scholarly journals Diabetes mellitus remission in three cats with hypersomatotropism after cabergoline treatment

2021 ◽  
Vol 7 (1) ◽  
pp. 205511692110189
Author(s):  
Diego D Miceli ◽  
Patricia N Vidal ◽  
Gustavo A Pompili ◽  
Víctor A Castillo ◽  
Elber A Soler Arias ◽  
...  

Case summary Three diabetic cats presented with polyuria, polydipsia, polyphagia and poor glycemic control. Cat 1 displayed prognathia inferior and had a body condition score (BCS) of 4/5; cat 2 had a BCS of 5/5; and cat 3 had broad facial features. Serum insulin-like growth factor 1 concentrations were compatible with hypersomatotropism in cat 1 and cat 2 (>1500 ng/ml and 1200 ng/ml, respectively) and just below the cut-off of 1000 ng/ml (947 ng/ml) in cat 3; in this last cat diagnosis was further supported by the presence of pituitary enlargement on MRI. Oral cabergoline (10 μg/kg q48h) was initiated. Insulin requirements progressively reduced, as evidenced by daily blood glucose monitoring and weekly blood glucose curves. Diabetic remission occurred in all three cats between the second and third months of cabergoline treatment. At the time of writing, remission has persisted thus far (cat 1: 23 months; cat 2: 14 months; cat 3: 38 months). Relevance and novel information To our knowledge, these are the first reported cases of diabetic remission in cats with hypersomatotropism after cabergoline treatment, despite previous reports of this being an ineffective treatment. Further work is indicated to determine why some cats do, and others do not, respond to this treatment.

Diabetes ◽  
2019 ◽  
Vol 68 (Supplement 1) ◽  
pp. 941-P
Author(s):  
LEI ZHANG ◽  
YAN GU ◽  
YUXIU YANG ◽  
NA WANG ◽  
WEIGUO GAO ◽  
...  

2021 ◽  
pp. 193229682110071
Author(s):  
Loukia Spanou ◽  
Konstantinos Makris

In this issue of Journal of Diabetes Science and Technology, Baumstark et al. evaluated the analytical performance of a bench-top laboratory glucose analyzer (SUPER-GL) intended for replacement for the YSI2300-STAT analyzer, that served for several decades as a comparator method in clinical and analytical studies of blood glucose monitoring systems (BGMS). The authors concluded that the SUPER-GL’s overall performance is comparable to that of YSI2300-STAT, and has the potential to be a candidate comparator analyzer. However, the question is if we need to recommend as a “comparator method,” a specific device, that measure glucose using the same analytical method with most BGMS. In this analysis we present our point of view hoping to generate a discussion on the necessity for such a replacement.


Author(s):  
Li-Nong Ji ◽  
Li-Xin Guo ◽  
Li-Bin Liu

AbstractBlood glucose self-monitoring by individuals with diabetes is essential in controlling blood glucose levels. The International Organization for Standardization (ISO) introduced new standards for blood glucose monitoring systems (BGMS) in 2013 (ISO 15197: 2013). The CONTOUR PLUSThis study evaluated the accuracy and precision of CONTOUR PLUS BGMS in quantitative glucose testing of capillary and venous whole blood samples obtained from 363 patients at three different hospitals.Results of fingertip and venous blood glucose measurements by the CONTOUR PLUS system were compared with laboratory reference values to determine accuracy. Accuracy was 98.1% (96.06%–99.22%) for fingertip blood tests and 98.1% (96.02%–99.21%) for venous blood tests. Precision was evaluated across a wide range of blood glucose values (5.1–17.2 mmol/L), testing three blood samples repeatedly 15 times with the CONTOUR PLUS blood glucose meter using test strips from three lots. All within-lot results met ISO criteria (i.e., SD<0.42 mmol/L for blood glucose concentration <5.55 mmol/L; CV<7.5% for blood glucose concentration ≥5.55 mmol/L). Between-lot variations were 1.5% for low blood glucose concentration, 2.4% for normal and 3.4% for high.Accuracy of both fingertip and venous blood glucose measurements by the CONTOUR PLUS system was >95%, confirming that the system meets ISO 15197: 2013 requirements.


2012 ◽  
Vol 6 (5) ◽  
pp. 1060-1075 ◽  
Author(s):  
Guido Freckmann ◽  
Christina Schmid ◽  
Annette Baumstark ◽  
Stefan Pleus ◽  
Manuela Link ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document