A Synthetic Graft With Multilayered Co-Electrospinning Nanoscaffolds for Bridging Massive Rotator Cuff Tear in a Rat Model

2020 ◽  
Vol 48 (8) ◽  
pp. 1826-1836 ◽  
Author(s):  
Shuang Cong ◽  
Yaying Sun ◽  
Jinrong Lin ◽  
Shaohua Liu ◽  
Jiwu Chen

Background: Graft bridging is used in massive rotator cuff tear (MRCT); however, the integration of graft-tendon and graft-bone is still a challenge. Hypothesis: A co-electrospinning nanoscaffold of polycaprolactone (PCL) with an “enthesis-mimicking” (EM) structure could bridge MRCT, facilitate tendon regeneration, and improve graft-bone healing. Study Design: Controlled laboratory study. Methods: First, we analyzed the cytocompatibility of the electrospinning nanoscaffolds, including aligned PCL (aPCL), nonaligned PCL (nPCL), aPCL–collagen I, nPCL–collagen II, and nPCL-nanohydroxyapatite (nHA). Second, for the EM condition, nPCL–collagen II and nPCL-nHA were electrospun layer by layer at one end of the aPCL–collagen I; for the control condition, the nPCL was electrospun on the aPCL. In 40 mature male rats, resection of both the supraspinatus and infraspinatus tendons was performed to create MRCT, and the animals were divided randomly into EM and control groups. In both groups, one end of the layered structure was fixed on the footprint of the rotator cuff, whereas the other end of the layered structure was sutured with the tendon stump. The animals were euthanized for harvesting of tissues for histologic and biomechanical analysis at 4 weeks or 8 weeks postoperatively. Results: All scaffolds showed good cytocompatibility in vitro. The graft-tendon tissue in the EM group had more regularly arranged cells, denser tissue, a significantly higher tendon maturing score, and more birefringence compared with the control group at 8 weeks after operation. Newly formed fibrocartilage could be observed at the graft-bone interface in both groups by 8 weeks, but the EM group had a higher graft-bone healing score and significantly more newly formed fibrocartilage than the control group. An enthesis-like structure with transitional layers was observed in the EM group at 8 weeks. Biomechanically, the values for maximum failure load and stiffness of the tendon-graft-bone complex were significantly higher in the EM group than in the control group at 8 weeks. Conclusion: The co-electrospinning nanoscaffold of aPCL–collagen I could be used as a bridging graft to improve early graft-tendon healing for MRCT in a rat model and enhance early enthesis reconstruction in combination with a multilayered structure of nPCL–collagen II and nPCL-nHA. Clinical Relevance: We constructed a graft to bridge MRCT, enhance graft-tendon healing and graft-bone healing, and reconstruct the enthesis structure.

2019 ◽  
Vol 47 (5) ◽  
pp. NP34-NP35
Author(s):  
Mengcun Chen ◽  
Snehal S. Shetye ◽  
Julianne Huegel ◽  
Corinne N. Riggin ◽  
Daniel J. Gittings ◽  
...  

2020 ◽  
Vol 48 (9) ◽  
pp. 2161-2169
Author(s):  
Dong Min Kim ◽  
In Kyoung Shim ◽  
Myung Jin Shin ◽  
Jae Hee Choi ◽  
Yu Na Lee ◽  
...  

