scholarly journals Comparing Knee Laxity After Anatomic Anterior Cruciate Ligament Reconstruction Using Quadriceps Tendon Versus Semitendinosus Tendon Graft

2021 ◽  
Vol 9 (7) ◽  
pp. 232596712110148
Author(s):  
Katrin Karpinski ◽  
Martin Häner ◽  
Sebastian Bierke ◽  
Theresa Diermeier ◽  
Wolf Petersen

Background: The choice of graft in anterior cruciate ligament (ACL) reconstruction is still under discussion. The hamstrings are currently the most used grafts for primary ACL reconstruction in Europe. However, increased interest has arisen in the quadriceps tendon (QT) as an alternative autologous graft option for primary ACL reconstruction. Purpose: To evaluate knee stability and the subjective outcome after ACL reconstruction using either autologous QT graft in implant-free femoral press-fit fixation technique or semitendinosus tendon (ST) graft. Study Design: Cohort study; Level of evidence, 2. Methods: We evaluated 50 patients who underwent ACL reconstruction, including 25 patients who received autologous ipsilateral QT graft (QT group) and 25 patients who received the ipsilateral ST graft (ST group). The follow-up for this prospective comparative study was at least 2 years after surgery, comprising KT-1000 arthrometer testing, pivot-shift test, Knee injury and Osteoarthritis Outcome Score (KOOS), Lysholm score, and rerupture rate. Results: The mean patient age was 31.72 years (9 women, 16 men) in the QT group and 32.08 years (13 women, 12 men) in the ST group. The mean ± standard deviation postoperative side-to-side difference assessed using KT-1000 arthrometer was 1.56 ± 1.56 mm for the QT group and 1.64 ± 1.41 mm for the ST group, with no significant difference. No significant difference was found on any of the KOOS subscale scores ( P = .694) or the Lysholm score ( P = .682). No rerupture or positive pivot-shift test occurred during follow-up. No difference was found in donor-site morbidity between the study groups. Conclusion: Clinical outcomes were not significantly different between QT and ST grafts in the current study. Thus, the QT may serve as a good alternative graft for primary ACL reconstruction.

Author(s):  
Nadia Nastassia Ifran ◽  
Ying Ren Mok ◽  
Lingaraj Krishna

AbstractThe aim of the study is to compare the tear rates of ipsilateral anterior cruciate ligament (ACL) grafts and the contralateral native ACL as well as to investigate the correlation of gender, age at time of surgery, and body mass index (BMI) with the occurrence of these injuries. The medical records of 751 patients who underwent ACL reconstruction surgery with follow-up periods of 2 to 7 years were retrospectively analyzed. Survival analyses of ipsilateral ACL grafts and contralateral native ACL were performed. Univariate and multivariate logistic regression analyses were performed to identify risk factors that were associated with these injuries. The tear rates of the ipsilateral ACL graft and contralateral ACL were 5.86 and 6.66%, respectively with no significant difference between groups (p = 0.998). The mean time of tears of the ipsilateral ACL and contralateral ACL was also similar (p = 0.977) at 2.64 and 2.78 years, respectively after surgery. Both the odds of sustaining an ipsilateral ACL graft and contralateral ACL tear were also significantly decreased by 0.10 (p = 0.003) and 0.14 (p = 0.000), respectively, for every 1-year increase in age at which the reconstruction was performed. However, graft type, gender, and BMI were not associated with an increased risk of these injuries. There was no difference between tear rates of ipsilateral ACL graft and contralateral ACL following ACL reconstruction. Patients who undergo ACL reconstruction at a young age are at an increased risk of both ipsilateral graft and contralateral ACL rupture after an ACL reconstruction. Patients who are young and more likely to return to competitive sports should be counselled of the risks and advised to not neglect the rehabilitation of the contralateral knee during the immediate and back to sports period of recovery. This is a Level III, retrospective cohort study.


