Resolution of a Mobile Right Atrial Thrombus Complicating Acute Pulmonary Embolism With Low-Dose Tissue Plasminogen Activator in a Patient With Recent Craniotomy

2016 ◽  
Vol 31 (9) ◽  
pp. 618-621 ◽  
Author(s):  
Amisha K. Patel ◽  
Aarya Kafi ◽  
Antonio Bonet ◽  
Shelly M. Shapiro ◽  
Scott S. Oh ◽  
...  
2014 ◽  
Vol 30 (10) ◽  
pp. 739-743 ◽  
Author(s):  
NW Shammas ◽  
R Padaria ◽  
G Ahuja

Objective Right atrial thrombus in the setting of a large pulmonary embolus is rare and is associated with serious adverse events. This case report presents the role played by EKOS EkoSonic ultrasound system in successfully treating right atrial thrombus and massive pulmonary embolism. Case report A 69-year-old female presented with a massive pulmonary embolus and a large mobile right atrial thrombus. She was treated with catheter-directed lysis using the EKOS EkoSonic ultrasound system and tissue plasminogen activator, with complete resolution of her right atrial thrombus and a marked improvement in her pulmonary embolus and hemodynamics. Conclusion This case report provides a new and an effective option to treat right atrial thrombus associated with a large pulmonary embolus leading to a good outcome.


VASA ◽  
2014 ◽  
Vol 43 (6) ◽  
pp. 450-458 ◽  
Author(s):  
Julio Flores ◽  
Ángel García-Avello ◽  
Esther Alonso ◽  
Antonio Ruíz ◽  
Olga Navarrete ◽  
...  

Background: We evaluated the diagnostic efficacy of tissue plasminogen activator (tPA), using an enzyme-linked immunosorbent assay (ELISA) and compared it with an ELISA D-dimer (VIDAS D-dimer) in acute pulmonary embolism (PE). Patients and methods: We studied 127 consecutive outpatients with clinically suspected PE. The diagnosis of PE was based on a clinical probability pretest for PE and a strict protocol of imaging studies. A plasma sample to measure the levels of tPA and D-dimer was obtained at enrollment. Diagnostic accuracy for tPA and D-dimer was determined by the area under the receiver operating characteristic (ROC) curve. Sensitivity, specificity, predictive values, and the diagnostic utility of tPA with a cutoff of 8.5 ng/mL and D-dimer with a cutoff of 500 ng/mL, were calculated for PE diagnosis. Results: PE was confirmed in 41 patients (32 %). Areas under ROC curves were 0.86 for D-dimer and 0.71 for tPA. The sensitivity/negative predictive value for D-dimer using a cutoff of 500 ng/mL, and tPA using a cutoff of 8.5 ng/mL, were 95 % (95 % CI, 88–100 %)/95 % (95 % CI, 88–100 %) and 95 % (95 % CI, 88–100 %)/94 %), respectively. The diagnostic utility to exclude PE was 28.3 % (95 % CI, 21–37 %) for D-dimer and 24.4 % (95 % CI, 17–33 %) for tPA. Conclusions: The tPA with a cutoff of 8.5 ng/mL has a high sensitivity and negative predictive value for exclusion of PE, similar to those observed for the VIDAS D-dimer with a cutoff of 500 ng/mL, although the diagnostic utility was slightly higher for the D-dimer.


Sign in / Sign up

Export Citation Format

Share Document