scholarly journals FACTORS AFFECTING VENTILATION, INDOOR-AIR QUALITY AND ACOUSTICAL QUALITY IN ‘GREEN’ AND NON-‘GREEN’ BUILDINGS: A PILOT STUDY

2011 ◽  
Vol 6 (3) ◽  
pp. 168-180 ◽  
Author(s):  
Alireza Khaleghi ◽  
Karen Bartlett ◽  
Murray Hodgson

This paper discusses a pilot project involving the direct monitoring of ventilation, indoor-air quality and the acoustical conditions in selected nominally ‘green’ and non-‘green’ buildings located on a university campus. The objectives were to measure parameters quantifying these three aspects of indoor environmental quality, determine the relationships between them and the building-design concepts, and evaluate the implications of the results for ventilation-system design, especially in ‘green’ buildings. Measurements were made in rooms, with and without acoustical treatment, in buildings with natural ventilation or mechanical (displacement and/or mixed-flow) ventilation systems. Measurements were made of ventilation rates (air changes per hour), indoor air quality (respirable-fibre, total-VOC and ultrafine-particulate concentrations), and the acoustical conditions (noise levels and reverberation times). Correlations between the environmental results, the building concept, the ventilation concept and the building window status were explored. In rooms with natural ventilation, low-frequency noise and total sound-pressure levels were lower; however, the rooms had higher ultrafine-particulate counts and lower ventilation rates. Rooms with mechanical ventilation had higher low-frequency and total sound-pressure levels, higher ventilation rates and fibre concentrations, but lower concentrations of ultrafine particulates. It was concluded that, in general, mechanical ventilation can provide better indoor air-quality, but that HVAC noise is an issue if the system is not properly designed. In ‘green’ buildings, noise levels were acceptable when the windows were closed, but increasing the ventilation rate by opening the windows resulted in higher noise levels. The results suggest that the acceptability of environmental factors in buildings depends on the degree of compliance of the design and its implementation with standards and design guidelines (i.e. for ventilation, air quality, thermal comfort, etc.), whether the original design concept is ‘green’ or non-‘green’.

2021 ◽  
pp. 1420326X2110171
Author(s):  
Samuel Stamp ◽  
Esfand Burman ◽  
Clive Shrubsole ◽  
Lia Chatzidiakou ◽  
Dejan Mumovic ◽  
...  

The indoor air quality (IAQ) of five low-energy London apartments has been assessed through the measurement of 16 key pollutants, using continuous and diffusive methods across heating and non-heating seasons. This case study approach aimed to assess the presence of pollutants within low-energy apartments and to better understand the role of ventilation and seasonal variations in indoor air quality. The results indicate strong seasonal variations, driven by increased natural ventilation rates over the summer monitoring period. A combined metric for indoor and outdoor pollutants ( Itot) suggests that the IAQ in the winter ( Itot = 17.7) is more than twice as bad as that seen in the summer ( Itot = 8.6). Formaldehyde concentrations were lower in the non-heating season, indicating increased ventilation rates more than offset increased off-gassing, in contrast to findings in other studies. However, increased summertime ventilation rates were observed to increase the proportion of outdoor pollutants entering the internal environment. This resulted in higher indoor concentrations of NO2 in the summer than the winter, despite significant reductions in outdoor concentrations. These results demonstrate the impact of ventilation practices upon IAQ, the influence of occupant actions and the complex relationship ventilation rates play in balancing indoor and outdoor sources of air pollution.


Energies ◽  
2021 ◽  
Vol 15 (1) ◽  
pp. 220
Author(s):  
Yeo-Kyung Lee ◽  
Young Il Kim

Owing to the recent increase in the number of warning reports and alerts on the dangers of fine dusts, there has been an increasing concern over fine dusts among citizens. In spaces with poor ventilation, the occupants are forced to open the window to initiate natural ventilation via the direct introduction of the outside air; however, this may pose a serious challenge if the external fine-dust concentration is high. The lack of natural ventilation increases the indoor carbon dioxide (CO2) concentration, thus necessitating the installation of mechanical ventilation systems. This study analyzed the frequency of the application of mechanical ventilation systems in the Multi-purpose activity space of elementary schools, which are spaces where children require a higher indoor air quality than adults owing to the rapid increase in the CO2 concentration of the Multi-purpose activity space during activities. In addition, the architectural and equipment factors of the Multi-purpose activity spaces of nine elementary schools were characterized. The results revealed that five out of the nine elementary schools installed mechanical ventilation systems, whereas the remaining four schools installed jet air turnover systems. The indoor air quality of the Multi-purpose activity space of D elementary school, which had the minimum facility volume among the schools investigated in this study (564.2 m3), with up to 32 participants for each activity, was investigated. The results revealed that the ultrafine-dust (PM2.5) concentration of the facility was as high as 4.75 µg/m3 at a height of 1.2 m, and the CO2 concentration was as high as 3183 ppm. The results of the analysis of three elementary schools with different volumes were compared and analyzed using CONTAM simulation. This study determined the required volume per occupant and the optimum number of occupants for a given volume and presented guidelines for the optimum number of occupants, activities, and volume to reduce the high concentration of pollutants in the analyzed Multi-purpose activity space. The guideline proposed in this study is aimed at maintaining the CO2 concentration of the Multi-purpose activity space below 1000 ppm, as prescribed by the Indoor Air Quality Control in Public-Use Facilities, Etc. Act in South Korea.


