scholarly journals Influence of Three Auditory Profiles on Aided Speech Perception in Different Noise Scenarios

2021 ◽  
Vol 25 ◽  
pp. 233121652110237
Author(s):  
Mengfan Wu ◽  
Oscar M. Cañete ◽  
Jesper Hvass Schmidt ◽  
Michal Fereczkowski ◽  
Tobias Neher

Hearing aid (HA) users differ greatly in their speech-in-noise (SIN) outcomes. This could be because the degree to which current HA fittings can address individual listening needs differs across users and listening situations. In two earlier studies, an auditory test battery and a data-driven method were developed for classifying HA candidates into four distinct auditory profiles differing in audiometric hearing loss and suprathreshold hearing abilities. This study explored aided SIN outcome for three of these profiles in different noise scenarios. Thirty-one older habitual HA users and six young normal-hearing listeners participated. Two SIN tasks were administered: a speech recognition task and a “just follow conversation” task requiring the participants to self-adjust the target-speech level. Three noise conditions were tested: stationary speech-shaped noise, speech-shaped babble noise, and speech-shaped babble noise with competing dialogues. Each HA user was fitted with three HAs from different manufacturers using their recommended procedures. Real-ear measurements were performed to document the final gain settings. The results showed that HA users with mild hearing deficits performed better than HA users with pronounced hearing deficits on the speech recognition task but not the just follow conversation task. Moreover, participants with pronounced hearing deficits obtained different SIN outcomes with the tested HAs, which appeared to be related to differences in HA gain. Overall, these findings imply that current proprietary fitting strategies are limited in their ability to ensure good SIN outcomes, especially for users with pronounced hearing deficits, for whom the choice of device seems most consequential.

2005 ◽  
Vol 16 (09) ◽  
pp. 726-739 ◽  
Author(s):  
Rachel A. McArdle ◽  
Richard H. Wilson ◽  
Christopher A. Burks

The purpose of this mixed model design was to examine recognition performance differences when measuring speech recognition in multitalker babble on listeners with normal hearing (n = 36) and listeners with hearing loss (n = 72) utilizing stimulus of varying linguistic complexity (digits, words, and sentence materials). All listeners were administered two trials of two lists of each material in a descending speech-to-babble ratio. For each of the materials, recognition performances by the listeners with normal hearing were significantly better than the performances by the listeners with hearing loss. The mean separation between groups at the 50% point in signal-to-babble ratio on each of the three materials was ~8 dB. The 50% points for digits were obtained at a significantly lower signal-to-babble ratio than for sentences or words that were equivalent. There were no interlist differences between the two lists for the digits and words, but there was a significant disparity between QuickSIN™ lists for the listeners with hearing loss. A two-item questionnaire was used to obtain a subjective measurement of speech recognition, which showed moderate correlations with objective measures of speech recognition in noise using digits (r = .641), sentences (r = .572), and words (r = .673).


2019 ◽  
Vol 62 (4) ◽  
pp. 1051-1067 ◽  
Author(s):  
Jonathan H. Venezia ◽  
Allison-Graham Martin ◽  
Gregory Hickok ◽  
Virginia M. Richards

Purpose Age-related sensorineural hearing loss can dramatically affect speech recognition performance due to reduced audibility and suprathreshold distortion of spectrotemporal information. Normal aging produces changes within the central auditory system that impose further distortions. The goal of this study was to characterize the effects of aging and hearing loss on perceptual representations of speech. Method We asked whether speech intelligibility is supported by different patterns of spectrotemporal modulations (STMs) in older listeners compared to young normal-hearing listeners. We recruited 3 groups of participants: 20 older hearing-impaired (OHI) listeners, 19 age-matched normal-hearing listeners, and 10 young normal-hearing (YNH) listeners. Listeners performed a speech recognition task in which randomly selected regions of the speech STM spectrum were revealed from trial to trial. The overall amount of STM information was varied using an up–down staircase to hold performance at 50% correct. Ordinal regression was used to estimate weights showing which regions of the STM spectrum were associated with good performance (a “classification image” or CImg). Results The results indicated that (a) large-scale CImg patterns did not differ between the 3 groups; (b) weights in a small region of the CImg decreased systematically as hearing loss increased; (c) CImgs were also nonsystematically distorted in OHI listeners, and the magnitude of this distortion predicted speech recognition performance even after accounting for audibility; and (d) YNH listeners performed better overall than the older groups. Conclusion We conclude that OHI/older normal-hearing listeners rely on the same speech STMs as YNH listeners but encode this information less efficiently. Supplemental Material https://doi.org/10.23641/asha.7859981


