 14 (1) ◽  
pp. 149-160
Author(s):  
Lazar Cokic ◽  
Aleksandra Marjanovic ◽  
Sanja Vujnovic ◽  
Zeljko Djurovic

In this paper a short theoretical overview of differential quantizer and its implementations is given. Afterward, the effect of the order of prediction in differential quantizer and the effect of the difference in order of predictor in the input and output of differential quantizer is analyzed. Then it was proceeded with the examination of the robustness of the differential quantizer in the case in which a noise signal is brought to the input of the differential quantizer, instead of the clean speech signal. The analysis was conducted with a uniform distribution, as well as the noise with the gaussian distribution, and the obtained results were adequately commented on. Also, experimentally a limit was set which refers to the intensity of the noise and still enable results which are better that a regular uniform quantizer. The whole analysis is done by using the fixed number of bits in quantization, i.e. 12-bit quantizer is used in all the implementations of differential quantizer. In the conclusion of this paper there is a discussion about the possibility of implementing a differential quantizer which will be able to recognize which noise attacks the system, and in addition to that, in what form it adapts its coefficients so that it at any moment acquires the optimal signal to noise ratio.


Stats ◽  
2019 ◽  
Vol 2 (1) ◽  
pp. 164-173 ◽  
Author(s):  
Warisa Thangjai ◽  
Sa-Aat Niwitpong

In this article, we propose approaches for constructing confidence intervals for the single signal-to-noise ratio (SNR) of a log-normal distribution and the difference in the SNRs of two log-normal distributions. The performances of all of the approaches were compared, in terms of the coverage probability and average length, using Monte Carlo simulations for varying values of the SNRs and sample sizes. The simulation studies demonstrate that the generalized confidence interval (GCI) approach performed well, in terms of coverage probability and average length. As a result, the GCI approach is recommended for the confidence interval estimation for the SNR and the difference in SNRs of two log-normal distributions.


2020 ◽  
Vol 496 (1) ◽  
pp. 739-753 ◽  
Author(s):  
Raghunath Ghara ◽  
T Roy Choudhury

ABSTRACT A possible way to study the reionization of cosmic hydrogen is by observing the large ionized regions (bubbles) around bright individual sources, e.g. quasars, using the redshifted 21 cm signal. It has already been shown that matched filter-based methods are not only able to detect the weak 21 cm signal from these bubbles but also aid in constraining their properties. In this work, we extend the previous studies to develop a rigorous Bayesian framework to explore the possibility of constraining the parameters that characterize the bubbles. To check the accuracy with which we can recover the bubble parameters, we apply our method on mock observations appropriate for the upcoming SKA1-low. For a region of size ≳50 cMpc around a typical quasar at redshift 7, we find that ≈20 h of integration with SKA1-low will be able to constrain the size and location of the bubbles, as well as the difference in the neutral hydrogen fraction inside and outside the bubble, with $\lesssim 10$ per cent precision. The recovery of the parameters are more precise and the signal-to-noise ratio of the detected signal is higher when the bubble sizes are larger and their shapes are close to spherical. Our method can be useful in identifying regions in the observed field that contain large ionized regions and hence are interesting for following up with deeper integration times.


Author(s):  
David A. Grano ◽  
Kenneth H. Downing

The retrieval of high-resolution information from images of biological crystals depends, in part, on the use of the correct photographic emulsion. We have been investigating the information transfer properties of twelve emulsions with a view toward 1) characterizing the emulsions by a few, measurable quantities, and 2) identifying the “best” emulsion of those we have studied for use in any given experimental situation. Because our interests lie in the examination of crystalline specimens, we've chosen to evaluate an emulsion's signal-to-noise ratio (SNR) as a function of spatial frequency and use this as our critereon for determining the best emulsion.The signal-to-noise ratio in frequency space depends on several factors. First, the signal depends on the speed of the emulsion and its modulation transfer function (MTF). By procedures outlined in, MTF's have been found for all the emulsions tested and can be fit by an analytic expression 1/(1+(S/S0)2). Figure 1 shows the experimental data and fitted curve for an emulsion with a better than average MTF. A single parameter, the spatial frequency at which the transfer falls to 50% (S0), characterizes this curve.


