scholarly journals Smartphone Applications for Assessing Ankle Range of Motion in Clinical Practice

2019 ◽  
Vol 4 (3) ◽  
pp. 247301141987477 ◽  
Author(s):  
Kevin Y. Wang ◽  
S. Hanif Hussaini ◽  
Robert D. Teasdall ◽  
Chukwuweike U. Gwam ◽  
Aaron T. Scott

Background: Measuring ankle range of motion (ROM) following injury or intervention is necessary for monitoring recovery as well as for calculating permanent impairment ratings in workers’ compensation cases. In recent years, smartphone application developers have created applications (apps) that emulate ROM measurement tools like the universal goniometer. This study assessed the correlation between smartphone ROM measurements and universal goniometer measurements, as well as the reliability and usability of these apps in clinical practice. Methods: Three raters used the Goniometer app (Gonio), Clinometer app (Clino), DrGoniometer app (DrG), and a universal goniometer (UG) to assess the ankle ROM in plantarflexion and dorsiflexion of 24 patients with ankle pathology. Each patient completed a survey on the usability of the apps. Results: Lin’s concordance correlation coefficient test showed moderate correlation between the smartphone and UG measurements (Lin‘s correlation coefficient [rLC] = 0.931, 95% confidence interval [CI] = 0.911-0.946 for UG-Gonio; rLC = 0.908, 95% CI = 0.881-0.929 for UG-Clino; rLC = 0.935, 95% CI = 0.915-0.950 for UG-DrG). A 2-way mixed model showed good to excellent interrater reliability for each app for plantarflexion and dorsiflexion (ICCp = 0.836, ICCd = 0.912, P < .001 for Gonio; ICCp = 0.788, ICCd = 0.893, P < .001 for Clino; ICCp = 0.777, ICCd = 0.897, P < .001 for DrG). Most participants surveyed were very comfortable with having their ankle ROM measured by a smartphone. Conclusion: Smartphone apps may be a more convenient way to measure ankle ROM than UG. Physicians can use these apps to measure a patient’s ROM in clinic, a patient could send a picture of his or her dorsiflexed or plantarflexed ankle to the physician to remotely track ROM, or a patient could measure his or her own ROM at home using a personal smartphone. Level of Evidence: Level IV, case series.

Author(s):  
Gabriele Colo’ ◽  
Mattia Alessio Mazzola ◽  
Giulio Pilone ◽  
Giacomo Dagnino ◽  
Lamberto Felli

Abstract The aim of this study is to evaluate the results of patients underwent lateral open wedge calcaneus osteotomy with bony allograft augmentation combined with tibialis posterior and tibialis anterior tenodesis. Twenty-two patients underwent adult-acquired flatfoot deformity were retrospectively evaluated with a minimum 2-year follow-up. Radiographic preoperative and final comparison of tibio-calcaneal angle, talo–first metatarsal and calcaneal pitch angles have been performed. The Visual Analog Scale, American Orthopedic Foot and Ankle Score, the Foot and Ankle Disability Index and the Foot and Ankle Ability Measure were used for subjective and functional assessment. The instrumental range of motion has been also assessed at latest follow-up evaluation and compared with preoperative value. There was a significant improvement of final mean values of clinical scores (p < 0.001). Nineteen out of 22 (86.4%) patients resulted very satisfied or satisfied for the clinical result. There was a significant improvement of the radiographic parameters (p < 0.001). There were no differences between preoperative and final values of range of motion. One failure occurred 7 years after surgery. Adult-acquired flatfoot deformity correction demonstrated good mid-term results and low recurrence and complications rate. Level of evidence Level 4, retrospective case series.


2018 ◽  
Vol 46 (13) ◽  
pp. 3155-3164 ◽  
Author(s):  
Vasanth Seker ◽  
Lisa Hackett ◽  
Patrick H. Lam ◽  
George A.C. Murrell

Background: Massive and irreparable rotator cuff tears are difficult to manage surgically. One technique is to use a synthetic polytetrafluoroethylene (PTFE) patch to bridge the tear. However, there is little information regarding the outcomes of this procedure. Purpose: To determine the ≥2-year outcomes of patients for whom synthetic patches were used as tendon substitutes to bridge irreparable rotator cuff defects. Study Design: Case series; Level of evidence, 4. Methods: This retrospective cohort study used prospectively collected data. Patients included those with a synthetic patch inserted as an interposition graft for large and/or irreparable rotator cuff tears with a minimum 2-year follow-up. Standardized assessment of shoulder pain, function, range of motion, and strength was performed preoperatively, at 6 and 12 weeks, and at 6 months and ≥2 years. Radiograph and ultrasound were performed preoperatively, at 6 months, and ≥2 years. Results: At a mean of 36 months, 58 of 68 eligible patients were followed up, and 53 of 58 (90%) patches remained in situ. Three patches failed at the patch-tendon interface, while 1 patient (2 shoulders/patches) went on to have reverse total shoulder replacements. Patient-ranked shoulder stiffness ( P < .001), frequency of pain with activity and sleep ( P < .0001), level of pain at rest and overhead ( P < .0001), and overall shoulder function improved from bad to very good ( P < .0001) by 6 months. Supraspinatus (mean ± SEM: 29 ± 16 N to 42 ± 13 N) and external rotation (39 ± 13 N to 59 ± 15 N) strength were the most notable increases at the ≥2-year follow-up ( P < .0001). Passive range of motion also improved by 49% to 67%; forward flexion, from 131° to 171°; abduction, from 117° to 161°; external rotation, from 38° to 55°; and internal rotation, from L3 to T10 ( P < .0001) preoperatively to ≥2 years. The most improvement in passive range of motion occurred between 12 months and ≥2 years. The mean (SD) Constant-Murley score was 90 (12), while the American Shoulder and Elbow Surgeons score was 95 (8). Conclusion: At 36 months postoperatively, patients who had synthetic patches used as tendon substitutes to bridge irreparable rotator cuff defects reported less pain and greater overall shoulder function as compared with preoperative assessments. They demonstrated improved range of passive motion and improved strength. The data support the hypothesis that the technique of using a synthetic PTFE patch to bridge a large and/or irreparable tear has good construct integrity and improves patient and clinical outcomes.


