Value of sonography in assessing parametrial endometriotic involvement: Preliminary results

Author(s):  
Marc Bazot ◽  
Marie-Charlotte Delaveau ◽  
Emile Daraï ◽  
Sofiane Bendifallah

Objectives: The aims of the study were to evaluate ultrasound (US) in the diagnosis of parametrial endometriosis compared with surgical-pathological findings, and to define an optimal cut-off of lesion size for correlation between torus/uterosacral ligaments (USL) or rectosigmoid and parametrial involvement by deep endometriosis. Methods: Longitudinal study of 60 patients referred for surgical management of pelvic endometriosis, who underwent sonography performed by an experienced sonographer. The presence of parametrial endometriosis shown by US was compared with surgical and histologic findings. The presence of endometrial cysts, deep endometriotic locations, and their potential association with parametrial endometriosis was assessed by US. The sensitivity, specificity, predictive values (PV), accuracy, and positive and negative likelihood ratios (LR) of US for predicting parametrial endometriosis and other pelvic endometriotic locations were assessed. Descriptive analysis, optimal cut-off analysis, categorical (Fisher’s exact test) and non-categorical variables (Mann—Whitney) were calculated. Results: Parametrial, ovarian, and deep endometriosis were found by surgery in respectively 30 (50%), 21 (35%), and 59 (98.63%) of the 60 patients. The sensitivity, specificity, PPV, NPV, accuracy, PLR, and NLR of US for the sonographic diagnosis of parametrial endometriosis were 40%, 96.7%, 92.3%, 61.7%, 68.3%, 12, and 0.62 respectively. In patients with parametrial involvement, a relation with rectosigmoid ( p = 0.005) and USL ( p = 0.0074) endometriosis was noted. For isolated torus/USL and rectosigmoid endometriosis, optimal cut-offs suggesting parametrial involvement by DE were 11 mm and 30 mm, respectively. Conclusions: US has low sensitivity but high specificity to diagnose parametrial endometriosis and could be used to rule in diagnosis before surgery.

2017 ◽  
Vol 55 (1) ◽  
pp. 82-90 ◽  
Author(s):  
Shu-Dao Xiong ◽  
Lian-Fang Pu ◽  
Hui-Ping Wang ◽  
Lin-Hui Hu ◽  
Yang-Yang Ding ◽  
...  

Abstract Background: In the hematology department, the availability of biomarkers for early detection of infection is difficult to obtain. The present study aimed to compare the diagnostic values of neutrophil CD64 Index, procalcitonin (PCT), interleukin-6 (IL-6) and C-reactive protein (CRP) and to determine whether the combined analysis of these biomarkers offer stronger predictive power in the diagnosis for the infection of febrile patients. Methods: Neutrophil CD64 Index, PCT, IL-6 and CRP levels were determined in 356 febrile patients in the hematology ward from May 2013 to May 2015. Sensitivity, specificity, positive and negative likelihood ratios, positive and negative predictive values, receiver operating characteristic (ROC) areas under the curve (AUC), and logistic regression analysis were determined to evaluate the diagnostic values of these biomarkers. Results: The levels of the four biomarkers were higher in the infection patients (p<0.001), and the PCT and IL-6 were higher in the patients with positive microbial blood culture (p<0.01). The neutrophil CD64 Index, PCT, IL-6, CRP had AUCs of 0.95, 0.83, 0.75 and 0.73, respectively. The best cut-off value of the neutrophil CD64 Index to detect infections was 5.06, with high specificity (87.5%) and sensitivity (88.4%). Furthermore, neutrophil CD64 Index, PCT and IL-6 offered the best combination of diagnosis with sensitivity of 93.9% and an AUC of 0.95. In addition, the neutrophil CD64 Index may have a special value to assist the physician to diagnose infection in the neutropenic patients with fever. Conclusions: The neutrophil CD64 Index is useful for early identification of infections in febrile patients in the hematology department. The combined analysis of the CD64 Index, PCT and IL-6 could further improve its sensitivity.


Author(s):  
Luma Cordeiro Rodrigues ◽  
Silvia Ferrite ◽  
Ana Paula Corona

Abstract Purpose This article investigates the validity of a smartphone-based audiometry for hearing screening to identify hearing loss in workers exposed to noise. Research Design This is a validation study comparing hearing screening with the hearTest to conventional audiometry. The study population included all workers who attended the Brazilian Social Service of Industry to undergo periodic examinations. Sensitivity, specificity, the Youden index, and positive (PPV) and negative predictive values (NPV) for hearing screening obtained by the hearTest were estimated according to three definitions of hearing loss: any threshold greater than 25 dB hearing level (HL), the mean auditory thresholds for 0.5, 1, 2, and 4 kHz greater than 25 dB HL, and the mean thresholds for 3, 4, and 6 kHz greater than 25 dB HL. Note that 95% confidence intervals were calculated for all measurements. Results A total of 232 workers participated in the study. Hearing screening with the hearTest presented good sensitivity (93.8%), specificity (83.9%), and Youden index (77.7%) values, a NPV (97.2%), and a low PPV (69.0%) for the identification of hearing loss defined as any auditory threshold greater than 25 dB HL. For the other definitions of hearing loss, we observed high specificity, PPV and NPV, as well as low sensitivity and Youden index. Conclusion The hearTest is an accurate hearing screening tool to identify hearing loss in workers exposed to noise, including those with noise-induced hearing loss, although it does not replace conventional audiometry.


