scholarly journals Smartphone ECG Monitoring System Helps Lower Emergency Room and Clinic Visits in Post–Atrial Fibrillation Ablation Patients

2020 ◽  
Vol 14 ◽  
pp. 117954682090150 ◽  
Author(s):  
Mossab Aljuaid ◽  
Qussay Marashly ◽  
Jad AlDanaf ◽  
Ibrahim Tawhari ◽  
Michel Barakat ◽  
...  

Aim: To evaluate the effectiveness of using a smartphone-based electrocardiography (ECG) monitoring device (ECG Check) on the frequency of clinic or emergency room visits in patients who underwent ablation of atrial fibrillation (AF). Methods: Two groups of patients were identified and compared: The conventional monitoring group (CM group) included patients who were prescribed conventional event monitoring or Holter monitoring systems. The ECG Check group (EC group) included patients who were prescribed the ECG Check device for continuous monitoring in addition to conventional event monitoring. The primary outcome was the number of patient visits to clinic or emergency room. The feasibility, accuracy, and detection rate of mobile ECG Check were also evaluated. Results: Ninety patients were studied (mean age: 66.2 ± 11 years, 64 males, mean CHA2DS2-VASc score: 2.6 ± 2). In the EC group, forty-five patients sent an average of 52.8 ± 6 ECG records for either routine monitoring or symptoms of potential AF during the follow-up period. The rhythm strips identified sinus rhythm (84.7%), sinus tachycardia (8.4%), AF (4.2%), and atrial flutter (0.9%). Forty-two EC transmissions (1.8%) were uninterpretable. Six patients (13%) in the EC group were seen in the clinic or emergency room over a 100-day study period versus 16 (33%) in the standard care arm ( P value < 0.001). Conclusions: Use of smartphone-based ECG monitoring led to a significant reduction in AF-related visits to clinic or emergency department in the postablation period.

2021 ◽  
Vol 8 (7) ◽  
pp. 81
Author(s):  
Andrzej Kułach ◽  
Milena Dewerenda ◽  
Michał Majewski ◽  
Anetta Lasek-Bal ◽  
Zbigniew Gąsior

Introduction: Silent atrial fibrillation (AF) is a common cause of cryptogenic ischemic stroke (CIS). The 24-h-Holter is insufficient to reveal an occult arrhythmic cause of stroke and the strategy to select the patients for long-term monitoring is missing. Objectives: The aim of the study was to evaluate 7-day-Holter monitoring to identify cases with the arrhythmic cause of stroke in CIS patients in whom 24-h-Holter was free from arrhythmia, and to assess the relation between supraventricular (SV) runs in baseline Holter and the incidence of AF in a 3-year follow-up period. Methods: 78 patients (aged 60 ± 9 years, 45 males) with CIS and no arrhythmic findings in 24-h-Holter were enrolled. All patients had 7-day-Holter monitoring after stroke and were followed up for 36 months, and then 7-day Holter was repeated. We assessed SV runs (≥5 QRS) in the initial 7-day Holter and analyzed the relation of the findings with clinical characteristics of novel AF episodes revealed early after stroke and during a 3-year follow-up. Results: Baseline 7-day-Holter revealed SV runs in 36% of patients and AF in 9% of cases. During a 3-year follow-up, 8 additional cases were confirmed, both in standard care and in repeated Holter (a total of 19% of AF cases). There was no difference with regard to CHADS2VASc score (3.6 ± 1.1 vs. 3.4 ± 1.5; p = NS) and left atrium parameters between patients with SV runs and the non-arrhythmic group. Patients with SV runs had a higher incidence of AF both after stroke and in a 3-year follow-up (46% vs. 4%, RR 11.6, p < 0.001). In 8 cases, patent foramen ovale was detected during follow-up. Conclusions: A strategy of baseline 7-day-Holter monitoring after stroke allows for disclosing SV runs in every third case and AF in 9% of stroke survivors. Patients with SV runs have a higher incidence of AF (RR 11.6, p < 0.001) and should be considered for extended continuous ECG monitoring.