2012 ◽  
Vol 23 (08) ◽  
pp. 590-605 ◽  
Author(s):  
Richard H. Wilson ◽  
Rachel McArdle ◽  
Kelly L. Watts ◽  
Sherri L. Smith

Background: The Revised Speech Perception in Noise Test (R-SPIN; Bilger, 1984b) is composed of 200 target words distributed as the last words in 200 low-predictability (LP) and 200 high-predictability (HP) sentences. Four list pairs, each consisting of two 50-sentence lists, were constructed with the target word in a LP and HP sentence. Traditionally the R-SPIN is presented at a signal-to-noise ratio (SNR, S/N) of 8 dB with the listener task to repeat the last word in the sentence. Purpose: The purpose was to determine the practicality of altering the R-SPIN format from a single SNR paradigm into a multiple SNR paradigm from which the 50% points for the HP and LP sentences can be calculated. Research Design: Three repeated measures experiments were conducted. Study Sample: Forty listeners with normal hearing and 184 older listeners with pure-tone hearing loss participated in the sequence of experiments. Data Collection and Analysis: The R-SPIN sentences were edited digitally (1) to maintain the temporal relation between the sentences and babble, (2) to establish the SNRs, and (3) to mix the speech and noise signals to obtain SNRs between –1 and 23 dB. All materials were recorded on CD and were presented through an earphone with the responses recorded and analyzed at the token level. For reference purposes the Words-in-Noise Test (WIN) was included in the first experiment. Results: In Experiment 1, recognition performances by listeners with normal hearing were better than performances by listeners with hearing loss. For both groups, performances on the HP materials were better than performances on the LP materials. Performances on the LP materials and on the WIN were similar. Performances at 8 dB S/N were the same with the traditional fixed level presentation and the descending presentation level paradigms. The results from Experiment 2 demonstrated that the four list pairs of R-SPIN materials produced good first approximation psychometric functions over the –4 to 23 dB S/N range, but there were irregularities. The data from Experiment 2 were used in Experiment 3 to guide the selection of the words to be used at the various SNRs that would provide homogeneous performances at each SNR and would produce systematic psychometric functions. In Experiment 3, the 50% points were in good agreement for the LP and HP conditions within both groups of listeners. The psychometric functions for List Pairs 1 and 2, 3 and 4, and 5 and 6 had similar characteristics and maintained reasonable separations between the HP and LP functions, whereas the HP and LP functions for List Pair 7 and 8 bisected one another at the lower SNRs. Conclusions: This study indicates that the R-SPIN can be configured into a multiple SNR paradigm. A more in-depth study with the R-SPIN materials is needed to develop lists that are systematic and reasonably equivalent for use on listeners with hearing loss. The approach should be based on the psychometric characteristics of the 200 HP and 200 LP sentences with the current R-SPIN lists discarded. Of importance is maintaining the synchrony between the sentences and their accompanying babble.


2018 ◽  
Author(s):  
Tim Schoof ◽  
Pamela Souza

Objective: Older hearing-impaired adults typically experience difficulties understanding speech in noise. Most hearing aids address this issue using digital noise reduction. While noise reduction does not necessarily improve speech recognition, it may reduce the resources required to process the speech signal. Those available resources may, in turn, aid the ability to perform another task while listening to speech (i.e., multitasking). This study examined to what extent changing the strength of digital noise reduction in hearing aids affects the ability to multitask. Design: Multitasking was measured using a dual-task paradigm, combining a speech recognition task and a visual monitoring task. The speech recognition task involved sentence recognition in the presence of six-talker babble at signal-to-noise ratios (SNRs) of 2 and 7 dB. Participants were fit with commercially-available hearing aids programmed under three noise reduction settings: off, mild, strong. Study sample: 18 hearing-impaired older adults. Results: There were no effects of noise reduction on the ability to multitask, or on the ability to recognize speech in noise. Conclusions: Adjustment of noise reduction settings in the clinic may not invariably improve performance for some tasks.


