A Step Forward in the Quality Control Testing of Inactivated Rabies Vaccines — Extensive Evaluation of European Vaccines by Using Alternative Methods to the In Vivo Potency Tests

2015 ◽  
Vol 43 (1) ◽  
pp. 19-27 ◽  
Author(s):  
Alexandre Servat ◽  
Sébastien Kempff ◽  
Valère Brogat ◽  
Estelle Litaize ◽  
Jean-Luc Schereffer ◽  
...  
1995 ◽  
Vol 23 (1) ◽  
pp. 61-73
Author(s):  
Coenraad Hendriksen ◽  
Johan van der Gun

In the quality control of vaccine batches, the potency testing of inactivated vaccines is one of the areas requiring very large numbers of animals, which usually suffer significant distress as a result of the experimental procedures employed. This article deals with the potency testing of diphtheria and tetanus toxoids, two vaccines which are used extensively throughout the world. The relevance of the potency test prescribed by the European Pharmacopoeia monographs is questioned. The validity of the potency test as a model for the human response, the ability of the test to be standardised, and the relevance of the test in relation to the quality of the product are discussed. It is concluded that the potency test has only limited predictive value for the antitoxin responses to be expected in recipients of these toxoids. An alternative approach for estimating the potency of toxoid batches is discussed, in which a distinction is made between estimation of the immunogenic potency of the first few batches obtained from a seed lot and monitoring the consistency of the quality of subsequent batches. The use of animals is limited to the first few batches. Monitoring the consistency of the quality of subsequent batches is based on in vitro test methods. Factors which hamper the introduction and acceptance of the alternative approach are considered. Finally, proposals are made for replacement, reduction and/or refinement (the Three Rs) in the use of animals in the routine potency testing of toxoids.


1998 ◽  
Vol 26 (5) ◽  
pp. 679-708 ◽  
Author(s):  
Horst Spielmann ◽  
Michael Balls ◽  
Jack Dupuis ◽  
Wolfgang J. W. Pape ◽  
Odile de Silva ◽  
...  

In 1996, the Scientific Committee on Cosmetology of DGXXIV of the European Commission asked the European Centre for the Validation of Alternative Methods to test eight UV filter chemicals from the 1995 edition of Annex VII of Directive 76/768/EEC in a blind trial in the in vitro 3T3 cell neutral red uptake phototoxicity (3T3 NRU PT) test, which had been scientifically validated between 1992 and 1996. Since all the UV filter chemicals on the positive list of EU Directive 76/768/EEC have been shown not to be phototoxic in vivo in humans under use conditions, only negative effects would be expected in the 3T3 NRU PT test. To balance the number of positive and negative chemicals, ten phototoxic and ten non-phototoxic chemicals were tested under blind conditions in four laboratories. Moreover, to assess the optimum concentration range for testing, information was provided on appropriate solvents and on the solubility of the coded chemicals. In this study, the phototoxic potential of test chemicals was evaluated in a prediction model in which either the Photoirritation Factor (PIF) or the Mean Photo Effect (MPE) were determined. The results obtained with both PIF and MPE were highly reproducible in the four laboratories, and the correlation between in vitro and in vivo data was almost perfect. All the phototoxic test chemicals provided a positive result at concentrations of 1μg/ml, while nine of the ten non-phototoxic chemicals gave clear negative results, even at the highest test concentrations. One of the UV filter chemicals gave positive results in three of the four laboratories only at concentrations greater than 100μg/ml; the other laboratory correctly identified all 20 of the test chemicals. An analysis of the impact that exposure concentrations had on the performance of the test revealed that the optimum concentration range in the 3T3 NRU PT test for determining the phototoxic potential of chemicals is between 0.1μg/ml and 10μg/ml, and that false positive results can be obtained at concentrations greater than 100μg/ml. Therefore, the positive results obtained with some of the UV filter chemicals only at concentrations greater than 100μg/ml do not indicate a phototoxic potential in vivo. When this information was taken into account during calculation of the overall predictivity of the 3T3 NRU PT test in the present study, an almost perfect correlation of in vitro versus in vivo results was obtained (between 95% and 100%), when either PIF or MPE were used to predict the phototoxic potential. The management team and participants therefore conclude that the 3T3 NRU PT test is a valid test for correctly assessing the phototoxic potential of UV filter chemicals, if the defined concentration limits are taken into account.