TH Open ◽  
2020 ◽  
Vol 04 (04) ◽  
pp. e417-e426
Author(s):  
Carline J. van den Dries ◽  
Sander van Doorn ◽  
Patrick Souverein ◽  
Romin Pajouheshnia ◽  
Karel G.M. Moons ◽  
...  

Abstract Background The benefit of direct oral anticoagulants (DOACs) versus vitamin K antagonists (VKAs) on major bleeding was less prominent among atrial fibrillation (AF) patients with polypharmacy in post-hoc randomized controlled trials analyses. Whether this phenomenon also exists in routine care is unknown. The aim of the study is to investigate whether the number of concomitant drugs prescribed modifies safety and effectiveness of DOACs compared with VKAs in AF patients treated in general practice. Study Design Adult, nonvalvular AF patients with a first DOAC or VKA prescription between January 2010 and July 2018 were included, using data from the United Kingdom Clinical Practice Research Datalink. Primary outcome was major bleeding, secondary outcomes included types of major bleeding, nonmajor bleeding, ischemic stroke, and all-cause mortality. Effect modification was assessed using Cox proportional hazard regression, stratified for the number of concomitant drugs into three strata (0–5, 6–8, ≥9 drugs), and by including the continuous variable in an interaction term with the exposure (DOAC vs. VKA). Results A total of 63,600 patients with 146,059 person-years of follow-up were analyzed (39,840 person-years of DOAC follow-up). The median age was 76 years in both groups, the median number of concomitant drugs prescribed was 7. Overall, the hazard of major bleeding was similar between VKA-users and DOAC-users (hazard ratio [HR] 0.98; 95% confidence interval [CI] 0.87–1.11), though for apixaban a reduction in major bleeding was observed (HR 0.81; 95% CI 0.68–0.98). Risk of stroke was comparable, while risk of nonmajor bleeding was lower in DOAC users compared with VKA users (HR 0.92; 95% CI 0.88–0.97). We did not observe any evidence for an impact of polypharmacy on the relative risk of major bleeding between VKA and DOAC across our predefined three strata of concomitant drug use (p-value for interaction = 0.65). For mortality, however, risk of mortality was highest among DOAC users, increasing with polypharmacy and independent of the type of DOAC prescribed (p-value for interaction <0.01). Conclusion In this large observational, population-wide study of AF patients, risk of bleeding, and ischemic stroke were comparable between DOACs and VKAs, irrespective of the number of concomitant drugs prescribed. In AF patients with increasing polypharmacy, our data appeared to suggest an unexplained yet increased risk of mortality in DOAC-treated patients, compared with VKA recipients.


2018 ◽  
Vol 2018 ◽  
pp. 1-7 ◽  
Author(s):  
Karapet Davtyan ◽  
Victoria Shatakhtsyan ◽  
Hermine Poghosyan ◽  
Alexandr Deev ◽  
Alexey Tarasov ◽  
...  

Introduction. While several studies have compared the radiofrequency current (RFC) and cryoablation for the treatment of patients with atrial fibrillation (AF), no study has monitored the long-term outcomes with the usage of implantable loop recorders (ILRs). Methods. We enrolled 89 consecutive patients with nonvalvular paroxysmal AF (N=44 for RFC and N=45 for cryoballoon). The primary efficacy end point was the assessment of effectiveness for each group (RFC versus cryoballoon) when examining freedom from arrhythmia by monitoring with ECG, Holter, and implantable loop recoder (ILR). The primary safety end point compared rates of adverse events between both groups. The secondary efficacy end point examined the duration of the postablation blanking period from ILR retrieved data. Results. The mean age of the study population was 56.6±10.2 years, and the follow-up duration was 12 months. There were no differences in baseline patient characteristics between groups. At 12 months, the absolute effectiveness (measured by ILR) was 65.9% in the RFC group and 51.1% in the cryoballoon group (OR = 1.85; 95% CI: 0.79–4.35; p=0.157), and the clinical effectiveness (measured by ECG and Holter) was 81.8% in the RFC group and 55.6% in the cryoballoon group (OR = 3.6; 95% CI: 1.37–9.46; p=0.008). There was no difference in safety between both groups. Asymptomatic episodes were significantly more present in the RFC group as measured by ILRs (p<0.010). In cryoballoon group, arrhythmia episodes were recorded equally irrespective of the follow-up method (i.e., ECG and Holter versus ILR (p>0.010)). The blanking period does not seem to be as important in cryoballoon as compared to RFC. Conclusion. RFC and cryoballoon ablation had similar absolute effectiveness at 12 months. ECG and Holter were effective when assessing the efficacy of the cryoballoon ablation; however, in the RFC group, ILR was necessary to accurately assess long-term efficacy.


