Modeling and control of heat pump system for battery electric buses

Author(s):  
Rabih Al Haddad ◽  
Hussein Basma ◽  
Charbel Mansour

Given the continuous tightening of emissions regulations on vehicles, battery-electric buses (BEB) play an essential role in the transition toward cleaner transport technologies, as they represent the most promising solution to replace diesel buses and reduce their environmental impact in the short term. However, heating the bus cabin leads to a considerable increase in energy consumption under cold weather conditions, which significantly reduces the driving range, given the limited battery capacity. Heat pumps (HP) are the primary heating technology used in BEB for their improved consumption performance compared to other technologies. Therefore, this study aims at optimizing the coefficient of performance (COP) of an HP system in a BEB for maximizing the bus electric driving range under cold weather conditions while maintaining satisfactory thermal comfort levels for passengers. Accordingly, an HP model is developed and integrated into an electric bus model using Dymola. A genetic algorithm (GA) based controller is proposed to find the optimal combination of the HP operating parameters, namely the compressor speed, the air mass flow rate at the inlet of the condenser, and the recirculation rate in order to maximize the system’s COP, and extend the BEB driving at different external temperatures, and as a function of the passengers’ occupancy levels. Results are carried under transient and steady-state operating conditions and show that the proposed GA-based controller saves up to 39% of the HP energy consumption as compared to the conventional HP control strategy, and therefore, enhances the BEB driving range up to 17%.

HortScience ◽  
1994 ◽  
Vol 29 (4) ◽  
pp. 249a-249
Author(s):  
Eric A. Lavoie ◽  
Damien de Halleux ◽  
André Gosselin ◽  
Jean-Claude Dufour

The main objective of this research was to produce a simulated model that permitted the evaluation of operating costs of commercial greenhouse tomato growers with respect to heating methods (hot air, hot water, radiant and heat pumps) and the use of artificial lighting for 1991 and 1992. This research showed that the main factors that negatively influence profitability were energy consumption during cold periods and the price of tomatoes during the summer season. The conventional hot water system consumed less energy than the heat pump system and produced marketable fruit yields similar to those from the heat pump system. The hot water system was generally more profitable in regards to energy consumption and productivity. Moreover, investment costs were less; therefore, this system gives best overall financial savings. As for radiant and hot air systems, their overall financial status falls between that of the hot water system and the heat pump. The radiant system proved to be more energy efficient that the hot air system, but the latter produced a higher marketable fruit yield over the 2-year study.


Energies ◽  
2020 ◽  
Vol 13 (17) ◽  
pp. 4306 ◽  
Author(s):  
Zhongting Hu ◽  
Sheng Zhang ◽  
Wenfeng Chu ◽  
Wei He ◽  
Cairui Yu ◽  
...  

The present work investigated a solar assisted heat pump system for drying Chinese wolfberry. The kinetic characteristic was firstly analyzed through a series of lab experiments. It was concluded that the Page model was the most suitable for predicting the heat and mass transfer of the wolfberry. Based on the wolfberry kinetic model, solar collector model and chamber air model, the coupled drying system model was developed. The accuracy of the mathematic model was determined through comparing with the preliminary experimental results. The influence of operating conditions on the thermal and energy performance of the dryer for the different operating mode was discussed. The drying weight of no more than 75 kg may be preferable in the stand-alone solar drying mode, and less than 15 h was needed to be dried. The electric energy consumption in the solar assisted the heat pump drying mode was lower than that in the stand-alone heat pump mode, and it was recommended that about 50 kg of wolfberry to be dried in the solar assisted heat pump system. Compared to the autumn drying, the reduction in the electric energy consumption was around 9.1 kWh during the 11 h summer drying process. The obtained results demonstrated the feasibility of the combined system for drying wolfberry, and also can provide the basic theoretical and experimental data support for the following research.


Energies ◽  
2020 ◽  
Vol 13 (3) ◽  
pp. 662 ◽  
Author(s):  
Hannah Licharz ◽  
Peter Rösmann ◽  
Manuel S. Krommweh ◽  
Ehab Mostafa ◽  
Wolfgang Büscher

This study describes a 70-day investigation of three identical groundwater heat pumps (GWHP) for heating two pig houses located on the same farm in West Germany. Two of the three GWHPs were installed in a piglet-rearing barn, the third in a farrowing barn. All three heat pumps were fed from the same extraction well. The aim of this study was firstly the empirical performance measurement of the GWHP systems and secondly the energetic evaluation of the systems on barn level by calculating the coefficient of performance (COP). Three different assessment limits were considered in order to better identify factors influencing the COP. In total, the heat pumps supplied thermal energy of 47,160 kWh (piglet-rearing barn) and 36,500 kWh (farrowing barn). Depending on the assessment limit considered, the COP in piglet-rearing barn and farrowing barn ranged between 2.6–3.4 and 2.5–3.0, respectively. A significant factor influencing the COP is the amount of electrical current required to operate the groundwater feeding pump. The average groundwater flow rate was 168.4 m3 d−1 (piglet-rearing barn) and 99.1 m3 d−1 (farrowing barn). In conclusion, by using energy from groundwater, GWHPs have the potential to substitute fossil fuels, thus saving them and avoiding CO2 emissions.


