Speech Understanding Using Surgical Masks: A Problem in Health Care?

2008 ◽  
Vol 19 (09) ◽  
pp. 686-695 ◽  
Author(s):  
Lisa Lucks Mendel ◽  
Julie A. Gardino ◽  
Samuel R. Atcherson

Background: Successful communication is necessary in health-care environments. Yet the presence of noise in hospitals, operating rooms, and dental offices may have a deleterious effect on health-care personnel and patients understanding messages accurately. The presence of a surgical mask and hearing loss may further affect speech perception. Purpose: To evaluate whether a surgical mask had an effect on speech understanding for listeners with normal hearing and hearing impairment when speech stimuli were administered in the presence or absence of dental office noise. Research Design: Participants were assigned to one of two groups based on hearing sensitivity in this quasi-experimental, cross-sectional study. Study Sample: A total of 31 adults participated in this study (1 talker, 15 listeners with normal hearing, and 15 with hearing impairment). The normal hearing group had thresholds of 25 dB HL or better at the octave frequencies from 250 through 8000 Hz while the hearing loss group had varying degrees and configurations of hearing loss with thresholds equal to or poorer than 25 dB HL for the same octave frequencies. Data Collection And Analysis: Selected lists from the Connected Speech Test (CST) were digitally recorded with and without a surgical mask present and then presented to the listeners in four conditions: without a mask in quiet, without a mask in noise, with a mask in quiet, and with a mask in noise. Results: A significant difference was found in the spectral analyses of the speech stimuli with and without the mask. The presence of a surgical mask, however, did not have a detrimental effect on speech understanding in either the normal-hearing or hearing-impaired groups. The dental office noise did have a significant effect on speech understanding for both groups. Conclusions: These findings suggest that the presence of a surgical mask did not negatively affect speech understanding. However, the presence of noise did have a deleterious effect on speech perception and warrants further attention in health-care environments.

2017 ◽  
Vol 28 (01) ◽  
pp. 058-067 ◽  
Author(s):  
Samuel R. Atcherson ◽  
Lisa Lucks Mendel ◽  
Wesley J. Baltimore ◽  
Chhayakanta Patro ◽  
Sungmin Lee ◽  
...  

AbstractIt is generally well known that speech perception is often improved with integrated audiovisual input whether in quiet or in noise. In many health-care environments, however, conventional surgical masks block visual access to the mouth and obscure other potential facial cues. In addition, these environments can be noisy. Although these masks may not alter the acoustic properties, the presence of noise in addition to the lack of visual input can have a deleterious effect on speech understanding. A transparent (“see-through”) surgical mask may help to overcome this issue.To compare the effect of noise and various visual input conditions on speech understanding for listeners with normal hearing (NH) and hearing impairment using different surgical masks.Participants were assigned to one of three groups based on hearing sensitivity in this quasi-experimental, cross-sectional study.A total of 31 adults participated in this study: one talker, ten listeners with NH, ten listeners with moderate sensorineural hearing loss, and ten listeners with severe-to-profound hearing loss.Selected lists from the Connected Speech Test were digitally recorded with and without surgical masks and then presented to the listeners at 65 dB HL in five conditions against a background of four-talker babble (+10 dB SNR): without a mask (auditory only), without a mask (auditory and visual), with a transparent mask (auditory only), with a transparent mask (auditory and visual), and with a paper mask (auditory only).A significant difference was found in the spectral analyses of the speech stimuli with and without the masks; however, no more than ∼2 dB root mean square. Listeners with NH performed consistently well across all conditions. Both groups of listeners with hearing impairment benefitted from visual input from the transparent mask. The magnitude of improvement in speech perception in noise was greatest for the severe-to-profound group.Findings confirm improved speech perception performance in noise for listeners with hearing impairment when visual input is provided using a transparent surgical mask. Most importantly, the use of the transparent mask did not negatively affect speech perception performance in noise.