Circulation ◽  
2015 ◽  
Vol 132 (suppl_3) ◽  
Author(s):  
Xue Zhao ◽  
Jianqiang Hu ◽  
Yan Huang ◽  
Yawei Xu ◽  
Yanzhou Zhang ◽  
...  

Objectives: The aim of this study was to determine the mechanisms and effectiveness of pulmonary antrum radial-linear (PAR) ablation in comparison with pulmonary vein isolation (PVI) in patients with paroxysmal atrial fibrillation (AF) after a long-term follow-up. Background: The one-year follow up data suggested that PAR ablation appeared to have a better outcome over the conventional PVI for paroxysmal AF. Methods: The enrollment occurred between March, 2011, and August, 2011, with the last follow-up in May, 2014. A total of 133 patients with documented paroxysmal AF were enrolled from 5 centers and randomized to PAR group or PVI group. Event ECG recorder and Holter monitoring were conductedduring the follow-up for all patients. Results: The average procedure time was 151±23 min in PAR group and 178±43 min in PVI group ( P <0.001). The average fluoroscopy time was 21±7 min in PAR group and 27±11 min in PVI group ( P= 0.002). AF triggering foci were eliminated in 59 patients (89.4%) in PAR group, whereas, only 4 patients (6.0%) in PVI group (P<0.001).At median 36 (37-35) months of follow-up after single ablation procedure, 43 of 66 patients in PAR group (65%) and 28 of 67 patients in PVI group (42%) had no recurrence of AF off antiarrhythmic drug (AAD) (P=0.007); and 47 of 66 patients in PAR group (71%) and 32 of 67 patients in PVI group (48%) had no recurrence of AF with AAD (P=0.006). At the last follow-up, the burden of AF was significantly lower in PAR group than in PVI group (0.9% ± 2.3% vs 4.9% ± 9.9%;90th percentile, 5.5% vs 19.6%; P=0.008). No major adverse event (death, stroke, PV stenosis) was observed in all the patients except one case of pericardial tamponade. Conclusions: PAR ablation is a simple, safe, and effective strategy for the treatment of paroxysmal AF with better long-term outcome than PVI. PAR ablation might exhibit the beneficial effect on AF management through multiple mechanisms. Registration: ChiCTR-TRC-11001191


Stroke ◽  
2012 ◽  
Vol 43 (suppl_1) ◽  
Author(s):  
H. B Brouwers ◽  
Svetlana Lorenzano ◽  
Lyndsey H Starks ◽  
David M Greer ◽  
Steven K Feske ◽  
...  