Author(s):  
AA Ammar ◽  
K Sopian ◽  
M Mohanraj

In this research, a photovoltaic-thermal collector assisted heat pump has been developed and tested its performance under the tropical climatic conditions of Malaysia. The refrigerants such as, R134a and R1234yf were selected based on its thermodynamic and thermo-physical properties. The temperature of the photovoltaic module was theoretically predicted under the influence of tube diameter, tube spacing and refrigerant mass flow rate. Further, the energy performance of the photovoltaic-thermal evaporator and the heat pump system are investigated experimentally. Finally, the economical feasibility of the photovoltaic-thermal collector evaporator was assessed for the period of 20 years. The results showed that, the tube spacing and diameter of the copper tubes used in the photovoltaic-thermal evaporator/collector using R134a and R1234yf were optimized to 80 mm and 12.7 mm, respectively. It was observed that, during the clear sunny day, the average photovoltaic module temperature was reduced to 30.9 °C under the influence of panel cooling using refrigerant. The output of the panel was enhanced by 21%–44% with increase in solar radiation from 400 W/m2 to 1000 W/m2. The coefficient of performance of the heat pump was varied from 4.8 to 6.84 with an average coefficient of performance of 5.8 during clear sunny days. The life cycle economic analysis indicated that, the photovoltaic-thermal collector evaporator assisted heat pump has a payback period of 3 years, whereas the reference photovoltaic system has a payback period of 8 years.


2019 ◽  
Vol 85 ◽  
pp. 07014
Author(s):  
Gheorghe Ilisei ◽  
Tiberiu Catalina ◽  
Marian Alexandru ◽  
Robert Gavriliuc

Underground energy sources are becoming increasingly popular and now geothermal heat pumps are frequently used to heat/cool different types of buildings, including for solar passive houses. This article aims at giving a contribution in the development of the thermal modelling of borehole heat storage systems, investigating the possibility of a GSHP (ground source heat pump) implementation with vertical boreholes in a solar passive house. A case study analysing a residential solar passive house is presented as a suitable modelling tool for the estimation of the thermal behaviour of GSHP systems by combining the outcome from different modelling programs. The software DesignBuilder, Earth Energy Designer and a sizing method for borehole’s length are used for producing the numerical results. The results highlight that the length of the borehole, a major index in estimating the system’s cost, is directly influenced by fundamental variables like thermal conductivity of grout or soil. Additionally, correlations between these parameters and the coefficient of performance of GSHP were made. Furthermore, the length of borehole is very important as it is responsible for almost half of the total installation cost and triggered a difference in electricity consumption of the GSHP up to 14%.


Processes ◽  
2019 ◽  
Vol 7 (9) ◽  
pp. 553 ◽  
Author(s):  
Muhammad Kashif Shahzad ◽  
Mirza Abdullah Rehan ◽  
Muzaffar Ali ◽  
Azeem Mustafa ◽  
Zafar Abbas ◽  
...  

This paper presents an experimental evaluation of a closed loop lake water heat pump (LWHPs) system based on the slinky coiled configuration. Initially, a mathematical model is developed in the Engineering Equation Solver (EES) for the heat pump system and the submerged coils in a lake. System performance is determined for the submerged slinky copper coils under the various operating conditions. Afterwards, parametric analysis is performed considering different influencing parameters, such as the lake water temperature, ambient temperature, and mass flow rate of the circulating fluid at constant lake depth of 4 ft. The experimental setup is developed for 3.51 kW cooling capacity after cooling load calculation for a small room. In the current study, slinky copper coils are used to exchange heat with lake water. The experimental setup is installed in Taxila, Pakistan, and the system’s performance is analyzed during selected days. After experimentation based on hourly and daily operation characteristics, it is observed that the lake water temperature has significant influence on the heat transfer rate between slinky coil and lake water. While the lake water temperature in summer decreases and increases in winter with the depth. The resulted daily average coefficient of performance (COP) of the system is within the range of 3.24–3.46 during the selected days of cooling season. Based on these results, it can be concluded that the LWHP systems can be considered a viable solution for Pakistan having a well-established canal system.