2012 ◽  
Vol 41 (1) ◽  
pp. 101-106 ◽  
Author(s):  
Nam-Hong Choi ◽  
Jong-Seok Oh ◽  
Seok-Hyun Jung ◽  
Brian N. Victoroff

Background: Previous reports have shown that graft fixation with the Endobutton is associated with tunnel widening because it provides distant fixation rather than aperture fixation. Hypothesis: A longer loop of the Endobutton results in greater tunnel widening than a shorter loop. Study Design: Cohort study; Level of evidence, 3. Methods: A total of 171 consecutive patients underwent hamstring anterior cruciate ligament (ACL) reconstruction fixed with the Endobutton. They were followed for a minimum of 2 years postoperatively. A 15-mm loop was used in 20 patients, a 20-mm loop in 53, a 25-mm loop in 58, and a >30-mm loop in 40. On anterior-posterior (AP) and lateral radiographs, the measured diameters of the femoral tunnel at 2 years after surgery were compared with the diameter of the reamer used at surgery. The measured diameter of the tibial tunnel at 2 years after surgery was compared with measurements taken on the immediate postoperative day. The center of the tibial tunnel and direction of the ACL graft were also measured. Postoperative knee stability was evaluated using the Lachman test, pivot-shift test, and KT-1000 arthrometer. Functional evaluations were performed using the Lysholm score and Tegner activity scale. All measurements were compared among the 4 groups according to the length of the Endobutton loop. Results: The mean ± standard deviation (SD) diameter of the femoral tunnel increased by 50.7% ± 23.3% and 37.0% ± 18.8% on AP and lateral radiographs at 2 years after surgery, respectively. The mean ± SD diameter of the tibial tunnel increased by 40.8% ± 19.3% and 46.4% ± 22.6% on AP and lateral radiographs, respectively. No significant difference in tunnel widening was present according to the length of the Endobutton loop. There were no significant differences in the average center of the tibial tunnel or the average angle of the direction of the ACL graft among the 4 groups. There was no significant difference in Lachman test results, postoperative KT-1000 arthrometer side-to-side differences, Lysholm score, and Tegner activity scale score among the 4 groups. The group with a >30-mm loop showed a significant difference in the pivot-shift test than the other 3 groups ( P = .023). Conclusion: A longer Endobutton loop did not result in greater tunnel widening than a shorter loop. Long fixation distance may not be associated with tunnel widening after hamstring ACL reconstructions.


Author(s):  
Ştefan Mogoş ◽  
Riccardo D'Ambrosi ◽  
Dinu Antonescu ◽  
Ioan-Cristian Stoica

AbstractThe purpose of the current randomized clinical trial (RCT) was to evaluate the clinical outcomes of combined anterior cruciate ligament (ACL) and anterolateral ligament (ALL) reconstruction and to compare them with those of isolated ACL reconstruction. The hypothesis was that combined ACL and ALL reconstruction will result in superior clinical outcomes in terms of the rotational stability of the knee. This prospective RCT included 57 patients (44 men and 13 women, mean age = 31 ± 7.1 years) who underwent ACL reconstruction either isolated (Group I: 25 patients) or combined with ALL reconstruction (Group II: 32 patients). The evaluation of the patients was done preoperatively and postoperatively at 6 weeks, 12 weeks, 6 months, and 12 months including a clinical examination (Lachman's test, Pivot shift's test, and Rolimeter differential anterior laxity), an objective clinical scores (objective: the International Knee Documentation Committee [IKDC] score) and a subjective clinical scores (subjective: IKDC's score, Lysholm's score, and Tegner's activity score). Postoperative complications of all the patients were recorded. There was a significant difference between the study groups at all follow-up intervals when evaluating the postoperative pivot shift test (p < 0.05) with a superior rotational stability in the group of combined ACL and ALL reconstruction. At the final follow-up evaluation, 36% of the patients from Group I and 6.2% in Group II had a grade I positive pivot shift test (p < 0.05). There was a statistically significant difference between the two groups regarding the number of patients with a grade A IKDC objective score (p < 0.05) at the 6- and 12-month follow-up intervals (p = 0.007). There was a significant difference concerning the IKDC subjective score between the two study groups in favor of the combined ACL and ALL reconstruction group at 12 months postoperatively (p = 0.048). Combined ACL and ALL reconstruction technique was demonstrated to be effective in obtaining a superior control of the rotational knee instability and to improve the clinical objective and subjective outcomes when compared with isolated ACL reconstruction in sports patients with high-grade pivoting shifts.