Purpose: Hemorrhagic transformation (HT) is a common and potentially devastating complication of ischemic stroke, however its prevalence, predictors, and outcome remain unclear. Early anticoagulation is thought to be a risk factor for HT which raises the clinical question when to (re)start anticoagulation in ischemic stroke patients who have a compelling indication, such as atrial fibrillation. We conducted a prospective cohort study to address this question and to identify association of hemorrhagic transformation with outcome measures in patients with atrial fibrillation in the setting of acute ischemic stroke. Materials and Methods: We performed a prospective study which enrolled consecutive patients admitted with acute ischemic stroke presenting to a single center over a three-year period. As part of the observational study, baseline clinical data and stroke characteristics as well as 3 month functional outcome were collected. For this sub-study, we restricted the analysis to subjects diagnosed with atrial fibrillation. CT and MRI scans were reviewed by experienced readers, blinded to clinical data, to assess for hemorrhagic transformation (using ECASS 2 criteria), microbleeds and infarct volumes in both admission and follow-up scans. Clinical and outcome data were analyzed for association with hemorrhagic transformation. Results: Of 94 patients, 63 had a history of atrial fibrillation (67.0%) and 31 had newly discovered atrial fibrillation (33.0%). We identified HT in 3 of 94 baseline scans (3.2%) and 22 of 48 follow-up scans (45.8%) obtained a median of 3 days post-stroke. In-hospital initiation of either anti-platelet (n = 36; OR 0.34 [95% CI 0.10-1.16], p-value = 0.09) or anticoagulation with unfractionated intravenous heparin or low molecular weight heparin (n = 72; OR 0.25 [95% CI 0.06-1.15], p-value = 0.08) was not associated with HT. Initial NIH Stroke Scale (NIHSS) score (median 13.0 [IQR 15.0] vs. 7.0 [IQR 10.0], p-value = 0.029) and baseline infarct volume (median 17 [IQR 42.03] vs. 5 [IQR 10.95], p-value = 0.011) were significantly higher in patients with HT compared to those without. Hemorrhagic transformation was associated with a significantly higher 48-hour median NIHSS score (20 [IQR 3.0] vs. 2 [IQR 3.25], p-value = 0.007) and larger final infarct volume (81.40 [IQR 82.75] vs. 9.95 [IQR 19.73], p-value < 0.001). Finally, we found a trend towards poorer 3-month modified Rankin Scale scores in subjects with HT (OR 11.25 [95% CI 0.97-130.22], p-value = 0.05). Conclusion: In patients with atrial fibrillation, initial NIHSS score and baseline infarct volume are associated with hemorrhagic transformation in acute ischemic stroke. Early initiation of antithrombotic therapy was not associated with hemorrhagic transformation. Patients with hemorrhagic transformation were found to have a poorer short and long term outcome and larger final infarct volumes.


Neurology ◽  
2017 ◽  
Vol 89 (15) ◽  
pp. 1545-1552 ◽  
Author(s):  
Mark Weber-Krüger ◽  
Constanze Lutz ◽  
Antonia Zapf ◽  
Raoul Stahrenberg ◽  
Joachim Seegers ◽  
...  

Objective:Prolonged ECG monitoring after stroke frequently reveals short paroxysmal atrial fibrillation (pAF) and supraventricular (SV) runs. The minimal duration of atrial fibrillation (AF) required to induce cardioembolism, the relevance of SV runs, and whether short pAF results from cerebral damage itself are currently being debated. We aimed to study the relevance of SV runs and short pAF detected by prolonged Holter ECG after cerebral ischemia during long-term follow-up.Methods:Analysis is from the prospective Find-AF trial (ISRCTN46104198). We included patients with acute cerebral ischemia. Those without AF on admission received 7-day Holter ECG monitoring. We differentiated patients with AF on admission (AF-adm), with pAF (>30 seconds), with SV runs (>5 beats but <30 seconds in a 24-hour ECG interval), and without SV runs (controls). During follow-up, those with baseline pAF received another 7-day Holter ECG to examine AF persistence.Results:A total of 254 of 281 initially included patients were analyzed (mean age 70.0 years, 45.3% female). Forty-three (16.9%) had AF-adm. A total of 211 received 7-day Holter ECG monitoring: 27 (12.8%) had pAF, 67 (31.8%) had SV runs, and 117 (55.5%) were controls. During a mean 3.7 years of follow-up, the SV runs group had more recurrent strokes (p = 0.04) and showed numerically more novel AF (12% vs 5%, p = 0.09) than the controls. Seventy-five percent of the patients with manifest pAF detected after cerebral ischemia still had AF during follow-up (50% paroxysmal, 50% persisting/permanent).Conclusions:Patients with cerebral ischemia and SV runs had more recurrent strokes and numerically more novel AF during follow-up and could benefit from further prolonged ECG monitoring. pAF detected after stroke is not a temporal phenomenon.


