scholarly journals Spine Surgery Supported by Augmented Reality

2020 ◽  
Vol 10 (2_suppl) ◽  
pp. 41S-55S
Author(s):  
Barbara Carl ◽  
Miriam Bopp ◽  
Benjamin Saß ◽  
Mirza Pojskic ◽  
Benjamin Voellger ◽  
...  

Study Design: A prospective, case-based, observational study. Objectives: To investigate how microscope-based augmented reality (AR) support can be utilized in various types of spine surgery. Methods: In 42 spinal procedures (12 intra- and 8 extradural tumors, 7 other intradural lesions, 11 degenerative cases, 2 infections, and 2 deformities) AR was implemented using operating microscope head-up displays (HUDs). Intraoperative low-dose computed tomography was used for automatic registration. Nonlinear image registration was applied to integrate multimodality preoperative images. Target and risk structures displayed by AR were defined in preoperative images by automatic anatomical mapping and additional manual segmentation. Results: AR could be successfully applied in all 42 cases. Low-dose protocols ensured a low radiation exposure for registration scanning (effective dose cervical 0.29 ± 0.17 mSv, thoracic 3.40 ± 2.38 mSv, lumbar 3.05 ± 0.89 mSv). A low registration error (0.87 ± 0.28 mm) resulted in a reliable AR representation with a close matching of visualized objects and reality, distinctly supporting anatomical orientation in the surgical field. Flexible AR visualization applying either the microscope HUD or video superimposition, including the ability to selectively activate objects of interest, as well as different display modes allowed a smooth integration in the surgical workflow, without disturbing the actual procedure. On average, 7.1 ± 4.6 objects were displayed visualizing target and risk structures reliably. Conclusions: Microscope-based AR can be applied successfully to various kinds of spinal procedures. AR improves anatomical orientation in the surgical field supporting the surgeon, as well as it offers a potential tool for education.

2019 ◽  
Vol 47 (6) ◽  
pp. E11 ◽  
Author(s):  
Barbara Carl ◽  
Miriam Bopp ◽  
Benjamin Saß ◽  
Mirza Pojskic ◽  
Marko Gjorgjevski ◽  
...  

OBJECTIVELow registration errors are an important prerequisite for reliable navigation, independent of its use in cranial or spinal surgery. Regardless of whether navigation is used for trajectory alignment in biopsy or implant procedures, or for sophisticated augmented reality applications, all depend on a correct registration of patient space and image space. In contrast to fiducial, landmark, or surface matching–based registration, the application of intraoperative imaging allows user-independent automatic patient registration, which is less error prone. The authors’ aim in this paper was to give an overview of their experience using intraoperative CT (iCT) scanning for automatic registration with a focus on registration accuracy and radiation exposure.METHODSA total of 645 patients underwent iCT scanning with a 32-slice movable CT scanner in combination with navigation for trajectory alignment in biopsy and implantation procedures (n = 222) and for augmented reality (n = 437) in cranial and spine procedures (347 craniotomies and 42 transsphenoidal, 56 frameless stereotactic, 59 frame-based stereotactic, and 141 spinal procedures). The target registration error was measured using skin fiducials that were not part of the registration procedure. The effective dose was calculated by multiplying the dose length product with conversion factors.RESULTSAmong all 1281 iCT scans obtained, 1172 were used for automatic patient registration (645 initial registration scans and 527 repeat iCT scans). The overall mean target registration error was 0.86 ± 0.38 mm (± SD) (craniotomy, 0.88 ± 0.39 mm; transsphenoidal, 0.92 ± 0.39 mm; frameless, 0.74 ± 0.39 mm; frame-based, 0.84 ± 0.34 mm; and spinal, 0.80 ± 0.28 mm). Compared with standard diagnostic scans, a distinct reduction of the effective dose could be achieved using low-dose protocols for the initial registration scan with mean effective doses of 0.06 ± 0.04 mSv for cranial, 0.50 ± 0.09 mSv for cervical, 4.12 ± 2.13 mSv for thoracic, and 3.37 ± 0.93 mSv for lumbar scans without impeding registration accuracy.CONCLUSIONSReliable automatic patient registration can be achieved using iCT scanning. Low-dose protocols ensured a low radiation exposure for the patient. Low-dose scanning had no negative effect on navigation accuracy.


2020 ◽  
Vol 24 (1) ◽  
pp. 39-47
Author(s):  
A. P. Gonchar ◽  
V. A. Gombolevskij ◽  
A. B. Elizarov ◽  
N. S. Kulberg ◽  
V. G. Klyashtorny ◽  
...  

2019 ◽  
Vol 31 (1) ◽  
pp. 139-146 ◽  
Author(s):  
Camilo A. Molina ◽  
Nicholas Theodore ◽  
A. Karim Ahmed ◽  
Erick M. Westbroek ◽  
Yigal Mirovsky ◽  
...  

