Comparison of the indoor air quality in an office operating with natural or mechanical ventilation using short-term intensive pollutant monitoring

2014 ◽  
Vol 24 (6) ◽  
pp. 777-787 ◽  
Author(s):  
James F. Montgomery ◽  
Stefan Storey ◽  
Karen Bartlett
2020 ◽  
pp. 1420326X2096076
Author(s):  
Pedro F. Pereira ◽  
Nuno M. M. Ramos

In Portugal, residential buildings commonly have their ventilation strategy changed after commissioning. This occurs due to the building managers' willingness to reduce shared costs with the electricity needed for fan operation. However, this option is not technically supported, and the effects of such a strategy on indoor air quality-related to human pollutants are yet to be quantified. CO2 was monitored in 15 bedrooms and air exchange rates were calculated for each room. The air exchange rate values ranged from 0.18 to 0.53 h−1 when mechanical extraction ventilation was off, and from 0.45 to 0.90 h−1 when mechanical extraction ventilation was on, which represents an average increase of 119%. With the current intermittent ventilation strategy, all rooms remain above 1500 ppm for a given percentage of time, and 12 rooms presenting CO2 concentrations above 2000 ppm. Simulations of theoretical CO2 concentrations, for a non-interrupted mechanical ventilation strategy show that no rooms would accumulate CO2 concentrations above 2000 ppm, and only 25% would present CO2 concentrations above 1500 ppm. Pearson correlations between the monitored CO2 and human and spatial factors identified two relevant parameters. Those parameters correspond to ratios between CO2 generation and floor area ([Formula: see text]), and airflow with CO2 generation ([Formula: see text]). The proposed ratios could be used as ways to optimise ventilation costs and indoor air quality.


2020 ◽  
pp. 1420326X2092474
Author(s):  
Tingxuan Deng ◽  
Xiong Shen ◽  
Xiaojie Cheng ◽  
Junjie Liu

Indoor air quality (IAQ) is a key factor that could affect the indoor environment and people's health. In this study, we report a comprehensive study on IAQ in 30 dwellings in the temperate zone in China. Thirty naturally ventilated dwellings were selected in the urban area of Kunming, which is the largest city in temperate zone in China. In four seasons, short-term measurement of formaldehyde and benzene, toluene, xylenes-volatile organic compounds and air infiltration rate were conducted in these dwellings. A long-term 1-year monitoring of temperature, relative humidity, fine particulate matter (PM2.5), carbon dioxide (CO2), window-opening behaviour and night-time air change rate (ACR) were conducted in 13 of these dwellings by remote sensors. Short-term measurements showed the mean formaldehyde concentration in summer (100.76 μg/m3), benzene concentration in winter (8.46 µg/m3), PM2.5 concentration (80.4 µg/m3) in spring of 2017 exceeded the Chinese standard, the US Office of Environmental Health Hazard Assessment value and the World Health Organization guidelines. The night-time ACR was the highest in summer (2.1 h−1) and the lowest in winter (1.6 h−1) in bedrooms of 13 long-term monitored dwellings due to seasonal time variation in window opening in bedrooms, which was mainly driven by CO2 concentration, indoor temperature and outdoor PM10 concentration.


2016 ◽  
Vol 2016 (1) ◽  
Author(s):  
Ming Kei Chung ◽  
Xiaoxing Cui* ◽  
Lin Fang ◽  
Jianbang Xiang ◽  
Feng Li ◽  
...  

2011 ◽  
Vol 6 (3) ◽  
pp. 168-180 ◽  
Author(s):  
Alireza Khaleghi ◽  
Karen Bartlett ◽  
Murray Hodgson

This paper discusses a pilot project involving the direct monitoring of ventilation, indoor-air quality and the acoustical conditions in selected nominally ‘green’ and non-‘green’ buildings located on a university campus. The objectives were to measure parameters quantifying these three aspects of indoor environmental quality, determine the relationships between them and the building-design concepts, and evaluate the implications of the results for ventilation-system design, especially in ‘green’ buildings. Measurements were made in rooms, with and without acoustical treatment, in buildings with natural ventilation or mechanical (displacement and/or mixed-flow) ventilation systems. Measurements were made of ventilation rates (air changes per hour), indoor air quality (respirable-fibre, total-VOC and ultrafine-particulate concentrations), and the acoustical conditions (noise levels and reverberation times). Correlations between the environmental results, the building concept, the ventilation concept and the building window status were explored. In rooms with natural ventilation, low-frequency noise and total sound-pressure levels were lower; however, the rooms had higher ultrafine-particulate counts and lower ventilation rates. Rooms with mechanical ventilation had higher low-frequency and total sound-pressure levels, higher ventilation rates and fibre concentrations, but lower concentrations of ultrafine particulates. It was concluded that, in general, mechanical ventilation can provide better indoor air-quality, but that HVAC noise is an issue if the system is not properly designed. In ‘green’ buildings, noise levels were acceptable when the windows were closed, but increasing the ventilation rate by opening the windows resulted in higher noise levels. The results suggest that the acceptability of environmental factors in buildings depends on the degree of compliance of the design and its implementation with standards and design guidelines (i.e. for ventilation, air quality, thermal comfort, etc.), whether the original design concept is ‘green’ or non-‘green’.


Sign in / Sign up

Export Citation Format

Share Document