2021 ◽  
Author(s):  
Satyabrata Parida ◽  
Michael G. Heinz

SUMMARYListeners with sensorineural hearing loss (SNHL) struggle to understand speech, especially in noise, despite audibility compensation. These real-world suprathreshold deficits are hypothesized to arise from degraded frequency tuning and reduced temporal-coding precision; however, peripheral neurophysiological studies testing these hypotheses have been largely limited to in-quiet artificial vowels. Here, we measured single auditory-nerve-fiber responses to a natural speech sentence in noise from anesthetized chinchillas with normal hearing (NH) or noise-induced hearing loss (NIHL). Our results demonstrate that temporal precision was not degraded, and broader tuning was not the major factor affecting peripheral coding of natural speech in noise. Rather, the loss of cochlear tonotopy, a hallmark of normal hearing, had the most significant effects (both on vowels and consonants). Because distorted tonotopy varies in degree across etiologies (e.g., noise exposure, age), these results have important implications for understanding and treating individual differences in speech perception for people suffering from SNHL.


2003 ◽  
Vol 14 (02) ◽  
pp. 084-099 ◽  
Author(s):  
Francis K. Kuk ◽  
Lisa Potts ◽  
Michael Valente ◽  
Lidia Lee ◽  
Jay Picirrillo

The present study examined the phenomenon of acclimatization in persons with a severe-to-profound hearing loss. A secondary purpose was to examine the efficacy of a digital nonlinear power hearing aid that has a low compression threshold with expansion for this population. Twenty experienced hearing aid users wore the study hearing aids for three months and their performance with the study hearing aids was evaluated at the initial fitting, one month, and three months after the initial fitting. Performance of their current hearing aids was also evaluated at the initial fitting. Speech recognition testing was conducted at input levels of 50 dB SPL and 65 dB SPL in quiet, and 75 dB SPL in noise at a +10 SNR. Questionnaires were used to measure subjective performance at each evaluation interval. The results showed improvement in speech recognition score at the one-month evaluation over the initial evaluation. No significant improvement was seen at the three-month evaluation from the one-month visit. In addition, subjective and objective performance of the study hearing aids was significantly better than the participants' own hearing aids at all evaluation intervals. These results provided evidence of acclimatization in persons with a severe-to-profound hearing loss and reinforced the precaution that any trial of amplification, especially from linear to nonlinear mode, should consider this phenomenon.


2008 ◽  
Vol 19 (09) ◽  
pp. 686-695 ◽  
Author(s):  
Lisa Lucks Mendel ◽  
Julie A. Gardino ◽  
Samuel R. Atcherson

Background: Successful communication is necessary in health-care environments. Yet the presence of noise in hospitals, operating rooms, and dental offices may have a deleterious effect on health-care personnel and patients understanding messages accurately. The presence of a surgical mask and hearing loss may further affect speech perception. Purpose: To evaluate whether a surgical mask had an effect on speech understanding for listeners with normal hearing and hearing impairment when speech stimuli were administered in the presence or absence of dental office noise. Research Design: Participants were assigned to one of two groups based on hearing sensitivity in this quasi-experimental, cross-sectional study. Study Sample: A total of 31 adults participated in this study (1 talker, 15 listeners with normal hearing, and 15 with hearing impairment). The normal hearing group had thresholds of 25 dB HL or better at the octave frequencies from 250 through 8000 Hz while the hearing loss group had varying degrees and configurations of hearing loss with thresholds equal to or poorer than 25 dB HL for the same octave frequencies. Data Collection And Analysis: Selected lists from the Connected Speech Test (CST) were digitally recorded with and without a surgical mask present and then presented to the listeners in four conditions: without a mask in quiet, without a mask in noise, with a mask in quiet, and with a mask in noise. Results: A significant difference was found in the spectral analyses of the speech stimuli with and without the mask. The presence of a surgical mask, however, did not have a detrimental effect on speech understanding in either the normal-hearing or hearing-impaired groups. The dental office noise did have a significant effect on speech understanding for both groups. Conclusions: These findings suggest that the presence of a surgical mask did not negatively affect speech understanding. However, the presence of noise did have a deleterious effect on speech perception and warrants further attention in health-care environments.


Sign in / Sign up

Export Citation Format

Share Document