Voltage Flickering Reduction Using Distribution STATCOM

Author(s):  
Yahia M Esmail ◽  
S K Elsayed ◽  
M A Mehanna

<em><span>Power Quality is becoming intensity concerned from both electric utilities and customers. Voltage Flicker is a major power quality problem as it has a significant impact on both the equipment and production environment. This work describes the voltage control technique of reduction of voltage flicker and clearing fault using Distribution Static Synchronous Compensator (DSTATCOM). The test system used is IEEE 9-bus distribution system clarified the optimal location of DSTATCOM by using Artificial Neural Network. A simulation was done using MATLAB/Simulink software.</span></em>

Author(s):  
Yahia M Esmail ◽  
S K Elsayed ◽  
M A Mehanna

<p class="DefaultParagraphFont1" align="center"> </p><p align="center"><strong><em>Abstract</em></strong></p><p><em>         Electrical Power Quality is becoming intensity concerned from both electric utilities and customers. Voltage Fluctuations is a major power quality problem as it has a significant impact on both the equipment and production environment. This work describes the voltage control technique of mitigation of voltage fluctuations and clearing fault using Distribution Static Synchronous Compensator (DSTATCOM). The test system used is IEEE 9-bus distribution system clarified optimal location of DSTATCOM by using Artificial Neural Network (ANN). A simulation was done using MATLAB/Simulink software to obtain the results..</em></p><p> </p>


In this work, the Impact of integration of multiple Photo Voltaic distributed generators (PV-DGs) on power quality of the distribution system is analyzed under static and dynamic loads. Major power quality parameters considered for the analysis are voltage deviation (VD), Total Real power and reactive power line losses (PT L & QT L) and Total Harmonic Distortion of Voltage at Buses (THDv ). Test system considered for the study is the IEEE-9 bus test system and types of loads considered are Static RL and Induction motors. Modeling and simulation of test system, PVs and Induction motor loads are carriedoutinMATLAB/SIMULINK software package


Author(s):  
Miska Prasad ◽  
Ashok Kumar Akella

<p><em>This paper describes the comparative analysis of three different control techniques of distributed flexible AC transmission system (DFACTS) controller called as distributed static synchronous compensator (DSTATCOM), </em><em>aimed at power quality (PQ) enhancement in terms of voltage sag mitigation in a three-phase four-wire (3p4w) distribution system. A DSTATCOM is one of the major power quality improvement devices which consist of a DC energy source, a voltage source inverter (VSI), a filter, a coupling transformer and the control system. The control strategy based on synchronous reference frame (SRF) theory, instantaneous active and reactive current (IARC) theory and propositional-integral (PI) controller has been used for reference current generation of voltage source inverter (VSI) based DSTATCOM. The SRF, IARC and PI control based DSTATCOM is validated through dynamic simulation in a MATLAB\SIMULINK environment under linear as well as nonlinear loads.</em></p>


Author(s):  
Zuhaila Mat Yasin ◽  
Izni Nadhirah Sam’ón ◽  
Norziana Aminudin ◽  
Nur Ashida Salim ◽  
Hasmaini Mohamad

<p>Monitoring fault current is very important in power system protection. Therefore, the impact of installing Distributed Generation (DG) on the fault current is investigated in this paper. Three types of fault currents which are single line-to-ground, double line-to-ground and three phase fault are analyzed at various fault locations. The optimal location of DG was identified heuristically using power system simulation program for planning, design and analysis of distribution system (PSS/Adept). The simulation was conducted by observing the power losses of the test system by installing DG at each load buses. Bus with minimum power loss was chosen as the optimal location of DG. In order to study the impact of DG to the fault current, various locations and sizes of DG were also selected. The simulations were conducted on IEEE 33-bus distribution test system and IEEE 69-bus distribution test system. The results showed that the impact of DG to the fault current is significant especially when fault occurs at busses near to DG location.</p>