OBJECTIVEAugmented reality (AR) is a novel technology that has the potential to increase the technical feasibility, accuracy, and safety of conventional manual and robotic computer-navigated pedicle insertion methods. Visual data are directly projected to the operator’s retina and overlaid onto the surgical field, thereby removing the requirement to shift attention to a remote display. The objective of this study was to assess the comparative accuracy of AR-assisted pedicle screw insertion in comparison to conventional pedicle screw insertion methods.METHODSFive cadaveric male torsos were instrumented bilaterally from T6 to L5 for a total of 120 inserted pedicle screws. Postprocedural CT scans were obtained, and screw insertion accuracy was graded by 2 independent neuroradiologists using both the Gertzbein scale (GS) and a combination of that scale and the Heary classification, referred to in this paper as the Heary-Gertzbein scale (HGS). Non-inferiority analysis was performed, comparing the accuracy to freehand, manual computer-navigated, and robotics-assisted computer-navigated insertion accuracy rates reported in the literature. User experience analysis was conducted via a user experience questionnaire filled out by operators after the procedures.RESULTSThe overall screw placement accuracy achieved with the AR system was 96.7% based on the HGS and 94.6% based on the GS. Insertion accuracy was non-inferior to accuracy reported for manual computer-navigated pedicle insertion based on both the GS and the HGS scores. When compared to accuracy reported for robotics-assisted computer-navigated insertion, accuracy achieved with the AR system was found to be non-inferior when assessed with the GS, but superior when assessed with the HGS. Last, accuracy results achieved with the AR system were found to be superior to results obtained with freehand insertion based on both the HGS and the GS scores. Accuracy results were not found to be inferior in any comparison. User experience analysis yielded “excellent” usability classification.CONCLUSIONSAR-assisted pedicle screw insertion is a technically feasible and accurate insertion method.


2015 ◽  
pp. 12-19
Author(s):  
Thi Ngoc Ha Hoang ◽  
Trong Khoan Le

Background: A pulmonary nodule is defined as a rounded or irregular opacity, well or poorly defined, measuring up to 3 cm in diameter. Early detection the malignancy of nodules has a significant role in decreasing the mortality, increasing the survival time and consider as early diagnosis lung cancer. The main risk factors are those of current or former smokers, aged 55 to 74 years with a smoking history of at least 1 pack-day. Low dose CT: screening individuals with high risk of lung cancer by low dose CT scans could reduce lung cancer mortality by 20 percent compared to chest X-ray. Radiation dose has to maximum reduced but respect the rule of ALARA (As Low as Resonably Archivable). LungRADS 2014: Classification of American College of Radiology, LungRADS, is a newly application but showed many advantages in comparison with others classification such as increasing positive predict value (PPV), no result of false negative and cost effectiveness. Key words: LungRADS, screening lung nodule, low dose CT, lung cancer


2019 ◽  
Vol 65 (2) ◽  
pp. 224-233
Author(s):  
Sergey Morozov ◽  
Viktor Gombolevskiy ◽  
Anton Vladzimirskiy ◽  
Albina Laypan ◽  
Pavel Kononets ◽  
...  

Study aim. To justify selective lung cancer screening via low-dose computed tomography and evaluate its effectiveness. Materials and methods. In 2017 we have concluded the baseline stage of “Lowdose computed tomography in Moscow for lung cancer screening (LDCT-MLCS)” trial. The trial included 10 outpatient clinics with 64-detector CT units (Toshiba Aquilion 64 and Toshiba CLX). Special low-dose protocols have been developed for each unit with maximum effective dose of 1 mSv (in accordance with the requirements of paragraph 2.2.1, Sanitary Regulations 2.6.1.1192-03). The study involved 5,310 patients (53% men, 47% women) aged 18-92 years (mean age 62 years). Diagnosis verification was carried out in the specialized medical organizations via consultations, additional instrumental, laboratory as well as pathohistological studies. The results were then entered into the “National Cancer Registry”. Results. 5310 patients (53% men, 47% women) aged 18 to 92 years (an average of 62 years) participated in the LDCT-MLCS. The final cohort was comprised of 4762 (89.6%) patients. We have detected 291 (6.1%) Lung-RADS 3 lesions, 228 (4.8%) Lung- RADS 4A lesions and 196 (4.1%) Lung-RADS 4B/4X lesions. All 4B and 4X lesions were routed in accordance with the project's methodology and legislative documents. Malignant neoplasms were verified in 84 cases (1.76% of the cohort). Stage I-II lung cancer was actively detected in 40.3% of these individuals. For the first time in the Russian Federation we have calculated the number needed to screen (NNS) to identify one lung cancer (NNS=57) and to detect one Stage I lung cancer (NNS=207). Conclusions. Based on the global experience and our own practices, we argue that selective LDCT is the most systematic solution to the problem of early-stage lung cancer screening.


2021 ◽  
Vol 151 ◽  
pp. 290
Author(s):  
Alexander J. Schupper ◽  
Jeremy Steinberger ◽  
Yakov Gologorsky

Dose-Response ◽  
2020 ◽  
Vol 18 (4) ◽  
pp. 155932582097313
Author(s):  
Dario Baldi ◽  
Liberatore Tramontano ◽  
Vincenzo Alfano ◽  
Bruna Punzo ◽  
Carlo Cavaliere ◽  
...  

For decades, the main imaging tool for multiple myeloma (MM) patient’s management has been the conventional skeleton survey. In 2014 international myeloma working group defined the advantages of the whole-body low dose computed tomography (WBLDCT) as a gold standard, among imaging modalities, for bone disease assessment and subsequently implemented this technique in the MM diagnostic workflow. The aim of this study is to investigate, in a group of 30 patients with a new diagnosis of MM, the radiation dose (CT dose index, dose-length product, effective dose), the subjective image quality score and osseous/extra-osseous findings rate with a modified WBLDCT protocol. Spectral shaping and third-generation dual-source multidetector CT scanner was used for the assessment of osteolytic lesions due to MM, and the dose exposure was compared with the literature findings reported until 2020. Mean radiation dose parameters were reported as follows: CT dose index 0.3 ± 0.1 mGy, Dose-Length Product 52.0 ± 22.5 mGy*cm, effective dose 0.44 ± 0.19 mSv. Subjective image quality was good/excellent in all subjects. 11/30 patients showed osteolytic lesions, with a percentage of extra-osseous findings detected in 9/30 patients. Our data confirmed the advantages of WBLDCT in the diagnosis of patients with MM, reporting an effective dose for our protocol as the lowest among previous literature findings.


Sign in / Sign up

Export Citation Format

Share Document