2018 ◽  
Author(s):  
Lien Decruy ◽  
Jonas Vanthornhout ◽  
Tom Francart

AbstractElevated hearing thresholds in hearing impaired adults are usually compensated by providing amplification through a hearing aid. In spite of restoring hearing sensitivity, difficulties with understanding speech in noisy environments often remain. One main reason is that sensorineural hearing loss not only causes loss of audibility but also other deficits, including peripheral distortion but also central temporal processing deficits. To investigate the neural consequences of hearing impairment in the brain underlying speech-in-noise difficulties, we compared EEG responses to natural speech of 14 hearing impaired adults with those of 14 age-matched normal-hearing adults. We measured neural envelope tracking to sentences and a story masked by different levels of a stationary noise or competing talker. Despite their sensorineural hearing loss, hearing impaired adults showed higher neural envelope tracking of the target than the competing talker, similar to their normal-hearing peers. Furthermore, hearing impairment was related to an additional increase in neural envelope tracking of the target talker, suggesting that hearing impaired adults may have an enhanced sensitivity to envelope modulations or require a larger differential tracking of target versus competing talker to neurally segregate speech from noise. Lastly, both normal-hearing and hearing impaired participants showed an increase in neural envelope tracking with increasing speech understanding. Hence, our results open avenues towards new clinical applications, such as neuro-steered prostheses as well as objective and automatic measurements of speech understanding performance.HighlightsAdults with hearing impairment can neurally segregate speech from background noiseHearing loss is related to enhanced neural envelope tracking of the target talkerNeural envelope tracking has potential to objectively measure speech understanding


2019 ◽  
Author(s):  
Lien Decruy ◽  
Jonas Vanthornhout ◽  
Tom Francart

AbstractElevated hearing thresholds in hearing impaired adults are usually compensated by providing amplification through a hearing aid. In spite of restoring hearing sensitivity, difficulties with understanding speech in noisy environments often remain. One main reason is that sensorineural hearing loss not only causes loss of audibility but also other deficits, including peripheral distortion but also central temporal processing deficits. To investigate the neural consequences of hearing impairment in the brain underlying speech-in-noise difficulties, we compared EEG responses to natural speech of 14 hearing impaired adults with those of 14 age-matched normal-hearing adults. We measured neural envelope tracking to sentences and a story masked by different levels of a stationary noise or competing talker. Despite their sensorineural hearing loss, hearing impaired adults showed higher neural envelope tracking of the target than the competing talker, similar to their normal-hearing peers. Furthermore, hearing impairment was related to an additional increase in neural envelope tracking of the target talker, suggesting that hearing impaired adults may have an enhanced sensitivity to envelope modulations or require a larger differential tracking of target versus competing talker to neurally segregate speech from noise. Lastly, both normal-hearing and hearing impaired participants showed an increase in neural envelope tracking with increasing speech understanding. Hence, our results open avenues towards new clinical applications, such as neuro-steered prostheses as well as objective and automatic measurements of speech understanding performance.HighlightsAdults with hearing impairment can neurally segregate speech from background noiseHearing loss is related to enhanced neural envelope tracking of the target talkerNeural envelope tracking has potential to objectively measure speech understanding


2000 ◽  
Vol 31 (4) ◽  
pp. 362-370 ◽  
Author(s):  
Carl C. Crandell ◽  
Joseph J. Smaldino

Past investigations demonstrate that the acoustical environment of a classroom is a critical factor in the academic, psychoeducational, and psychosocial achievement of children with normal hearing and with hearing impairment. This article examines several acoustical variables, such as noise, reverberation, and speaker-listener distance, which can deleteriously affect speech perception in classrooms. Moreover, the discussion examines the effects of these variables on the speech perception abilities of both children with normal hearing and children with hearing loss. Finally, appropriate acoustical criteria are suggested for children in educational settings.


2021 ◽  
pp. 1-8
Author(s):  
Mustafa Avcu ◽  
Mehmet Metin ◽  
Raşit Kılıç ◽  
Muhammed Alpaslan