Author(s):  
W. Kunath ◽  
K. Weiss ◽  
E. Zeitler

Bright-field images taken with axial illumination show spurious high contrast patterns which obscure details smaller than 15 ° Hollow-cone illumination (HCI), however, reduces this disturbing granulation by statistical superposition and thus improves the signal-to-noise ratio. In this presentation we report on experiments aimed at selecting the proper amount of tilt and defocus for improvement of the signal-to-noise ratio by means of direct observation of the electron images on a TV monitor.Hollow-cone illumination is implemented in our microscope (single field condenser objective, Cs = .5 mm) by an electronic system which rotates the tilted beam about the optic axis. At low rates of revolution (one turn per second or so) a circular motion of the usual granulation in the image of a carbon support film can be observed on the TV monitor. The size of the granular structures and the radius of their orbits depend on both the conical tilt and defocus.


Author(s):  
D. C. Joy ◽  
R. D. Bunn

The information available from an SEM image is limited both by the inherent signal to noise ratio that characterizes the image and as a result of the transformations that it may undergo as it is passed through the amplifying circuits of the instrument. In applications such as Critical Dimension Metrology it is necessary to be able to quantify these limitations in order to be able to assess the likely precision of any measurement made with the microscope.The information capacity of an SEM signal, defined as the minimum number of bits needed to encode the output signal, depends on the signal to noise ratio of the image - which in turn depends on the probe size and source brightness and acquisition time per pixel - and on the efficiency of the specimen in producing the signal that is being observed. A detailed analysis of the secondary electron case shows that the information capacity C (bits/pixel) of the SEM signal channel could be written as :


1979 ◽  
Vol 10 (4) ◽  
pp. 221-230 ◽  
Author(s):  
Veronica Smyth

Three hundred children from five to 12 years of age were required to discriminate simple, familiar, monosyllabic words under two conditions: 1) quiet, and 2) in the presence of background classroom noise. Of the sample, 45.3% made errors in speech discrimination in the presence of background classroom noise. The effect was most marked in children younger than seven years six months. The results are discussed considering the signal-to-noise ratio and the possible effects of unwanted classroom noise on learning processes.


2020 ◽  
Vol 63 (1) ◽  
pp. 345-356
Author(s):  
Meital Avivi-Reich ◽  
Megan Y. Roberts ◽  
Tina M. Grieco-Calub

Purpose This study tested the effects of background speech babble on novel word learning in preschool children with a multisession paradigm. Method Eight 3-year-old children were exposed to a total of 8 novel word–object pairs across 2 story books presented digitally. Each story contained 4 novel consonant–vowel–consonant nonwords. Children were exposed to both stories, one in quiet and one in the presence of 4-talker babble presented at 0-dB signal-to-noise ratio. After each story, children's learning was tested with a referent selection task and a verbal recall (naming) task. Children were exposed to and tested on the novel word–object pairs on 5 separate days within a 2-week span. Results A significant main effect of session was found for both referent selection and verbal recall. There was also a significant main effect of exposure condition on referent selection performance, with more referents correctly selected for word–object pairs that were presented in quiet compared to pairs presented in speech babble. Finally, children's verbal recall of novel words was statistically better than baseline performance (i.e., 0%) on Sessions 3–5 for words exposed in quiet, but only on Session 5 for words exposed in speech babble. Conclusions These findings suggest that background speech babble at 0-dB signal-to-noise ratio disrupts novel word learning in preschool-age children. As a result, children may need more time and more exposures of a novel word before they can recognize or verbally recall it.


Sign in / Sign up

Export Citation Format

Share Document