2021 ◽  
Author(s):  
Carmen Seller Oria ◽  
Adrian Thummerer ◽  
Jeffrey Free ◽  
Johannes A. Langendijk ◽  
Stefan Both ◽  
...  

2017 ◽  
Vol 217 (2) ◽  
pp. 635-647 ◽  
Author(s):  
Zhenwei Gong ◽  
Inmaculada Tasset ◽  
Antonio Diaz ◽  
Jaime Anguiano ◽  
Emir Tas ◽  
...  

Chaperone-mediated autophagy (CMA) serves as quality control during stress conditions through selective degradation of cytosolic proteins in lysosomes. Humanin (HN) is a mitochondria-associated peptide that offers cytoprotective, cardioprotective, and neuroprotective effects in vivo and in vitro. In this study, we demonstrate that HN directly activates CMA by increasing substrate binding and translocation into lysosomes. The potent HN analogue HNG protects from stressor-induced cell death in fibroblasts, cardiomyoblasts, neuronal cells, and primary cardiomyocytes. The protective effects are lost in CMA-deficient cells, suggesting that they are mediated through the activation of CMA. We identified that a fraction of endogenous HN is present at the cytosolic side of the lysosomal membrane, where it interacts with heat shock protein 90 (HSP90) and stabilizes binding of this chaperone to CMA substrates as they bind to the membrane. Inhibition of HSP90 blocks the effect of HNG on substrate translocation and abolishes the cytoprotective effects. Our study provides a novel mechanism by which HN exerts its cardioprotective and neuroprotective effects.


2021 ◽  
Author(s):  
The Michael J Fox Foundation Pff Standardization Consortium

This is a consensus protocol developed through discussions with Laura Volpicelli-Daley, Caryl Sortwell, Kelvin Luk, Lindsey Gottler, and Virginia Lee. This protocol is intended for research purposes only, using specially-formulated monomeric alpha-synuclein protein available for purchase at Proteos, Inc as the result of efforts by The Michael J. Fox Foundation (MJFF). Each batch of the “Alpha-Synuclein Monomer Protein for Making Pre- Formed Fibrils” has undergone internal purification and quality control at Proteos in addition to external validation to confirm successful generation of pathogenic aSyn PFFs. See Reference section for methods and results from application of alpha-synuclein pre-formed fibrils (aSyn PFFs) in primary neuron cultures in vitro or in mice in vivo. This protocol is referenced in the Polinski et al 2018 paper entitled "Best Practices for Generating and Using Alpha-Synuclein Pre-Formed Fibrils to Model Parkinson's Disease in Rodents" (doi: 10.3233/JPD-171248).


2021 ◽  
Author(s):  
The Michael J Fox Foundation Pff Standardization Consortium

This is a consensus protocol developed through discussions with Laura Volpicelli-Daley, Caryl Sortwell, Kelvin Luk, Lindsey Gottler, and Virginia Lee. This protocol is intended for research purposes only, using specially-formulated monomeric alpha-synuclein protein available for purchase at Proteos, Inc as the result of efforts by The Michael J. Fox Foundation (MJFF). Each batch of the “Alpha-Synuclein Monomer Protein for Making Pre- Formed Fibrils” has undergone internal purification and quality control at Proteos in addition to external validation to confirm successful generation of pathogenic aSyn PFFs. See Reference section for methods and results from application of alpha-synuclein pre-formed fibrils (aSyn PFFs) in primary neuron cultures in vitro or in mice in vivo. This protocol is referenced in the Polinski et al 2018 paper entitled "Best Practices for Generating and Using Alpha-Synuclein Pre-Formed Fibrils to Model Parkinson's Disease in Rodents" (doi: 10.3233/JPD-171248).


2014 ◽  
Vol 48 (2) ◽  
pp. 210-218 ◽  
Author(s):  
Magdalena Fundowicz ◽  
Miguel Macia ◽  
Susanna Marin ◽  
Marta Bogusz-Czerniewicz ◽  
Ewelina Konstanty ◽  
...  