2008 ◽  
Vol 9 (4) ◽  
pp. 278-284 ◽  
Author(s):  
P.P.G.M. Rooijens ◽  
G.P Serafino ◽  
D. Vroegindeweij ◽  
R. Dammers ◽  
T.I. Yo ◽  
...  

Purpose A method of diagnosing the extent and severity of arteriovenous fistula (AVF) stenoses is multi-slice computed tomographic angiography (MS-CTA). The aim of this prospective study was to assess the accuracy of MS-CTA for the detection and grading of stenoses in AVF in comparison to digital subtraction angiography (DSA), which was used as the gold standard of reference. Methods Fifteen hemodialysis (HD) patients with dysfunctioning forearm AVF were included. These AVFs were evaluated by both DSA and MS-CTA and were read in a prospective, blinded manner by two radiologists experienced in vascular imaging. Results ROC analysis revealed areas under the curve of 0.90 ± 0.07 for observer I and 0.87 ± 0.08 for observer II at a stenosis cut-off level of ≥50% diameter reduction. The combined results for MS-CTA showed sensitivity, specificity and positive and negative predictive values of 82%, 98%, 82% and 98% for stenoses ≥50% and 71%, 99%, 77% and 98% for stenoses ≥75%. Inter-observer agreement for the detection of stenoses ≥50% diameter reduction was 0.70 and 1.0, for MS-CTA and DSA, respectively. Conclusion MS-CTA can provide good visualization of forearm HD access AVF and has moderate sensitivity, but high specificity for the detection of flow-limiting stenoses.


Diagnostics ◽  
2019 ◽  
Vol 9 (3) ◽  
pp. 109 ◽  
Author(s):  
Ukweh ◽  
Ugbem ◽  
Okeke ◽  
Ekpo

Background: Ultrasound is operator-dependent, and its value and efficacy in fetal morphology assessment in a low-resource setting is poorly understood. We assessed the value and efficacy of fetal morphology ultrasound assessment in a Nigerian setting. Materials and Methods: We surveyed fetal morphology ultrasound performed across five facilities and followed-up each fetus to ascertain the outcome. Fetuses were surveyed in the second trimester (18th–22nd weeks) using the International Society of Ultrasound in Obstetrics and Gynecology (ISUOG) guideline. Clinical and surgical reports were used as references to assess the diagnostic efficacy of ultrasound in livebirths, and autopsy reports to confirm anomalies in terminated pregnancies, spontaneous abortions, intrauterine fetal deaths, and still births. We calculated sensitivity, specificity, positive and negative predictive values, Area under the curve (AUC), Youden index, likelihood ratios, and post-test probabilities. Results: In total, 6520 fetuses of women aged 15–46 years (mean = 31.7 years) were surveyed. The overall sensitivity, specificity, and AUC were 77.1 (95% CI: 68–84.6), 99.5 (95% CI: 99.3–99.7), and 88.3 (95% CI: 83.7–92.2), respectively. Other performance metrics were: positive predictive value, 72.4 (95% CI: 64.7–79.0), negative predictive value, 99.6 (95% CI: 99.5–99.7), and Youden index (77.1%). Abnormality prevalence was 1.67% (95% CI: 1.37–2.01), and the positive and negative likelihood ratios were 254 (95% CI: 107.7–221.4) and 0.23 (95% CI: 0.16–0.33), respectively. The post-test probability for positive test was 72% (95% CI: 65–79). Conclusion: Fetal morphology assessment is valuable in a poor economics setting, however, the variation in the diagnostic efficacy across facilities and the limitations associated with the detection of circulatory system anomalies need to be addressed.


