scholarly journals Reliability of three-dimensional kinematic gait data in adults with spinal cord injury

2017 ◽  
Vol 4 ◽  
pp. 205566831772999 ◽  
Author(s):  
Pia Wedege ◽  
Kathrin Steffen ◽  
Vegard Strøm ◽  
Arve Isak Opheim

Objectives Three-dimensional gait analysis has been recommended as part of standardized gait assessment in people with spinal cord injury. The aim was to investigate inter- and intra-session reliabilities of gait kinematics in people with spinal cord injury. Methods Fifteen adults with spinal cord injury performed two test sessions on separate days. Six infrared cameras, 16 reflective markers and the Plug-in gait model were used. For each subject, five gait trials from both sessions were included. The Gait Profile Score and the Gait Variable Score were used as kinematic outcome measures. Reliability was assessed with intraclass correlation coefficient, standard error of measurement, minimal detectable change, and Bland–Altman plots. Results Inter-session intraclass correlation coefficient for all variables was >0.82 and standard error of measurement <1.8°, except for hip rotation. Intra-session reliability was found to be high (≥0.78) and slightly better than that for inter-session. Minimal detectable change for all variables was <4.7°, except for hip rotation. Conclusions The high inter- and intra-session reliabilities indicate small intrinsic variation of gait. Thus, three-dimensional gait analysis seems to be a reliable tool to evaluate kinematic gait in adults with spinal cord injury, but caution is warranted especially for hip rotation evaluation.

10.2196/26443 ◽  
2021 ◽  
Vol 9 (2) ◽  
pp. e26443
Author(s):  
Ariane Do Khac ◽  
Claire Jourdan ◽  
Sylvain Fazilleau ◽  
Claire Palayer ◽  
Isabelle Laffont ◽  
...  

Background Clinical evaluation of a pressure ulcer is based on quantitative and qualitative evaluation. In clinical practice, acetate tracing is the standard technique used to measure wound surface area; however, it is difficult to use in daily practice (because of material availability, data storage issues, and time needed to calculate the surface area). Planimetry techniques developed with mobile health (mHealth) apps can be used to overcome these difficulties. Objective The goal of this study was to evaluate the metrological properties of a free-access mHealth app, called imitoMeasure, to assess pressure ulcers. Methods This was a noninterventional, validation study. We included patients with spinal cord injury presenting with a pressure ulcer, regardless of its stage or location. We performed wound measurements with a ruler, and we performed acetate tracing using a transparent dressing with a wound measurement grid. Wound evaluation via the mHealth app was conducted twice by the main investigator and also by a coinvestigator to determine validity, intrarater reproducibility, and interrater reproducibility. Bland-Altman plots and intraclass correlation coefficients were used to compute the minimal detectable change percentage. Results Overall, 61 different pressure ulcers were included. The validity, intrarater reproducibility, and interrater reproducibility of the mHealth app vs acetate tracing (considered the method of reference) were good, with intraclass correlation coefficients of 0.97 (95% CI 0.93-0.99), 0.99 (95% CI 0.98-0.99), and 0.98 (95% CI 0.96-0.99), respectively, and minimal detectable change percentages between 17% and 35%. Conclusions The imitoMeasure app had good validity and reproducibility. It could be an alternative to standard wound assessment methods. Further studies on larger and more diverse wounds are needed. Trial Registration ClinicalTrials.gov NCT04402398; http://clinicaltrials.gov/ct2/show/NCT04402398


2018 ◽  
Vol 38 (02) ◽  
pp. 115-123
Author(s):  
Preeti Baghel ◽  
Shefali Walia ◽  
Majumi M Noohu

Background: Transfers are very important in functional activities of subjects with spinal cord injury (SCI). The transfer assessment instrument (TAI) was the first tool to standardize the assessment of transfer technique. Objective: The purpose of this study was to establish the reliability and validity of TAI 3.0 in people with SCI in early rehabilitation phase. Methods: Thirty subjects with acute traumatic SCI were recruited from a tertiary care center for SCI management. Four raters assessed the quality of transfer using TAI 3.0 and a fifth rater used global assessment of transfer scale (VAS). TAI 3.0’s intraclass correlation coefficient (ICC) for intrarater and interrater reliability, standard error of measurement (SEM), minimal detectable change (MDC), limits of agreement and concurrent validity was determined. Results: The intrarater ICC was 0.93 to 0.98 and interrater ICC was 0.99, indicating high levels of reliability. The SEMs among the raters for TAI 3.0 total was from 0.23 to 0.28. The MDC among the raters TAI 3.0 total was from 0.54 to 0.86. Correlation for different raters between the TAI 3.0 and VAS ranged between 0.88 and 0.90. Conclusion: TAI 3.0 is a reliable and valid tool to assess the transfer skill in individuals with SCI in early rehabilitation phase.