2021 ◽  
Vol 8 ◽  
Author(s):  
Long Song ◽  
Chengming Fan ◽  
Hao Zhang ◽  
Hongduan Liu ◽  
Chukwuemeka Daniel Iroegbu ◽  
...  

The safety and efficacy of the Cox-Maze IV procedure (CMP-IV) for situs inversus dextrocardia patients with atrial fibrillation is yet to be determined. Herein, we present the case of a 39-year-old male patient admitted to our cardiac center following progressive exertional dyspnea. The patient was diagnosed with situs inversus dextrocardia, severe mitral regurgitation, and paroxysmal atrial fibrillation. A three-dimensional (3D) heart model printing device embedded with designated ablation lines was used for pre-operative planning. Mitral valvuloplasty, CMP-IV, and tricuspid annuloplasty were performed. The patient had an uneventful recovery and was in sinus rhythm during a 12-month follow-up period using a 24-h Holter monitoring device. The case herein is one of the first to report on adopting the CMP-IV procedure for situs inversus dextrocardia patients with complex valvuloplasty operation. In addition, the 3D printing technique enabled us to practice the Cox-maze IV procedure, given the patient's unique cardiac anatomy.


QJM ◽  
2021 ◽  
Vol 114 (Supplement_1) ◽  
Author(s):  
Mohammed Elnwagy ◽  
Hossam Shokery ◽  
Emad Effat ◽  
Hayam El Damnhory

Abstract Background cerebrovascular stroke is major cause of morbidity and disability. Many causes may contribute to its presence, however. Some patients have none of the identified risk factors, yet face the consequences of stroke or transit ischemic attack. This type of stroke known to be stroke of undetermined source or etiology. It has a high rate of recurrence due to the persistence of the unknown etiology. Paroxysmal atrial fibrillation remains the hidden bottom of an iceberg representing a major part of the causes of ischemic cerebrovascular stroke of undetermined etiology . Aim and Objectives: to determine the prevalence of subclinical atrial fibrillation in patients with ischemic cerebrovascular stroke of undetermined etiology in a population in Egypt by 48h holter monitoring. Patients and Methods Patients diagnosed with acute cerebrovascular stroke of undetermined etiology at the neurology department of Ain Shams university hospitals underwent 48 hours holter monitoring within the first week of the insulting event. Results This study included 50 patients with cryptogenic stroke (CS) who underwent 48 hours holter monitoring. The patients' ages ranged between 22 and 77 years old (mean age 48.46 ± 12.74years). This study included 34 males and 16 females. Their body mass index BMI ranges from 21-35 kg/m2, with mean BMI of 24.78 ± 2.99 kg/m2. Their left atrial diameter ranges from 26-47mm, with mean diameter of 36.08 ± 5.23mm .Eight out of fifty patients newly diagnosed with subclinical atrial fibrillation with prevalence of 16%. There was statistically significant association between the atrial fibrillation (AF) and both age (p value, 009) and left atrial (LA) diameter (p value, 001) .There was an associated finding that need further investigation about the significant association between the ventricular ectopic beat VEB burden and the presence of AF or stroke. Conclusion The prevalence of paroxysmal atrial fibrillation among the population of ischemic stroke of undetermined etiology in a population in Egypt is close to worldwide percentage and the recent met analysis studies of 11%.