Background: In this study, optic coherence tomography (OCT) examination was performed to check whether there was any interaction between ophthalmic axonal structures in unilateral tinnitus patients, and the relationship between optic nerve thickness and cochlear nerve thickness was evaluated. Objective: The aim of the study was to evaluate the relatioship between hearing loss, tinnitus, and nerve thicknesses. Study Design: Prospective study. Setting: Tertiary referral university hospital. Patients: The study included 88 patients with unilateral tinnitus, for which no organic cause could be found in physical examination, psychiatric evaluation, or with imaging methods. Study groups were formed of the tinnitus side and control groups were formed of the healthy side as follows: Group 1 (Non-tinnitus side normal hearing values – n = 30), Group 2 (non-tinnitus side minimal hearing loss – n = 27), Group 3 (non-tinnitus side moderate hearing loss – n = 31), Group 4 (tinnitus side normal hearing values – n = 25), Group 5 (tinnitus side minimal hearing loss – n = 25), and Group 6 (tinnitus side moderate hearing loss – n = 38). Intervention: Retinal nerve fiber layer (RNFL) thickness was evaluated with OCT, and the cochlear nerve cross-sectional area was evaluated with MRI. Main Outcome Measures: RNFL measurements were taken with OCT from the subfoveal area (RNFL-SF) and 1.5 mm temporal to the fovea (RNFL-T µm) and nasal (RNFL-N µm) sectors. On MRI, 3 measurements were taken along the nerve from the cerebellopontine angle as far as the internal auditory canal, and the mean value of these 3 measurements was calculated. Results: When the groups were evaluated in respect of cochlear nerve thickness, a significant difference was seen between Group 1 and both the groups with hearing loss and the tinnitus groups. In the subgroup analysis, a statistically significant difference was determined between Group 1 and Groups 3, 4, 5, and 6 (p = 0.013, p = 0.003, p < 0.001, and p < 0.001, respectively). When the groups were evaluated in respect of the RNFL-SF (µm), RNFL-T (µm), and RNFL-N (µm) values, the differences were determined to be statistically significant (p < 0.001 for all). In the correlation analysis, a negative correlation was determined between hearing loss and cochlear nerve diameter (r: −0.184, p = 0.014), and RNFL-N (r: −0.272, p < 0.001) and between tinnitus and cochlear nerve diameter (r: −0.536, p < 0.001), and RNFL-T (r: −0.222, p < 0.009). Conclusion: The study results clearly showed a relationship between cochlear nerve fiber thickness and hearing loss and the severity of tinnitus in cases with unilateral tinnitus and that there could be neurodegenerative factors in the disease etiology. A similar relationship seen with the RNFL supports the study hypothesis.


2021 ◽  
pp. 102986492110152
Author(s):  
Carl Hopkins ◽  
Saúl Maté-Cid ◽  
Robert Fulford ◽  
Gary Seiffert ◽  
Jane Ginsborg

This study investigated the perception and learning of relative pitch using vibrotactile stimuli by musicians with and without a hearing impairment. Notes from C3 to B4 were presented to the fingertip and forefoot. Pre- and post-training tests in which 420 pairs of notes were presented randomly were carried out without any feedback to participants. After the pre-training test, 16 short training sessions were carried out over six weeks with 72 pairs of notes per session and participants told whether their answers were correct. For amateur and professional musicians with normal hearing and professional musicians with a severe or profound hearing loss, larger pitch intervals were easier to identify correctly than smaller intervals. Musicians with normal hearing had a high success rate for relative pitch discrimination as shown by pre- and post-training tests, and when using the fingertips, there was no significant difference between amateur and professional musicians. After training, median scores on the tests in which stimuli were presented to the fingertip and forefoot were >70% for intervals of 3–12 semitones. Training sessions reduced the variability in the responses of amateur and professional musicians with normal hearing and improved their overall ability. There was no significant difference between the relative pitch discrimination abilities between one and 11 semitones, as shown by the pre-training test, of professional musicians with and without a severe/profound hearing loss. These findings indicate that there is potential for vibration to be used to facilitate group musical performance and music education in schools for the deaf.


2000 ◽  
Vol 37 (2) ◽  
pp. 166-171 ◽  
Author(s):  
S. Carrie ◽  
A. Sprigg ◽  
A.J. Parker

Objective This investigation was performed to determine if an easily measurable, reproducible, bony parameter could be identified that might predict hearing loss in cleft palate children. Subjects In this prospective study performed at the Sheffield Children's Hospital (U.K.), 34 children with successfully repaired cleft palate who responded to a postal request for volunteers were assessed clinically, audiologically, and by lateral soft tissue neck radiography. Six children were excluded because of previous otologic surgery or poor quality radiographs. Twenty-six children who had the same series of investigations were randomly selected from routine otolaryngological outpatient clinics and acted as controls. Methods The sphenopalatine angle (SPA), which relates the facial and cranial components of the skull, was measured on each child's radiograph. Results The median SPA in the cleft palate group was significantly greater than in the control group (p = 0.01). In those cleft palate children with a hearing loss the sphenopalatine angle was smaller than in their normal hearing counterparts (p = 0.01). No significant difference was found in the SPA between the hearing loss and normal hearing controls. There was no significant difference in age ranges between the hearing and hearing loss subgroups in each of the two primary groups. Conclusions In this study, those cleft palate children with a smaller SPA have a greater incidence of hearing loss.