2014 ◽  
Vol 94 (2) ◽  
pp. 240-250 ◽  
Author(s):  
Kristin E. Musselman ◽  
Jaynie F. Yang

Background The Spinal Cord Injury Functional Ambulation Profile (SCI-FAP) is a valid, reliable measure of walking skill (eg, walking while negotiating obstacles, doors, and stairs). Objective The responsiveness of the SCI-FAP was assessed at least 7 months after spinal cord injury (SCI) and compared with that of the 10-Meter Walk Test (10MWT) and the Six-Minute Walk Test (6MWT). Design A secondary analysis of data collected during a randomized, single-blind, crossover trial was performed. Methods Participants had incomplete SCI and could walk at least 5 m without manual assistance. After 3 or 4 baseline assessments, participants completed 2 months of precision training (stepping over obstacles and onto targets on the ground) and 2 months of endurance training (treadmill training with body weight support, if needed). Walking function was assessed with the SCI-FAP, 10MWT, and 6MWT. Internal responsiveness was evaluated through change scores and standardized response means (SRMs). External responsiveness was gauged by correlating change scores on the SCI-FAP, 10MWT, and 6MWT. The minimal detectable change was calculated from the standard error of measurement from the baseline assessments. Results The SCI-FAP scores improved with both interventions. The magnitude of change was greater for participants whose pretraining self-selected speed was less than 0.5 m/s. The SCI-FAP had moderate SRMs. The 10MWT (fastest speed) and 6MWT had the largest SRMs after precision training and endurance training, respectively. The minimal detectable change in the SCI-FAP was 96 points. Limitations The convenience sample was small and all participants could ambulate independently (with devices); therefore, the generalizability of the findings is limited. Conclusions The SCI-FAP was responsive to changes in walking ability in participants who had incomplete SCI and walked at slow speeds, but overall the 10MWT and 6MWT were more responsive.


2022 ◽  
Author(s):  
Jianwu Dai ◽  
Yunlong Zou ◽  
Yanyun Yin ◽  
Zhifeng Xiao ◽  
Yannan Zhao ◽  
...  

Numerous studies have indicated that microgravity induces various changes in the cellular functions of neural stem cells (NSCs), and the use of microgravity to culture tissue engineering seed cells for...


2020 ◽  
pp. 026921552096670
Author(s):  
Huayi Xing ◽  
Nan Liu ◽  
Fin Biering-Sørensen

Objective: To investigate the validity and reliability of a Chinese version of Spinal Cord Independence Measure III (SCIM III) in individuals with spinal cord injury. Design: Study on psychometric properties. Setting: An inpatient rehabilitation facility in China. Subjects: 102 participants with spinal cord injury. Mean (SD) age was 48.8 (15.6) years; tetraplegia/paraplegia ratio was 50/52; median time post injury was 2 months. Intervention: SCIM III was translated into Chinese. Chinese versions of Barthel Index and SCIM III were filled out for each participant by Rater 1. SCIM III was then administered by Rater 2 after 24 hours ( n = 67) and 7 days ( n = 65). Main Measures: Validity, inter-rater/test-retest reliability, and internal consistency of the Chinese version of SCIM III. Results: The total scores between the two raters were similar (mean ± SD: 33.8 ± 25.8 vs 33.8 ± 25.5, P = 0.95). Total agreement between the raters in each item was >80%, with both Pearson and intraclass correlation coefficients >0.97 ( P < 0.01) for each subscale and total score. The Pearson correlation coefficients of the two independent assessments performed by Rater 2 were also >0.97 ( P < 0.01) for each subscale and the total score. Cronbach α was >0.7 for each subscale and the total score for both raters. High consistency was found between Barthel Index and SCIM III total scores (Pearson correlation coefficient = 0.88, P < 0.01). Conclusion: The Chinese version of SCIM III is valid and reliable for the functional assessment of patients with SCI.


Sign in / Sign up

Export Citation Format

Share Document