2019 ◽  
Vol 7 (12) ◽  
pp. 232596711989006
Author(s):  
Jose R. Perez ◽  
Christopher P. Emerson ◽  
Carlos M. Barrera ◽  
Dylan N. Greif ◽  
William H. Cade ◽  
...  

Background: Quadriceps tendon (QT)–bone autografts used during anterior cruciate ligament (ACL) reconstruction have provided comparable outcomes and decreased donor-site morbidity when compared with bone–patellar tendon–bone (BPTB) autografts. No study has directly compared the outcomes of the all–soft tissue QT autograft with that of the BPTB autograft. Hypothesis: Patient-reported knee outcome scores and rates of postoperative complication after primary ACL reconstruction with QT autografts are no different from BPTB autografts at a minimum 2-year follow-up. Study Design: Cohort study; Level of evidence, 3. Methods: A total of 75 patients who underwent primary autograft ACL reconstruction with QT or BPTB autografts between January 1, 2015, and March 31, 2016, at a single hospital center were contacted by telephone and asked to complete the International Knee Documentation Committee (IKDC) Subjective Knee Evaluation, Tegner activity level scale, and Lysholm knee scoring scale. Information about the subsequent surgeries performed on the operative knee was also collected. Statistical analysis was performed using the Kruskal-Wallis test and the Fisher exact test for categorical data. Results: Fifty patients (28 QT, 22 BPTB) completed the surveys at a mean follow-up of 33.04 months (range, 24-44 months). For the QT versus the BPTB group respectively, the median IKDC scores were 94.83 (interquartile range [IQR], 7.61) versus 94.83 (IQR, 10.92) ( P = .47), the median Tegner scores were 6 (IQR, 2.5) versus 6 (IQR, 2.75) ( P = .48), and the median Lysholm scores were 95 (IQR, 9) versus 95 (IQR, 13) ( P = .27). Additionally, 2 QT patients and 3 BPTB patients required follow-up arthroscopy for arthrolysis ( P = .64). There was 1 graft failure in the QT group requiring revision surgery. Conclusion: There was no statistical difference in patient-reported knee outcomes or graft complication rates between the QT and BPTB autograft groups at a minimum 2-year follow-up after primary ACL reconstruction. This study highlights that the all–soft tissue QT autograft may be a suitable graft choice for primary ACL reconstruction.


2017 ◽  
Vol 45 (6) ◽  
pp. 1326-1332 ◽  
Author(s):  
Etienne Cavaignac ◽  
Benoit Coulin ◽  
Philippe Tscholl ◽  
Nik Nik Mohd Fatmy ◽  
Victoria Duthon ◽  
...  

Background: The quadriceps tendon (QT) autograft is known as an effective graft for anterior cruciate ligament (ACL) reconstruction and shows a similar functional outcome to the bone-patellar tendon-bone (BPTB) in randomized controlled trials, with a lesser incidence of complications. Up until now, only 2 studies have compared QT to hamstring tendon (HT) autograft. Hypothesis: The functional outcomes of the QT technique are at least as good as those of the HT technique, with the same morbidity. Study Design: Cohort study; Level of evidence, 3. Methods: Ninety-five patients underwent isolated ACL reconstruction between January 1 and December 31, 2012. Fifty underwent ACL reconstruction with the QT and 45 with the HT. The same surgical technique, fixation method, and postoperative protocol were used in both groups. The following parameters were evaluated: surgical revisions, functional outcome (Lysholm, Knee injury and Osteoarthritis Outcome Score [KOOS], Tegner, subjective International Knee Documentation Committee), joint stability (KT-1000, Lachman, pivot shift), anterior knee pain (Shelbourne-Trumper score), and isokinetic strength. Descriptive statistics are presented for these variables using the Student t test. Results: Eighty-six patients (45 QT, 41 HT) were reviewed with a mean follow-up of 3.6 ± 0.4 years; minimum follow-up was 3 years. There were 4 reoperations in the QT group (including 1 ACL revision) and 3 in the HT group (including 2 ACL revisions) ( P > .05). The Lysholm (89 ± 6.9 vs 83.1 ± 5.3), KOOS Symptoms (90 ± 11.2 vs 81 ± 10.3), and KOOS Sport (82 ± 11.3 vs 67 ± 12.4) scores were significantly better in the QT group than in the HT group. In terms of stability, the mean side-to-side difference was 1.1 ± 0.9 mm for the QT group and 3.1 ± 1.3 mm for the HT group based on KT-1000 measurements ( P < .005). The negative Lachman component was higher in the QT group than in the HT group (90% vs 46%, P < .005). There was a trend for the negative pivot-shift component to be higher in the QT group than in the HT group (90% vs 64%, P = .052). The Shelbourne-Trumper score was the same in both groups. There was no difference between groups in terms of isokinetic strength. Conclusion: The use of a QT graft in ACL reconstruction leads to equal or better functional outcomes than does the use of an HT graft, without affecting morbidity.