CJEM ◽  
2018 ◽  
Vol 20 (5) ◽  
pp. 732-735 ◽  
Author(s):  
Sameer Sharif ◽  
Steven Skitch ◽  
Dean Vlahaki ◽  
Andrew Healey

ABSTRACTObjectivesAppendicitis is a common surgical condition that frequently requires diagnostic imaging. Abdominal computed tomography (CT) is the gold standard for diagnosing appendicitis. Ultrasound offers a radiation-free modality; however, its availability outside business hours is limited in many emergency departments (EDs). The purpose of this study is to evaluate the test characteristics of emergency physician-performed point-of-care ultrasound (POCUS) to diagnose appendicitis in a Canadian ED.MethodsA health records review was performed on all ED patients who underwent POCUS to diagnose appendicitis from December 1, 2010 to December 4, 2015. The sensitivity, specificity, and likelihood ratios were calculated. The gold standard used for diagnosis was pathology, laparoscopy, CT scans, and a radiologist-performed ultrasound.ResultsNinety patients were included in the study, and 24 were diagnosed with appendicitis on POCUS. Ultimately, 18 were confirmed to have appendicitis through radiologist-performed imaging, laparoscopy, and pathology. The sensitivity and specificity of POCUS to diagnose appendicitis were 69.2% (95% CI, 48.1%-84.9%) and 90.6% (95% CI, 80.0%-96.1%), respectively.ConclusionPOCUS has a high specificity for diagnosing acute appendicitis and has very similar characteristics to those of a radiologist-performed ultrasound. These findings are consistent with the current literature and have the potential to decrease patient morbidity, diagnostic delays, ED length of stay, and need for additional imaging.


2019 ◽  
Vol 2019 ◽  
pp. 1-7 ◽  
Author(s):  
Konuralp Yakar

Aim. To compare the clinical performance of the Spot Vision Screener used to detect amblyopia risk factors (ARFs) in children before and after induction of cycloplegia; the children were referred because they met the screening criteria of the American Association for Pediatric Ophthalmology and Strabismus (AAPOS). Methods. The Spot Vision Screener and a standard autorefractometer were used to examine 200 eyes of 100 children aged 3–10 years, before and after cycloplegia induction, in terms of ARFs. Sensitivity, specificity, and positive and negative predictive values for the detection of significant refractive errors were measured using the AAPOS referral criteria. It was explored that Spot Screener data were affected by cycloplegia. The extent of agreement between cycloplegic/noncycloplegic photoscreening data and cycloplegic autorefraction measurements was assessed using Wilcoxon and Spearman correlation analyses. Results. The Spot’s sensitivity was improved from 60.9% to 85.3% and specificity from 94.9% to 87.4% with cycloplegia compared to cycloplegic standard autorefractometer results. The positive predictive value of Spot was 75.7%, and the negative predictive value was 90.4% without cycloplegia. With cycloplegia, the positive predictive value of Spot was 63.6% and the negative predictive value was 95.8%. Conclusions. The Spot Screener afforded moderate sensitivity and high specificity prior to cycloplegia. The sensitivity and negative predictive value improved after induction of cycloplegia. Examiners should be aware of the effects of cycloplegia on their findings.


Lupus ◽  
2016 ◽  
Vol 26 (6) ◽  
pp. 606-615 ◽  
Author(s):  
Y Zuo ◽  
R Willis ◽  
E Papalardo ◽  
M Petri ◽  
E N Harris ◽  
...  

Background While essential for the classification of antiphospholipid syndrome (APS), anticardiolipin (aCL) assays lack specificity and anti-β2glycoproteinI (anti-β2GPI) assays lack sensitivity in this regard. Our aim was to perform a comparative analysis of the APhL ELISA assay (IgG/IgM) and criteria antiphospholipid (aPL) immunoassays in identifying APS-related clinical manifestations in a large group of patients with systemic lupus erythematosus (SLE). Methods Serum samples from 1178 patients from the Hopkins ( n = 543), LUMINA ( n = 588) and Jamaican SLE cohorts ( n = 47) were examined for IgG/IgM positivity in aCL (in-house), anti-β2GPI (two commercial kits) and APhL (Louisville APL) ELISA assays. Correlation of assay positivity with clinical manifestations and sensitivity, specificity, positive and negative predictive values and likelihood ratios were evaluated. A case series analysis was also performed in patients for whom there was isolated positivity in the specific aPL assays. Results The prevalence of aCL positivity was 34.9%, anti-β2GPI kit A was 22.6%, APhL was 11.5% and anti-β2GPI kit B was 7.6% in the study population. Anti-β2GPI kit B, aCL and APhL assays were correlated with venous thrombosis, while only APhL was significantly correlated with arterial thrombosis and consistently correlated with pregnancy-related morbidity. No significant correlations were noted for anti-β2GPI kit A. Sensitivity was greatest for aCL assays followed by anti-β2GPI kit A, APhL and anti-β2GPI kit B, while specificity was greatest and equal for anti-β2GPI kit B and APhL assays. Conclusions Overall, APhL antibodies, especially IgG, represent a promising biomarker for the classification of APS patients in the context of autoimmunity and in risk assessment with regards to pregnancy morbidity and thrombotic manifestations.


Sign in / Sign up

Export Citation Format

Share Document