2016 ◽  
Vol 818 ◽  
pp. 52-57 ◽  
Author(s):  
Faridullah Kakar ◽  
Abdullah Asuhaimi bin Mohd Zin ◽  
Mohd Hafiz bin Habibuddin

Voltage sag and harmonics are the most frequent power quality problems faced by industrial and commercial customers today. Situation has been aggravated by modern sensitive industrial equipments which introduce system harmonics due to their inherent V-I characteristics. In this paper, proportional integral (PI) control technique based dynamic voltage restorer (DVR) is implemented in power distribution system to suppress voltage sag and harmonics under linear, non-linear and induction motor load conditions. Real-time power distribution system and DVR test models are built in Matlab/Simulink software. Simulation results exhibit excellent PI control approach with effective performance yielding excellent voltage regulation.


The Indian economy has been growing at a fast pace since the beginning of this millennium. Due to constraints in the availability of fuel and environmental concerns, the power generation sector has not kept pace with other industrial sectors. One way of increasing the power availability is by reducing the high losses in the existing power transmission and distribution systems. The current increases in the motor windings when the voltages in the three phases are unbalanced. Compensation for reactive power and unbalance in the power distribution system are key factors in improving the power quality to the end user. A Distributed Static Compensator [DSTATCOM] is a custom power device, which is connected in shunt with the load in the distribution system to compensate the reactive power due unbalanced loads. The performance of the DSTATCOM is based on the control technique used for finding the voltage referred and current components to be considered. Voltage compensation is defined as the error in voltage in the grid and that the value of voltage that has to be induced in the grid. This is analyzed by using DSTATCOM for voltage compensation with series converter controller block. This paper gives the simulation of voltage compensation to rectify the issue of voltage swell/sag in order to improve the power quality in the distribution system.


Author(s):  
Muhira Dzar Faraby ◽  
Ontoseno Penangsang ◽  
Rony Seto Wibowo ◽  
Andi Fitriati

<span lang="EN-US">Power quality has an important role in the distribution of electrical energy. The use of non-linear load can generate harmonic spread which can reduce the power quality in the radial distribution system. This research is in form of coordinated planning by combining distributed generation placement, capacitor placement and network reconfiguration to simultaneously minimize active power losses, total harmonic distortion (THD), and voltage deviation as an objective function using the particle swarm optimization method. This optimization technique will be tested on two types of networks in the form 33-bus and 69-bus IEEE Standard Test System to show effectiveness of the proposed method. The use of MATLAB programming shows the result of simulation of increasing power quality achieved for all scenario of proposed method.</span>


Author(s):  
Fredrick Nkado ◽  
Franklin Nkado

Recently, the demand for electrical energy has increased more than energy production due to the growing population and industrialization. Therefore, the distributed generators integration (DGs) into the distribution system has been widely adopted. This work examines the effect of photovoltaic-based distributed generator (PV-DG) integration on power quality effect of a radial distribution system. Firstly, the capacity and optimum placement of the PV-DG units in the distribution network are determined by employing the particle swarm optimization (PSO) algorithm. Then, the impact of PV-DG integration on voltage harmonic distortion is analyzed by performing harmonic load flow analysis. Also, the P-V curve method is used to evaluate the effects of higher PV-DG penetration levels on loading margin and voltage magnitude. The simulation results show that as the PV-DG units’ penetration level increases, a greater level of harmonic distortion is injected, implying that the PV-DG units should only be integrated up to the network’s maximum capacity. Therefore, high harmonic distortion is produced when the PV-DG units are penetrated beyond this maximum penetration level, which has a negative impact on the system’s performance. The total voltage harmonic distortion is 4.17 % and 4.24 % at PCC1 and PCC2 at the highest penetration level, allowing the acceptable harmonic distortion limit. Also, grid-connected PV-DG units improve loading margin and voltage magnitude, according to the P-V curve results. The standard IEEE-33 bus distribution system is modelled in ETAP software and is used as a test system for this study.