2020 ◽  
Vol 7 (1) ◽  
Author(s):  
Willem Van Der Merwe ◽  
Martin Lind ◽  
Peter Faunø ◽  
Kees Van Egmond ◽  
Stefano Zaffagnini ◽  
...  

Abstract Purpose To evaluate clinical ad radiological outcomes of anterior cruciate ligament (ACL) reconstruction with an immunochemically modified porcine patellar tendon xenograft controlled against human Achilles tendon allograft at 24-month minimum follow-up. Methods 66 patients undergoing arthroscopic ACL reconstruction were randomized into 2 groups: 34 allografts and 32 xenografts treated to attenuate the host immune response. Follow-up was 24-month minimum. Anterior knee stability was measured as KT − 1000 side-to-side laxity difference (respect to the contralateral healthy knee). Functional performance was assessed by one-legged hop test. Objective manual pivot-shift test and subjective (IKDC, Tegner and SF-36) outcomes were collected. MRI and standard X-Ray were performed. Results 61 subjects (32 allograft, 29 xenograft) were evaluated at 12 and 24 months. Six of the subjects in xenograft group (20.6%) got an infection attributed to a water-based pathogen graft contamination in processing. Intention-to-treat analysis (using the last observation carried forward imputation method) revealed higher KT − 1000 laxity in xenograft group at 24-month follow-up (P = .042). Also pivot-shift was higher in xenograft group at 12-month (P = .015) and 24-month follow-up (P = .038). Per-protocol analysis (missing/contaminated subjects excluded) did not revealed clinical differences between groups. Tibial tunnel widening in the allograft group was low, whereas xenograft tunnel widening was within the expected range of 20–35% as reported in the literature. No immunological reactivity was associated to xenograft group. Conclusions High infection rate (20.6%) was reported in xenograft group. Both groups of patients achieved comparable clinical outcomes if missing/contaminated subjects are excluded. Improved harvesting/processing treatments in future studies using xenografts for ACL reconstruction are needed to reduce infection rate, otherwise xenograft should not be used in ACL reconstruction. Level of evidence Multicenter and double-blinded Randomized Controlled Clinical Trial, Level I.


2021 ◽  
pp. 036354652110273
Author(s):  
Joshua S. Everhart ◽  
Sercan Yalcin ◽  
Kurt P. Spindler