Author(s):  
Kazuaki Yazawa ◽  
Vernon K. Wong ◽  
Morten Boje Blarke ◽  
Ali Shakouri

We present preliminary proof-of-concept experimental results on a thermoelectric heat pump system. In our previous work we proposed a thermal battery which would benefit from state-of-the-art heat pumps in order to provide useful cooling and heating. The preliminary analysis demonstrated the benefit of using excess electricity from intermittent renewable power sources, e.g. solar or wind, and converting it into the hot and cold water storage tanks typically used for residential applications. The time response of mechanical heat pumps is slow and their efficiency suffers from fluctuating electricity supplies. To overcome this issue, we propose thermoelectric (TE) co-generation systems that benefit from their fast response and scalability. Modeling has been performed to optimize the TE module for the effective harvesting of both heat and electricity from intermittent solar energy with response times in minutes. Throughout the modeling and experiments, the combined coefficient-of-performance (COP) is found to be 1.6, while the hot water is 52.5°C and cold water is 16.5°C, both from 22.3°C. The COP is moderate, but due to its quick response, the accumulated energy harvested by this thermoelectric system could be comparable to mechanical compressor systems.


2017 ◽  
Vol 25 (03) ◽  
pp. 1750024 ◽  
Author(s):  
Samuel Boahen ◽  
Kwang Ho Lee ◽  
Soolyeon Cho ◽  
Jong Min Choi

Heating and cooling systems contribute greatly to the energy consumption and CO2 emissions of many countries. Ground source heat pumps (GSHP) are promising energy saving systems for residential, commercial or industrial heating or cooling purposes. A method to estimate the energy consumption and CO2 emission of GSHPs is therefore very eminent. This paper reviews the methodology to calculate the energy consumption and CO2 emission of GSHPs. The discussed methodology is then used to compare the energy consumption and CO2 emission of an open-loop and closed-loop GSHP using data from field test. It is observed that the open-loop GSHP saves 28% energy and reduces CO2 by 28% than the closed-loop GSHP in the cooling season. When used for both cooling and heating purposes in the year, the open-loop GSHP saves about 6% energy and reduces about 6% of CO2 emission than the closed-loop GSHP.


Energies ◽  
2020 ◽  
Vol 13 (12) ◽  
pp. 3269 ◽  
Author(s):  
Zhongbao Liu ◽  
Fengfei Lou ◽  
Xin Qi ◽  
Yiyao Shen

Air source heat pumps (ASHPs) are widely recognized as energy-saving and environmentally friendly heating and air-conditioning equipment with broad applications. However, when conventional ASHPs are operated at a low ambient temperature, they suffer from problems such as high discharge temperature and low heating efficiency. To address these problems, this study designed a new type of dual evaporator combined with a compressor casing thermal storage heat pump system (DE-CCTS) on the basis of a low-temperature air source heat pump water heater with enhanced vapor injection (EVI). The proposed DE-CCTS used thermal storage phase change material (PCM), which was filled in the secondary evaporator (the thermal storage heat exchanger), to recover the waste heat of the compressor casing. Unlike that in the original system under different ambient temperatures, the suction temperature increased by 0.1–1 °C, the discharge temperature decreased by 0.1–0.5 °C, and the coefficient of performance (COP) of DE-CCTS increased by 0.85–4.72% under the proposed system. These effects were especially evident at low temperatures.


Energies ◽  
2018 ◽  
Vol 11 (1) ◽  
pp. 211 ◽  
Author(s):  
Piljae Im ◽  
Xiaobing Liu ◽  
Hugh Henderson

The wastewater leaving from homes and businesses contains abundant low-grade energy, which can be utilized through heat pump technology to heat and cool buildings. Although the energy in the wastewater has been successfully utilized to condition buildings in other countries, it is barely utilized in the United States, until recently. In 2013, the Denver Museum of Nature & Science at Denver, the United States implemented a unique heat pump system that utilizes recycled wastewater from a municipal water system to cool and heat its 13,000 m2 new addition. This recycled water heat pump (RWHP) system uses seven 105 kW (cooling capacity) modular water-to-water heat pumps (WWHPs). Each WWHP uses R-410A refrigerant, has two compressors, and can independently provide either 52 °C hot water (HW) or 7 °C chilled water (CHW) to the building. This paper presents performance characterization results of this RWHP system based on the measured data from December 2014 through August 2015. The annual energy consumption of the RWHP system was also calculated and compared with that of a baseline Heating, Ventilation, and Air Conditioning (HVAC) system which meets the minimum energy efficiencies that are allowed by American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) 90.1-2013. The performance analysis results indicate that recycled water temperatures were favorable for effective operation of heat pumps. As a result, on an annual basis, the RWHP system avoided 50% of source energy consumption (resulting from reduction in natural gas consumption although electricity consumption was increased slightly), reduced CO2 emissions by 41%, and saved 34% in energy costs as compared with the baseline system.


Sign in / Sign up

Export Citation Format

Share Document