Background: Tearing and degeneration of the rotator cuff at the tendon-to-bone junction are common in adults aged ≥50 years. Few studies have reported on the relationship between estrogen and the rotator cuff enthesis. In addition to preventing bone loss, selective estrogen receptor modulators have been shown to improve tendon and muscle quality. Purpose: To evaluate the effects of raloxifene (RLX) and vitamin D on rotator cuff tendon-to-bone healing in a rat model. Study Design: Controlled laboratory study. Methods: A total of 29 female rats (58 shoulders) were assigned to 4 groups: (1) control group, (2) ovariectomy (OVX)–only group, (3) no RLX group (OVX and rotator cuff repair [RCR]), and (4) RLX group (OVX, RCR, and RLX). Rats that did not undergo rotator cuff tear (RCT) surgery were divided into the control and OVX-only groups according to OVX surgery. Rats that underwent RCT surgery and RCR were divided into the no RLX and RLX groups according to RLX and vitamin D administration. An estrogen-deficient state was induced by OVX at 12 weeks of age. Bone mineral density (BMD) and trabecular bone characteristics were measured by micro–computed tomography, and healing of the tendon-to-bone junction was evaluated by biomechanical testing, histomorphometry, and micro–magnetic resonance imaging (MRI). Results: The mean final body weight (BW; 461.6 ± 47.3 g) of the OVX-only group was significantly higher and BMD (0.25 ± 0.07 g/cm3) was significantly lower ( P < .001) than the mean final BW (338.5 ± 35.1 g) and BMD (0.48 ± 0.05 g/cm3) of the control group. In contrast, the RLX group showed that the BW (369.6 ± 35.8 g) and BMD (0.41 ± 0.08 g/cm3) were not significantly different from the control group. The RLX group had a significantly higher histomorphometric total score (8.50 ± 1.05) than the no RLX group (4.83 ± 2.48). On biomechanical testing, the RLX group (29.7 ± 9.1 N) showed a significantly higher load to failure than the no RLX group (19.4 ± 8.8 N). On micro-MRI, the RLX group had a more homogeneous low signal and tendon continuity than the no RLX group. Conclusion: The combination treatment of RLX and vitamin D prevented a decrease in local BMD (greater tuberosity of the proximal humerus) and enhanced tendon-to-bone healing of the rotator cuff in a rat model. Clinical Relevance: This study induced an estrogen-deficient state similar to the human postmenopausal state and used drugs that are actually being prescribed in a clinical situation.


Medicina ◽  
2021 ◽  
Vol 57 (4) ◽  
pp. 305
Author(s):  
José M. Silberberg ◽  
Alessandro Nilo ◽  
Jorge Roces-García

Background and objectives: Massive rotator cuff tears compromise shoulder mobility function and cannot be directly repaired. Latissimus dorsi tendon transfer (LDTT) is a therapeutic alternative suitable for the treatment of rotator cuff tears that helps to restore external shoulder rotation. Cadaver models have been used for studying the effects of LDTT and procedural variations, but, to the best of our knowledge, none of them have been validated. The aim of our study was to validate a novel cadaver model while verifying the effects of LDTT on external rotation. Materials and Methods: Two groups were included in the study: a cadaver group and a control group made up of healthy volunteers, which were used for the validation of the cadaver model. Baseline external rotation measurements were performed with both groups, after which a massive rotator cuff tear was inflicted and repaired with LDTT in the cadaver group. Their postoperative external rotation was evaluated using three different tests. Results: No statistically significant differences were found between the baseline measurements of the two groups, and postoperative external rotation was significantly higher after LDTT in all cases but one. Conclusions: Cadaver models were validated, since they had a similar preoperative external rotation to healthy volunteers. Moreover, they allowed us to demonstrate the effect of LDTT on external shoulder rotation.


Author(s):  
Surendra Umesh Kamath ◽  
Sunil Murthy

Background:  Rotator cuff tear are one of most common orthopedic musculoskeletal problem gaining importance due to large health scale expenditure. Causes of rotator cuff tears are multifactorial and unclear.  Previous studies have suggested relation between elevated serum lipid profile and rotator cuff tear in western population. We therefore undertook study in our Indian population to correlate association of hypercholesterolemia with rotator cuff tear.Objective: To find association of rotator cuff pathology with hypercholesterolemia in Indian patients.Materials and methods: After obtaining clearance from institutional ethics committee. We prospectively collected fasting lipid samples of population who came to our hospitals with complaints of shoulder pain during our study period. 50 patients had rupture of rotator cuff which was confirmed by ultrasound of involved shoulder. 50 were seen for non-cuff related complaints.  We followed strict inclusion and exclusion criteria.Results: Total cholesterol, Triglycerides and low density lipoprotein concentration of patients with rotator cuff tendon tear were on higher side than control group. High density lipoprotein trend showed being lower than control group.  21 of 50 (42%) had high cholesterol (total cholesterol greater than 240mg/dl) than compared to 18 of 50 (36%) in control group. however P value=0.539 and showed no statistical significance between groups.Conclusion: In Indian population there was no correlation between hypercholesterolemia and rotator cuff tear which is statistically significant.Key words Rotator cuff tear, Hypercholesterolemia, Indian population.   


2016 ◽  
pp. 185-204
Author(s):  
Naoki Suenaga ◽  
Naomi Oizumi ◽  
Hiroshi Yamaguchi ◽  
Tomoya Matsuhashi ◽  
Noboru Taniguchi