Background: Several long-term (≥20 years) follow-up studies after anterior cruciate ligament (ACL) reconstruction have been published in recent years, allowing for a systematic evaluation of outcomes. Purpose: To summarize outcomes at ≥20 years after ACL reconstruction and identify patient and surgical factors that affect these results. Study Design: Systematic review; Level of evidence, 4. Methods: Prospective studies of primary ACL reconstructions with hamstring or bone–patellar tendon—bone (BTB) autograft via an arthroscopic or a mini-open technique and with a mean follow-up of ≥20 years were identified. When possible, the mean scores for each outcome measure were calculated. Factors identified in individual studies as predictive of outcomes were described. Results: Five studies met the inclusion and exclusion criteria with a total of 2012 patients. The pooled mean follow-up for patient-reported outcome measures was 44.2% (range, 29.6%-92.7%) and in-person evaluation was 33.2% (range, 29.6%-48.9%). Four studies (n = 584) reported graft tears at a mean rate of 11.8% (range, 2%-18.5%) and 4 studies (n = 773) reported a contralateral ACL injury rate of 12.2% (range, 5.8%-30%). Repeat non-ACL arthroscopic surgery (4 studies; n = 177) to the ipsilateral knee occurred in 10.4% (range, 9.5%-18.3%) and knee arthroplasty (1 study; n = 217) in 5%. The pooled mean of the International Knee Documentation Committee subjective knee function (IKDC) score was 79.1 (SD, 21.8 [3 studies; n = 644]). In 2 studies (n?= 221), 57.5% of patients continued to participate in strenuous activities. The IKDC-objective score was normal or nearly normal in 82.3% (n = 496; 3 studies), with low rates of clinically significant residual laxity. Moderate-severe radiographic osteoarthritis (OA) (IKDC grade C or D) was present in 25.9% of patients (n = 605; 3 studies). Medial meniscectomy is associated with increased risk of radiographic OA. Radiographic OA severity is associated with worse patient-reported knee function, but the association with knee pain is unclear. Conclusion: Currently available prospective evidence for ACL reconstruction with hamstring or BTB autograft provides several insights into outcomes at 20 years. The rates of follow-up at 20 years range from 30% to 93%. IKDC-objective scores were normal or nearly normal in 82% and the mean IKDC-subjective score was 79 points.


2016 ◽  
Vol 1 (s2) ◽  
pp. 23-26
Author(s):  
Octav Russu ◽  
Tiberiu Bățagă ◽  
Andrei-Marian Feier ◽  
Radu Prejbeanu ◽  
Radu Fleaca ◽  
...  

Abstract Introduction: Anterior cruciate ligament (ACL) rupture is one of the most common lesions in knee traumatology; therefore the number of ACL reconstructions is increasing worldwide. Usually, an anteromedial (AM) accessory portal is required in anatomical positioning of the femoral tunnel, which is not absolutely necessary in this technique. Aim: Assessment of all-inside ACL reconstruction preliminary clinical results with adjustable loops and buttons on both femoral and tibial surfaces. Method: Our prospective study included 28 subjects (19 male, 9 female) with chronic ACL ruptures. The mean age of the study population was 27.72 ± 8.23 years. In all cases ACL reconstruction was carried out with the use of quadrupled semitendinosus auto-grafts with adjustable loops and buttons on the femoral and tibial surfaces and anatomic placement of both tunnels, using an outside-in technique, with flipcutters (Arthrex®). Clinical and radiological evaluations were carried out before surgery and at 3 and 6 months postoperatively, with the Lysholm scoring system, the Tegner activity scale and anterior-posterior and latero-lateral X-rays. Anterior knee laxity was measured in 25° of flexion using a portable arthrometer (RolimeterTM, Aircast®) and maximum manual force. Results: During the final follow-up, the Lysholm score was good and excellent in 27 cases, with a mean Lysholm score of 95.55 ± 4.63; all results were classified as good. The mean preoperative Tegner activity score was 3.46 ± 1.71 (range: 1-7), and the post-operative mean score was 5.75 ± 2.24 (range: 2-10). We found no graft ruptures. Preoperative knee laxity measurements showed a mean displacement of 11.5 ± 3.1 mm and side-to-side differences of 5.6 ± 3.5 mm, while the postoperative measurements at the last follow-up were 6.3 ± 1.54 mm and 2.65 ± 1.86 mm, respectively. Conclusion: Short-term clinical outcomes of all-inside ACL restoration with anatomic placement femoral and tibial tunnels seem to recommend this surgical option, with good subjective and objective results. Additional research will have to prove the long-term success.


2019 ◽  
Vol 48 (1) ◽  
pp. 93-98 ◽  
Author(s):  
Alexia G. Gagliardi ◽  
Patrick M. Carry ◽  
Harin B. Parikh ◽  
Jay C. Albright