Abstract Background. We performed a clinical audit of preoperative rectal cancer treatment at two European radiotherapy centres (Poland and Spain). The aim was to independently verify adherence to a selection of indicators of treatment quality and to identify any notable inter-institutional differences. Methods. A total of 162 patients, in Catalan Institute of Oncology (ICO) 68 and in Greater Poland Cancer Centre (GPCC) 94, diagnosed with locally advanced rectal cancer and treated with preoperative radiotherapy or radiochemotherapy were included in retrospective study. A total of 7 quality control measures were evaluated: waiting time, multidisciplinary treatment approach, portal verification, in vivo dosimetry, informed consent, guidelines for diagnostics and therapy, and patient monitoring during treatment. Results. Several differences were observed. Waiting time from pathomorphological diagnosis to initial consultation was 31 (ICO) vs. 8 (GPCC) days. Waiting time from the first visit to the beginning of the treatment was twice as long at the ICO. At the ICO, 82% of patient experienced treatment interruptions. The protocol for portal verification was the same at both institutions. In vivo dosimetry is not used for this treatment localization at the ICO. The ICO utilizes locally-developed guidelines for diagnostics and therapy, while the GPCC is currently developing its own guidelines. Conclusions. An independent external clinical audit is an excellent approach to identifying and resolving deficiencies in quality control procedures. We identified several procedures amenable to improvement. Both institutions have since implemented changes to improve quality standards. We believe that all radiotherapy centres should perform a comprehensive clinical audit to identify and rectify deficiencies.


Author(s):  
A. Sawangsuriya ◽  
P. Jitareekul ◽  
Y. Taesiri ◽  
S. Sirisak ◽  
W. Lawanwisut

2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Sophia Mziray ◽  
Betty A. Maganda ◽  
Kissa Mwamwitwa ◽  
Adam M. Fimbo ◽  
Seth Kisenge ◽  
...  

Abstract Background Antiretroviral drugs (ARVs) have significantly reduced morbidity, mortality and improved the quality of life of people living with HIV infection. Poor quality ARVs may result in harmful consequences such as adverse drug reactions, treatment failure and development of drug resistant strains and sometimes death, which in turn may undermine the healthcare delivery system. To ensure optimal treatment outcomes, medicines quality control must be undertaken regularly. This study was aimed at evaluating the quality of ARVs circulating on the Tanzania Mainland market. Methods This was a survey study. ARVs samples were collected in 20 regions of Tanzania Mainland, between 2012 and 2018. All sampled ARVs were subjected to screening testing using the Global Pharma Health Fund® Mini-Lab kits. Sampled ARV’s that failed screening test or yielded doubtful results and 10 % (10 %) of all that complied with the screening test requirements were selected for full quality control testing. Quality control testing was conducted at the Tanzania Medicines and Medical Devices Authority (TMDA) laboratory a World Health Organisation prequalified. Samples collected from the medicine distribution outlets were also, subjected to product information review. Results A total of 2,630 samples were collected, of which 83.7 % (2200/2630) were from port of entry (POEs). All sampled ARVs were screened and conformed to the specifications, except of the fixed dose combination (FDC) lopinavir/ritonavir 0.27 % (7/2630) and lamivudine/zidovudine/nevirapine 0.27 % (7/2630) that failed the disintegration test. Out of the 100 samples selected for full quality control testing, 3 % of them failed to comply with the specifications, of which FDC stavudine/lamivudine/nevirapine failed disintegration and assay tests 2 % (2/100) and 1 % (1/100), respectively. Samples failing the assay test had low content of stavudine (86.6 %) versus specification limits (90 -110 %). Out of the 430 samples which were subjected to product information review, 25.6 % (110/430) failed to comply with the TMDA packaging and labelling requirements. Conclusions The quality of majority of ARVs circulating on the Tanzania Mainland market was good, even so, significant deficiencies on labelling and packaging were observed. These results call for continuous monitoring of quality of medicines circulating on the Tanzania Mainland market.


Sign in / Sign up

Export Citation Format

Share Document