A novel and simple technique for correcting localised rotations in the early alignment stage

2020 ◽  
Vol 47 (4) ◽  
pp. 338-344
Author(s):  
Aslam Alkadhimi

Correcting severe tooth rotations can be challenging. There are many ways to de-rotate teeth with fixed or removable appliances. Mechanically, the best and most effective way is one that produces a two-force couple system to rotate a tooth around its centre of rotation (longitudinal axis). The aim of this article was to introduce a simple and efficient technique using a closed coil to correct localised tooth rotations in the early alignment stage, utilising a simple two-force couple system. Furthermore, some of the biomechanical principles concerning de-rotation will be revisited.

Author(s):  
E. L. Vigil ◽  
E. F. Erbe

In cotton seeds the radicle has 12% moisture content which makes it possible to prepare freeze-fracture replicas without fixation or cryoprotection. For this study we have examined replicas of unfixed radicle tissue fractured at room temperature to obtain data on organelle and membrane structure.Excised radicles from seeds of cotton (Gossyplum hirsutum L. M-8) were fractured at room temperature along the longitudinal axis. The fracture was initiated by spliting the basal end of the excised radicle with a razor. This procedure produced a fracture through the tissue along an unknown fracture plane. The warm fractured radicle halves were placed on a thin film of 100% glycerol on a flat brass cap with fracture surface up. The cap was rapidly plunged into liquid nitrogen and transferred to a freeze- etch unit. The sample was etched for 3 min at -95°C to remove any condensed water vapor and then cooled to -150°C for platinum/carbon evaporation.


Author(s):  
C. W. Price ◽  
E. F. Lindsey ◽  
R. M. Franks ◽  
M. A. Lane

Diamond-point turning is an efficient technique for machining low-density polystyrene foam, and the surface finish can be substantially improved by grinding. However, both diamond-point turning and grinding tend to tear and fracture cell walls and leave asperities formed by agglomerations of fragmented cell walls. Vibratoming is proving to be an excellent technique to form planar surfaces in polystyrene, and the machining characteristics of vibratoming and diamond-point turning are compared.Our work has demonstrated that proper evaluation of surface structures in low density polystyrene foam requires stereoscopic examinations; tilts of + and − 3 1/2 degrees were used for the stereo pairs. Coating does not seriously distort low-density polystyrene foam. Therefore, the specimens were gold-palladium coated and examined in a Hitachi S-800 FESEM at 5 kV.


Author(s):  
Vladimir Popenko ◽  
Natalya Cherny ◽  
Maria Yakovleva

Highly polyploid somatic nucleus (macronucleus) of ciliate Bursaria truncatella under goes severe changes in morphology during cell division. At first, macronucleus (Ma) condences, diminishes in size and turns perpendicular to longitudinal axis of the cell. After short time, Ma turns again, elongates and only afterwards the process of division itself occurs. The biological meaning of these phenomena is not clear.Localization of RNA in the cells was performed on sections of ciliates B. truncatella, embedded in “Lowicryl K4M” at various stages: (1) before cell division (Figs. 2,3); (11) at the stage of macronucleus condensation; (111) during elongation of Ma (Fig.4); (1111) in young cells (0-5min. after division). For cytochemical labelling we used RNaseAcolloidal gold complexes (RNase-Au), which are known to bind to RNA containing cell ularstructures with high specificity. The influence of different parameters on the reliability and reproducibility of labelling was studied. In addition to the factors, discussed elsewhere, we found that the balance of mono- and bivalent cations is of great significance.


1962 ◽  
Vol 42 (2) ◽  
pp. 157-159 ◽  
Author(s):  
Eugene J. Gangarosa ◽  
William R. Beisel

1998 ◽  
Vol 21 (4) ◽  
pp. 109-114
Author(s):  
C Albarrán ◽  
R Montés-Micó ◽  
A M Pons ◽  
A Gené ◽  
A Lorente

2020 ◽  
Vol 19 (2) ◽  
pp. 64-68
Author(s):  
Mrinmoy Biswas ◽  
Sudip Das Gupta ◽  
Mohammed Mizanur Rahman ◽  
Sharif Mohammad Wasimuddin

Objective: To assess the success of BMG urethroplasty in long segment anterior urethral stricture. Method: From January 2014 to December 2015, twenty male patients with long anterior segment urethral stricture were managed by BMG urethroplasty. After voiding trial they were followed up at 3 month with Uroflowmetry, RGU & MCU and PVR measurement by USG. Patients were further followed up with Uroflowmetry and PVR at 6 months interval.Successful outcome was defined as normal voiding with a maximum flow rate >15ml /sec and PVR<50 ml with consideration of maximum one attempt of OIU after catheter removal. Results: Mean stricture length was 5.2 cm (range 3-9 cm) and mean follow-up was 15.55 months (range 6-23 months). Only two patients developed stricture at proximal anastomotic site during follow-up. One of them voided normally after single attempt of OIU. Other one required second attempt of OIU and was considered as failure (5%). Conclusion: BMG urethroplasty is a simple technique with good surgical outcome. Bangladesh Journal of Urology, Vol. 19, No. 2, July 2016 p.64-68


2020 ◽  
Vol 141 ◽  
pp. 39-46
Author(s):  
MD Dorjievna Batueva ◽  
X Pan ◽  
J Zhang ◽  
X Liu ◽  
W Wei ◽  
...  

In the present study, we provide supplementary data for Myxidium cf. rhodei Léger, 1905 based on morphological, histological and molecular characterization. M. cf. rhodei was observed in the kidneys of 918 out of 942 (97%) roach Rutilus rutilus (Linnaeus, 1758). Myxospores of M. cf. rhodei were fusiform with pointed ends, measuring 12.7 ± 0.1 SD (11.8-13.4) µm in length and 4.6 ± 0.1 (3.8-5.4) µm in width. Two similar pear-shaped polar capsules were positioned at either ends of the longitudinal axis of the myxospore: each of these capsules measured 4.0 ± 0.1 (3.1-4.7) µm in length and 2.8 ± 0.1 (2.0-4.0) µm in width. Polar filaments were coiled into 4 to 5 turns. Approximately 18-20 longitudinal straight ridges were observed on the myxospore surface. The suture line was straight and distinctive, running near the middle of the valves. Histologically, the plasmodia of the present species were found in the Bowman’s capsules, and rarely in the interstitium of the host. Phylogenetic analysis revealed that M. cf. rhodei was sister to M. anatidum in the Myxidium clade including most Myxidium species from freshwater hosts.


Sign in / Sign up

Export Citation Format

Share Document