scholarly journals Length of Stay in Total Shoulder Arthroplasty: Does Day of Surgery Matter?

2019 ◽  
Vol 3 ◽  
pp. 247154921983215
Author(s):  
Jeffrey D Osborne ◽  
Christopher J Bush ◽  
Denise M Koueiter ◽  
J Michael Wiater

Purpose: With health-care utilization becoming an important factor in patient care, we investigated the effect that surgical day of week has on length of hospital stay (LOS) for shoulder arthroplasty patients.Methods: All patients undergoing primary anatomic or reverse total shoulder arthroplasty by a single surgeon on Monday, Wednesday, or Friday over a 10-year period were retrospectively reviewed. A total of 1784 patients met inclusion criteria. Demographics, LOS, and discharge disposition were recorded for all study participants.Results: The overall average LOS was 2.9 ± 1.8 days and was significantly longer for patients having surgery Friday (3.0 ± 1.9 days) versus Wednesday (2.7 ± 1.7 days, P = .002). For those discharged home, the mean LOS was 2.6 ± 1.3 days versus 4.3 ± 3.3 days for those discharged to extended care facilities (ECFs). Patients discharged to ECF with Friday surgery had a significantly longer LOS than Monday ( P = .028) and Wednesday ( P = .010) patients, with 30% of patients with Friday surgery being discharged postoperative day 4 versus 14% and 9% on Monday and Wednesday, respectively. LOS trended toward being longer for Friday surgery in the home disposition group but did not reach significance.Discussion: These results should be considered during surgical scheduling in order to minimize health-care expenditures. Patients at high risk for requiring ECF at discharge should be scheduled at the beginning of the week, while more resources are available to expedite their discharge.

2021 ◽  
pp. 175857322110193
Author(s):  
Arjun K Reddy ◽  
Jake X Checketts ◽  
B Joshua Stephens ◽  
J Michael Anderson ◽  
Craig M Cooper ◽  
...  

Background Thus, the purpose of the present study was to (1) characterize common postoperative complications and (2) quantify the rates of revision in patients undergoing hemiarthroplasty to reverse total shoulder arthroplasty revisional surgery. We hypothesize that hardware loosenings will be the most common complication to occur in the sample, with the humeral component being the most common loosening. Methods This systematic review adhered to PRISMA reporting guideline. For our inclusion criteria, we included any study that contained intraoperative and/or postoperative complication data, and revision rates on patients who had undergone revision reverse total shoulder arthroplasty due to a failed hemiarthroplasty. Complications include neurologic injury, deep surgical site infections, hardware loosening/prosthetic instability, and postoperative fractures (acromion, glenoid, and humeral fractures). Results The study contained 22 studies that assessed complications from shoulders that had revision reverse total shoulder arthroplasty from a hemiarthroplasty, with a total sample of 925 shoulders. We found that the most common complication to occur was hardware loosenings (5.3%), and of the hardware loosenings, humeral loosenings (3.8%) were the most common. The revision rate was found to be 10.7%. Conclusion This systematic review found that revision reverse total shoulder arthroplasty for failed hemiarthroplasty has a high overall complication and reintervention rates, specifically for hardware loosening and revision rates.


2021 ◽  
pp. 175857322110329
Author(s):  
Therese E Parr ◽  
Jennifer K Anderson ◽  
Alan M. Marionneaux ◽  
John M Tokish ◽  
Stefan J Tolan ◽  
...  

Background In a reverse total shoulder arthroplasty, the altered glenohumeral joint center of rotation subjects the glenoid baseplate to increased shear forces and potential loosening. Methods This study examined glenoid baseplate micromotion and initial fixation strength with the application of direct shear force in a Sawbone model. The reverse total shoulder arthroplasty systems examined were the DJO Reverse® Shoulder Prosthesis, the Exactech Equinoxe® Reverse System, and the Tornier AequalisTM Reverse Shoulder Prosthesis. Specimens were cyclically tested with increasing shear loads until 150 µm of displacement between the implant and glenoid was achieved, and subsequently until failure, classified as either 1 cm of implant/glenoid displacement or fracture. Results The average load withstood for the 150 µm threshold for DJO, Tornier, and Exactech was 460 ± 88 N, 525 ± 100 N, and 585 ± 160 N, respectively. The average total load at device failure for DJO, Tornier, and Exactech was 980 ± 260 N, 1260 ± 120 N, and 1350 ± 230 N, respectively. Discussion The Exactech implant design trended toward requiring more load to induce micromotion at each threshold and to induce device failure, most commonly seen as inferior screw pull out. This study proposes design features that may enhance fixation and suggests little risk of initial micromotion or failure during initial post-operative recovery.


2021 ◽  
pp. 110550
Author(s):  
Antonia M. Zaferiou ◽  
Christopher B. Knowlton ◽  
Suk-Hwan Jang ◽  
Bryan M. Saltzman ◽  
Nikhil N. Verma ◽  
...  

2019 ◽  
Vol 43 (11) ◽  
pp. 2579-2586 ◽  
Author(s):  
Edoardo Franceschetti ◽  
Edoardo Giovannetti de Sanctis ◽  
Riccardo Ranieri ◽  
Alessio Palumbo ◽  
Michele Paciotti ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document