Update of the Toronto Western Hospital Technique for Continuous Ambulatory Peritoneal Dialysis (CAPD)

1980 ◽  
Vol 1 (4) ◽  
pp. 38-40 ◽  
Author(s):  
Sheila Clayton ◽  
Charlotte Quinton ◽  
Dimitrios G. Oreopoulos
1992 ◽  
Vol 12 (4) ◽  
pp. 384-389 ◽  
Author(s):  
Zbylut J. Twardowski ◽  
Barbara F. Prowant ◽  
W. Kirt Nichols ◽  
Karl D. Nolph ◽  
Ramesh Khanna

From the beginning of our continuous ambulatory peritoneal dialysis (CAPD) program in January 1977 until June 1985, we used Tenckhoff and Toronto Western Hospital catheters. Throughout these years catheter survival probabilities of about 30% at three years persisted unchanged and were similar to survival probabilities reported by the National CAPD Registry special survey for these catheters. The first improvement in catheter results regarding leaks was noted after the adoption of lateral catheter insertion. Malfunction was less using swan neck prototypes from August 1985 to April 1986. The latter catheters were made of 80° are angle tubing between 8.5 cm spaced cuffs and were inserted in a reversed U-shape tunnel with the incision at the top of the tunnel. The use of these catheters was abandoned because of high cuff extrusion and exit infection rates. The next generation of swan neck catheters, the swan neck Missouri 2 and 3 catheters with straight intraperitoneal segments, improved the results dramatically. These catheters were made of 180° are angletubing between 5 or 3 cm spaced cuffs. The estimated survival probability of 61% at three years more than doubled compared to previously used catheters. Recently we modified the intraperitoneal segment of the catheters, replacing the straight segment with a coiled one. These modified catheters, the swan neck Missouri coiled catheters, have been used exclusively since February 1990. In addition to an acceptable survival probability of 88% at one year, there are two major advantages of these catheters, the same as for other coiled catheters: elimination of infusion pain due to a jet effect and pain related to straight catheter tip pressure on the peritoneum experienced by some patients.


1993 ◽  
Vol 13 (3) ◽  
pp. 198-200 ◽  
Author(s):  
Cornelis H. Schröder ◽  
René S.V.M. Severijnen ◽  
Maria C.J.W. De Jong ◽  
Leo A.H. Monnens

Objective Chronic tunnel infections often necessitate the removal of the continuous ambulatory peritoneal dialysis (CAPD) catheter. Most published studies advocate postponing the insertion of a new catheter for several weeks. For young children it will be particularly difficult to wait this length of time, since vascular access may be cumbersome, and hemodialysis may not be well tolerated. The present study describes the results of the simultaneous removal and replacement of the CAPD catheter. .Design: Twenty-three Toronto Western Hospital II catheters were inserted in 17 children because of infectious complications (21 chronic tunnel infections; 2 recurrent peritonitis) in a single operation under appropriate antibiotic prophylaxis. The new catheter was inserted at the contralateral side of the abdomen with the deep cuff in the midline, using the same entrance to the peritoneal cavity. Dialysis was resumed immediately after the operation. Setting A university pediatric dialysis unit. Patients Seventeen children (mean age 3.7 years; range 1.0–8.5 years) were studied. In this group 23 catheters were replaced. Results In four cases a relapse of the tunnel infection was observed within 3 months. All other cases remained free of infection for a period of at least 6 months. The main causative microorganism was Staphylococcus aureus (15 occurrences). Conclusion It is not necessary to interrupt peritoneal dialysis for the replacement of a CAPD catheter because of infectious complications.


Author(s):  
William J. Lamoreaux ◽  
David L. Smalley ◽  
Larry M. Baddour ◽  
Alfred P. Kraus

Infections associated with the use of intravascular devices have been documented and have been reported to be related to duration of catheter usage. Recently, Eaton et al. reported that Staphylococcus epidermidis may attach to silastic catheters used in continuous ambulatory peritoneal dialysis (CAPD) treatment. The following study presents findings using scanning electron microscopy (SEM) of S. epidermidis adherence to silastic catheters in an in vitro model. In addition, sections of polyvinyl chloride (PVC) dialysis bags were also evaluated by SEM.The S. epidermidis strain RP62A which had been obtained in a previous outbreak of coagulase-negative staphylococcal sepsis at local hospitals was used in these experiments. The strain produced surface slime on exposure to glucose, whereas a nonadherent variant RP62A-NA, which was also used in these studies, failed to produce slime. Strains were grown overnight on blood agar plates at 37°C, harvested from the surface and resuspended in sterile saline (0.85%), centrifuged (3,000 rpm for 10 minutes) and then washed twice in 0.1 M phosphate-buffered saline at pH 7.0. Organisms were resuspended at a concentration of ca. 106 CFU/ml in: a) sterile unused dianeal at 4.25% dextrose, b) sterile unused dianeal at 1.5% dextrose, c) sterile used dialysate previously containing 4.25% dextrose taken from a CAPD patient, and d) sterile used dialysate previously containing 1.5% dextrose taken from a CAPD patient.


Mycoses ◽  
2002 ◽  
Vol 45 (3-4) ◽  
pp. 120-122 ◽  
Author(s):  
S. Cinar ◽  
A. Nedret Koc ◽  
H. Taskapan ◽  
A. Dogukan ◽  
B. Tokgoz ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document