Anchor Design and Bone Mineral Density Affect the Pull-Out Strength of Suture Anchors in Rotator Cuff Repair

2004 ◽  
Vol 32 (6) ◽  
pp. 1466-1473 ◽  
Author(s):  
Markus J. Tingart ◽  
Maria Apreleva ◽  
Janne Lehtinen ◽  
David Zurakowski ◽  
Jon J. P. Warner
2017 ◽  
Vol 46 (1) ◽  
pp. 98-108 ◽  
Author(s):  
Tanujan Thangarajah ◽  
Anita Sanghani-Kerai ◽  
Frederick Henshaw ◽  
Simon M. Lambert ◽  
Catherine J. Pendegrass ◽  
...  

Background: The success of rotator cuff repair is primarily dependent on tendon-bone healing. Failure is common because weak scar tissue replaces the native enthesis, rendering it prone to reruptures. A demineralized bone matrix (DBM) consists of a network of collagen fibers that provide a sustained release of growth factors such as bone morphogenetic proteins. Previous studies have demonstrated that it can regenerate a fibrocartilaginous enthesis. Hypothesis: The use of a DBM and mesenchymal stem cells (MSCs) at the healing enthesis will result in a higher bone mineral density at the tendon insertion and will enhance the regeneration of a morphologically superior enthesis when compared with an acellular human dermal matrix. Study Design: Controlled laboratory study. Methods: Eighteen female Wistar rats underwent unilateral detachment of the supraspinatus tendon. Three weeks later, tendon repair was carried out in animals randomized into 3 groups: group 1 received augmentation of the repair with a cortical allogenic DBM (n = 6); group 2 received augmentation with a nonmeshed, ultrathick, acellular human dermal matrix (n = 6); and group 3 underwent tendon-bone repair without a scaffold (n = 6). All animals received 1 × 106 MSCs delivered in fibrin glue to the repair site. Specimens were retrieved at 6 weeks postoperatively for histological analysis and the evaluation of bone mineral density. Results: All groups demonstrated closure of the tendon-bone gap with a fibrocartilaginous enthesis. Although there were no significant differences in the enthesis maturation and modified Movin scores, repair augmented with a dermal matrix + MSCs exhibited a disorganized enthesis, abnormal collagen fiber arrangement, and greater cellularity compared with other MSC groups. Only repairs augmented with a DBM + MSCs reached a bone mineral density not significantly lower than nonoperated controls. Conclusion: A DBM enhanced with MSCs can augment rotator cuff healing at 6 weeks and restore bone mineral density at the enthesis to its preinjury levels. Clinical Relevance: Biological augmentation of rotator cuff repair with a DBM and MSCs may reduce the incidence of retears, although further studies are required to determine its effectiveness.


2020 ◽  
Vol 14 (3) ◽  
pp. 265-272
Author(s):  
Atsushi Ikeura ◽  
Taketoshi Kushida ◽  
Kenichi Oe ◽  
Yoshihisa Kotani ◽  
Muneharu Ando ◽  
...  

Study Design: Biomechanical study.Purpose: To assess the correlation between the computed tomography (CT) values of the pedicle screw path and screw pull-out strength.Overview of Literature: The correlation between pedicle screw pull-out strength and bone mineral density has been well established. In addition, several reports have demonstrated a correlation between bone mineral density and CT values. However, no previous biomechanical studies investigated the correlation between CT values and pedicle screw pull-out strength.Methods: Sixty fresh-frozen lumbar vertebrae from 6-month-old pigs were used. Before screw insertion, the CT values of the screw path were obtained for each sample. Specimens were then randomly divided into three equal groups. Each group had one of three pedicle screws inserted: 4.0-mm LEGACY (4.0-LEG), 4.5-mm LEGACY (4.5-LEG), or 4.5-mm SOLERA (4.5-SOL) (all from Medtronic Sofamor Danek Inc., Memphis, TN, USA). Each screw had a consistent 30-mm thread length. Axial pull-out testing was performed at a rate of 1.0 mm/min. Correlations between the CT values and pedicle screw pull-out strength were evaluated using Pearson’s correlation coefficient analysis.Results: The correlation coefficients between the CT values of the screw path and pedicle screw pull-out strength for the 4.0-LEG, 4.5-LEG, and 4.5-SOL groups were 0.836 (<i>p</i> <0.001), 0.780 (<i>p</i> <0.001), and 0.873 (<i>p</i> <0.001), respectively. Greater CT values were associated with greater screw pull-out strength.Conclusions: The CT values of the screw path were strongly positively correlated with pedicle screw pull-out strength, regardless of the screw type and diameter, suggesting that the CT values could be clinically useful for predicting pedicle screw pull-out strength.


2014 ◽  
Vol 25 (6) ◽  
pp. 1714-1720 ◽  
Author(s):  
Julian L. Wichmann ◽  
Christian Booz ◽  
Stefan Wesarg ◽  
Ralf W. Bauer ◽  
J. Matthias Kerl ◽  
...  

2017 ◽  
Vol 9 (3) ◽  
pp. 178-187 ◽  
Author(s):  
Tanujan Thangarajah ◽  
Frederick Henshaw ◽  
Anita Sanghani-Kerai ◽  
Simon M. Lambert ◽  
Catherine J. Pendegrass ◽  
...  

2008 ◽  
Vol 16 (5) ◽  
pp. 504-510 ◽  
Author(s):  
Matthias F. Pietschmann ◽  
Valerie Fröhlich ◽  
Andreas Ficklscherer ◽  
Jörg Hausdorf ◽  
Sandra Utzschneider ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document