Stroke ◽  
2021 ◽  
Vol 52 (Suppl_1) ◽  
Author(s):  
Michael N Sattin ◽  
Zhe Li ◽  
Marko Mrkobrada ◽  
Erin I Spicer

Introduction: Atrial fibrillation (AF) is a major risk factor for cerebral ischemia in North America. Atrial ectopy has been associated with incident AF and increased stroke risk on short-duration ECG monitoring. The objective of this study was to characterize the relationship between the burden of atrial ectopy with future AF, stroke, and cardiovascular events on prolonged ECG monitoring. Methods: A retrospective, observational study was conducted at a single centre enrolling patients >18 years old referred from TIA clinic. Data was collected from 7- and 14-day Holter monitor reports, patient charts, and cardiac investigations. The final sample included 1124 patients; a subgroup of 759 patients had echocardiograms. Univariate and multivariate logistic regression determined the odds ratio (OR) of developing the composite outcome (AF, TIA/stroke, ACS, death) or secondary outcomes (AF or TIA/stroke). Results: The population was high-risk with a mean CHA 2 DS 2 -VASc of 4.0 (±1.8); during 1-year of follow-up, the primary outcome occurred amongst 116 (10.3%) patients. Univariate analysis ORs are displayed in Table 1. There was a statistically significant relationship (p<0.001) between percentage of PACs and the composite outcome (OR 4.066), and AF (11.886) for patients with 2-5% PACs. PAC runs/day was significant if >5/day for AF (OR 5.989, p<0.01) and for the composite (OR 2.231, p<0.05). Long PAC runs (>30 beats) also had significant ORs for AF (2.849, p<0.01) and the composite (5.320, p<0.01). In the subgroup analysis, reduced ejection fraction had an OR of 2.172 (1.407-5.771) for the composite outcome, and atrial dilatation had an OR of 2.778 (1.390-5.551) for AF. Conclusions: Increased burden of atrial ectopy is associated with increased odds of developing AF and a composite of cardiovascular events. Patients with increased ectopy should be considered for further, future ECG monitoring and risk stratification with echocardiogram.


Circulation ◽  
2008 ◽  
Vol 118 (suppl_18) ◽  
Author(s):  
Hiroshi Sohara ◽  
Shutaro Satake ◽  
Hiroshi Takeda ◽  
Hideki Ueno ◽  
Toshimichi Oda

Atrial fibrillation (AF) is originated from mostly from pulmonary vein (PV) foci or non-PV foci in the posterior left atrium (PLA). The present study was designed to evaluate the usefulness of a radiofrequency HOT balloon catheter (RBC) for isolation of the PLA including all PVs en masse in the patients with AF. In a total of 96 patients (75 men and 21 women; mean age 64±8 years old) with drug-resistant paroxysmal (n=63) and persistent AF(n=33), PLA including all PVs were ablated and isolated using RBC. Dragging the balloon, contiguous lesions at the roof between the superior PVs were first created, then each antrum of all PVs were ablated, and finally, contiguous lesions at the PLA between the both inferior PVs were made, while we performed monitoring esophagus temperature and phrenic nerve pacing. Electro-anatomical bipolar voltage amplitude mapping (CARTO) of the LA-PVs was performed to determine the extent of this electrical isolation after all procedure. Successful isolation of the PLA including all PVs was achieved in all of 96 cases with elimination of all the PLA and PV potentials. The mean total procedure time 133 ± 31 minutes including 32±9 minutes fluoroscopy time. Recurrences of AF were diagnosed by Holter monitoring, mobile electrocardiogram. After first session, eighty- seven (59 paroxysmal, 28 persistent) of 96 patients were free from AF without anti-arrhythmic drugs and the remaining patients could maintain sinus rhythm with anti-arrhythmic drugs except two cases with LA flutter during 11.0±4.1 months follow-up. No major complications such as cerebral embolism, PV stenosis, or phrenic nerve palsy, and LA-esophageal fistula were observed. Complete isolation of the PLA including all PVs using a RBC, is useful for the treatment of both paroxysmal and persistent AF without severe complication.


Sign in / Sign up

Export Citation Format

Share Document