2013 ◽  
Vol 131 (5) ◽  
pp. 289-295 ◽  
Author(s):  
Erica Endo Amemiya ◽  
Barbara Niegia Garcia Goulart ◽  
Brasilia Maria Chiari

CONTEXT AND OBJECTIVE: Nouns and verbs indicate actions in oral communication. However, hearing impairment can compromise the acquisition of oral language to such an extent that appropriate use of these can be challenging. The objective of this study was to compare the use of nouns and verbs in the oral narrative of hearing-impaired and hearing children. DESIGN AND SETTING: Analytical cross-sectional study at the Department of Speech-Language and Hearing Sciences, Universidade Federal de São Paulo. METHODS: Twenty-one children with moderate to profound bilateral neurosensory hearing impairment and twenty-one with normal hearing (controls) were matched according to sex, school year and school type. A board showing pictures was presented to each child, to elicit a narrative and measure their performance in producing nouns and verbs. RESULTS: Twenty-two (52.4%) of the subjects were males. The mean age was 8 years (standard deviation, SD = 1.5). Comparing averages between the groups of boys and girls, we did not find any significant difference in their use of nouns, but among verbs, there was a significant difference regarding use of the imperative (P = 0.041): more frequent among boys (mean = 2.91). There was no significant difference in the use of nouns and verbs between deaf children and hearers, in relation to school type. Regarding use of the indicative, there was a nearly significant trend (P = 0.058). CONCLUSION: Among oralized hearing-impaired children who underwent speech therapy, their performance regarding verbs and noun use was similar to that of their hearing counterparts.


2020 ◽  
Vol 5 (1) ◽  
pp. 36-39
Author(s):  
Mariya Yu. Boboshko ◽  
Irina P. Berdnikova ◽  
Natalya V. Maltzeva

Objectives -to determine the normative data of sentence speech intelligibility in a free sound field and to estimate the applicability of the Russian Matrix Sentence test (RuMatrix) for assessment of the hearing aid fitting benefit. Material and methods. 10 people with normal hearing and 28 users of hearing aids with moderate to severe sensorineural hearing loss were involved in the study. RuMatrix test both in quiet and in noise was performed in a free sound field. All patients filled in the COSI questionnaire. Results. The hearing impaired patients were divided into two subgroups: the 1st with high and the 2nd with low hearing aid benefit, according to the COSI questionnaire. In the 1st subgroup, the threshold for the sentence intelligibility in quiet was 34.9 ± 6.4 dB SPL, and in noise -3.3 ± 1.4 dB SNR, in the 2nd subgroup 41.7 ± 11.5 dB SPL and 0.15 ± 3.45 dB SNR, respectively. The significant difference between the data of both subgroups and the norm was registered (p


2018 ◽  
Vol 2018 ◽  
pp. 1-8 ◽  
Author(s):  
Tom Gawliczek ◽  
Wilhelm Wimmer ◽  
Fabio Munzinger ◽  
Marco Caversaccio ◽  
Martin Kompis

Objective. To measure the audiological benefit of the Baha SoundArc, a recently introduced nonimplantable wearing option for bone conduction sound processor, and to compare it with the known softband wearing option in subjects with normal cochlear function and a purely conductive bilateral hearing loss.Methods. Both ears of 15 normal hearing subjects were occluded for the time of the measurement, yielding an average unaided threshold of 49 dB HL (0.5 – 4 kHz). Soundfield thresholds, speech understanding in quiet and in noise, and sound localization were measured in unaided conditions and with 1 or 2 Baha 5 sound processors mounted on either a softband or a SoundArc device.Results. Soundfield thresholds and speech reception thresholds were improved by 19.5 to 24.8 dB (p<.001), when compared to the unaided condition. Speech reception thresholds in noise were improved by 3.7 to 4.7 dB (p<.001). Using 2 sound processors rather than one improved speech understanding in noise for speech from the direction of the2nddevice and sound localization error by 23° to 28°. No statistically significant difference was found between the SoundArc and the softband wearing options in any of the tests.Conclusions. Bone conduction sound processor mounted on a SoundArc or on a softband resulted in considerable improvements in hearing and speech understanding in subjects with a simulated, purely conductive, and bilateral hearing loss. No significant difference between the 2 wearing options was found. Using 2 sound processors improves sound localization and speech understanding in noise in certain spatial settings.