Background: The incidence of anterior cruciate ligament (ACL) injury in the adolescent population is increasing. The quadriceps tendon–patellar bone autograft (QPA) has been established as a reliable graft choice for ACL reconstruction in the adult population. Purpose: To investigate graft failure, ability to return to sport, patient-reported functional outcomes, joint laxity, and subsequent injury among adolescent patients >2 years after primary ACL reconstruction with the QPA. Study Design: Case series; Level of evidence, 4. Methods: Consecutive patients who underwent QPA ACL reconstruction performed by a single surgeon were identified from an existing database. Information available in the database included demographics, concomitant/subsequent injuries, surgical procedures, graft failure, return to sport, and Lachman examination collected by medical record review. Pediatric International Knee Documentation Committee (Pedi-IKDC) and Lysholm scores were collected by telephone or during a clinic visit >2 years postoperatively. Results: The final cohort included 81 of 104 consecutive adolescent patients aged 10 to 18 years (mean ± SD, 15.9 ± 1.7 years at the time of surgery) for whom follow-up information was collected at >2 years after surgery. The cumulative incidence of graft failure within the 36-month follow-up period was 1.2% (95% CI, 0.1%-11.4%). The rate of ipsilateral non-ACL injuries was similar (1.2%; 95% CI, 0.2%-7.6%). Contralateral ACL and non-ACL injuries requiring surgical intervention were documented in 9.8% (95% CI, 4.9%-19.5%). The median Pedi-IKDC score was 94 (interquartile range, 89-98). The median Lysholm score was 99.5 (interquartile range, 89.0-100.0). At 36 months after surgery, 87.9% (95% CI, 81.4%-94.9%) of individuals had returned to play. Conclusion: The quadriceps tendon–patellar autograft is a novel graft that demonstrates excellent stability and favorable patient-reported outcomes. Based on these results, the QPA is a reliable choice for primary ACL reconstruction in adolescent patients.


2020 ◽  
Vol 48 (14) ◽  
pp. 3525-3533
Author(s):  
Yuka Kimura ◽  
Eiji Sasaki ◽  
Yuji Yamamoto ◽  
Shizuka Sasaki ◽  
Eiichi Tsuda ◽  
...  

Background: One of the goals of anterior cruciate ligament (ACL) reconstruction is a meniscal protective effect on the knee. Despite the advancement of ACL reconstruction techniques, subsequent meniscal tears after ACL reconstruction remain a problem, and the risk factors for recurring lesions are still unclear. Purpose: To investigate the incidence of subsequent meniscal surgery after primary ACL reconstruction without revision ACL surgery and to determine the risk factors associated with this reoperation. Study Design: Case series; Level of evidence, 4. Methods: Overall, 518 patients who underwent primary ACL reconstruction between 2004 and 2012 at one instution participated in this study. Data on body mass index, graft type and femoral tunnel-drilling technique of ACL reconstruction, and location and type of meniscal injury and its treatment at ACL reconstruction were collected from medical records. Clinical outcomes were investigated, including side-to-side difference of anterior laxity, pivot-shift grade, and subsequent meniscal surgery without ACL insufficiency (at minimum 2-year follow-up). Results: The prevalence of tears to the medial meniscus (MM) at the primary ACL reconstruction was 43.6% (226/518), 140 of which were repaired; on the contrary, tears of the lateral meniscus (LM) had a prevalence of 55.8% (289/518), 42 of which were repaired. At a mean 30.3 months (range, 8-124 months) after ACL reconstruction, 20 patients (3.9%; 14 MM tears, 3 LM tears, 3 MM + LM tears) required meniscal surgery without ACL reinjury or recurrence of instability. Of these, 14 MMs and 3 LMs had been repaired at primary ACL reconstruction. The failure rates of repaired MM and LM were 10.0% (14/140) and 7.1% (3/42), respectively. The failure rate of MM repair using the all-inside technique (6/36) was significantly higher compared with no treatment, inside-out repair, or partial resection ( P = .045). In multiple regression analysis, the presence of MM injury at the time of ACL reconstruction (odds ratio [OR], 7.81; P = .003), the side-to-side difference of postoperative anterior tibial translation (OR, 1.91; P = .032), and follow-up period after ACL reconstruction (OR, 1.02; P = .003) were risk factors of subsequent meniscal surgery after ACL reconstruction. Conclusion: Incidence of subsequent meniscal surgery after successful ACL reconstruction was <5%. Presence of MM tear at the time of ACL reconsturuction, small amount of increased anterior laxity, and long-term period after ACL reconstruction were predictive of subsequent meniscal surgery.


Sign in / Sign up

Export Citation Format

Share Document