Sensors ◽  
2021 ◽  
Vol 21 (18) ◽  
pp. 6122
Author(s):  
María L. de la Hoz-Torres ◽  
Antonio J. Aguilar ◽  
Diego P. Ruiz ◽  
María Dolores Martínez-Aires

Indoor environmental conditions can significantly affect occupants’ health and comfort. These conditions are especially important in educational buildings, where students, teachers and staff spend long periods of the day and are vulnerable to these factors. Recently, indoor air quality has been a focus of attention to ensure that disease transmission in these spaces is minimised. In order to increase the knowledge in this field, experimental tests have been carried out to characterise the impact of natural ventilation strategies on indoor air quality and the acoustic environment. This study has evaluated three ventilation scenarios in four different classrooms in buildings of the University of Granada, considering different window and door opening configurations. Ventilation rates were estimated using the CO2 Decay Method, and background noise recordings were made in each classroom for acoustic tests. Results show that specific natural ventilation strategies have a relevant impact that is worth considering on the background noise in indoor spaces. In this sense ventilation rates provided by the different configurations varied between 3.7 and 39.8 air changes per hour (ACH) and the acoustic tests show a background noise ranging from 43 to 54 dBA in these scenarios. Consequently, managers and teachers should take into account not only the ACH, but also other collateral impacts on the indoor environmental conditions such as the thermal comfort or the acoustic environment.


Author(s):  
Farhang Tahmasebi ◽  
Yan Wang ◽  
Elizabeth Cooper ◽  
Daniel Godoy Shimizu ◽  
Samuel Stamp ◽  
...  

The Covid-19 outbreak has resulted in new patterns of home occupancy, the implications of which for indoor air quality (IAQ) and energy use are not well-known. In this context, the present study investigates 8 flats in London to uncover if during a lockdown, (a) IAQ in the monitored flats deteriorated, (b) the patterns of window operation by occupants changed, and (c) more effective ventilation patterns could enhance IAQ without significant increases in heating energy demand. To this end, one-year’s worth of monitored data on indoor and outdoor environment along with occupant use of windows has been used to analyse the impact of lockdown on IAQ and infer probabilistic models of window operation behaviour. Moreover, using on-site CO2 data, monitored occupancy and operation of windows, the team has calibrated a thermal performance model of one of the flats to investigate the implications of alternative ventilation strategies. The results suggest that despite the extended occupancy during lockdown, occupants relied less on natural ventilation, which led to an increase of median CO2 concentration by up to 300 ppm. However, simple natural ventilation patterns or use of mechanical ventilation with heat recovery proves to be very effective to maintain acceptable IAQ. Practical application: This study provides evidence on the deterioration of indoor air quality resulting from homeworking during imposed lockdowns. It also tests and recommends specific ventilation strategies to maintain acceptable indoor air quality at home despite the extended occupancy hours.


2020 ◽  
pp. 1420326X2096076
Author(s):  
Pedro F. Pereira ◽  
Nuno M. M. Ramos

In Portugal, residential buildings commonly have their ventilation strategy changed after commissioning. This occurs due to the building managers' willingness to reduce shared costs with the electricity needed for fan operation. However, this option is not technically supported, and the effects of such a strategy on indoor air quality-related to human pollutants are yet to be quantified. CO2 was monitored in 15 bedrooms and air exchange rates were calculated for each room. The air exchange rate values ranged from 0.18 to 0.53 h−1 when mechanical extraction ventilation was off, and from 0.45 to 0.90 h−1 when mechanical extraction ventilation was on, which represents an average increase of 119%. With the current intermittent ventilation strategy, all rooms remain above 1500 ppm for a given percentage of time, and 12 rooms presenting CO2 concentrations above 2000 ppm. Simulations of theoretical CO2 concentrations, for a non-interrupted mechanical ventilation strategy show that no rooms would accumulate CO2 concentrations above 2000 ppm, and only 25% would present CO2 concentrations above 1500 ppm. Pearson correlations between the monitored CO2 and human and spatial factors identified two relevant parameters. Those parameters correspond to ratios between CO2 generation and floor area ([Formula: see text]), and airflow with CO2 generation ([Formula: see text]). The proposed ratios could be used as ways to optimise ventilation costs and indoor air quality.