2020 ◽  
Vol 14 (3) ◽  
pp. 260-263
Author(s):  
Guillermo Arrondo ◽  
Daniel Gómez ◽  
Germán Joannas ◽  
Xavier Martín-Oliva ◽  
Matías Iglesias ◽  
...  

Objective: Impingement syndromes are recognized as an important cause of chronic ankle pain, which results from the entrapment of an inflamed soft-tissue component between the osteophytes. The predominant site of occurrence is the anterolateral aspect of the ankle for soft-tissue impingement, and anteromedial aspect for bony impingement. Symptoms related to the physical impact of bone or soft-tissue pain often result in limited ankle range of motion. Methods: We conducted a retrospective study of 34 patients (34 ankles) with anteromedial bony impingement. All patients underwent arthroscopy, with a mean follow-up of 34 months. Results: All osteophytes were removed, and the ankle range of motion improved. The AOFAS score improved from 73 preoperatively to 95 postoperatively. Conclusion: The arthroscopic removal of the anteromedial osteophytes of the ankle had excellent functional results. It is an effective procedure that allows rapid patient recovery. Level of Evidence IV; Therapeutic Studies; Case Series.


2018 ◽  
Vol 07 (04) ◽  
pp. 324-330
Author(s):  
Rémy Coulomb ◽  
Pascal Kouyoumdjian ◽  
Olivier Mares ◽  
Benjamin Degeorge

Purpose We retrospectively evaluated the results of all arthroscopic dorsal scapholunate (SL) capsuloplasty without pinning in patients presenting predynamic instability and dorsal capsuloscapholunate septum lesions on arthro–computed tomography scan after failed medical treatment. Materials and Methods Fifteen patients, mean age 34.3 years, underwent all arthroscopically assisted dorsal capsuloplasty. Patients were assessed preoperatively and postoperatively by a clinical (pain, Watson's test, range of motion, and strength), functional (quick disabilities of the arm, shoulder, and hand), patient-rated wrist evaluation, and Mayo wrist score scores), and radiological (SL gap and dorsal intercalated segmental instability [DISI]) examination. SL tears were evaluated during surgery by European Wrist Arthroscopy Society (EWAS) classification. Results The mean follow-up period was 20.2 months (range, 12–41). Preoperatively, positive Watson's test was noted in all cases. DISI deformity was noted in three cases without any SL gap. The SL instability was graded EWAS IIIB (n = 8) or EWAS IIIC (n = 7). Postoperatively, positive Watson's test was noted in only one case. Activity pain decreased from 7.8 preoperatively to 2.4 postoperatively. Range of motion in flexion–extension increased from 92.9 degrees preoperatively to 126.2 degrees postoperatively. Grip strength increased from 24.2 preoperatively to 38.2 postoperatively. At final follow-up, range of motion in flexion–extension and grip strength were estimated at 87 and 91% compared with contralateral side, respectively. All functional scores were significantly improved at the last follow-up. No radiographic SL gapping in grip views or DISI deformity was noted. Discussion Cadaveric studies demonstrated that the dorsal portion of SL ligament is critical for the stability of the SL complex. The entire arthroscopic SL capsuloplasty technique provides reliable results for pain relief, avoiding postoperative stiffness associated with open procedures. It is an alternative technique for patients with predynamic SL instability after failure of medical management and shall not prelude the resort to any further open procedure. Level of Evidence This is a level IV, case series.


2019 ◽  
Vol 48 (2) ◽  
pp. 481-487
Author(s):  
Justin M. Chan ◽  
John Zajac ◽  
Brandon J. Erickson ◽  
David W. Altchek ◽  
Christopher Camp ◽  
...  

Background: Loss of upper and lower extremity range of motion (ROM) is a significant risk factor for injuries in professional baseball players. Purpose/Hypothesis: The purpose was to determine changes in ROM in professional baseball players over the course of a single season and their careers. We hypothesized that pitchers and position players would lose ROM, specifically total shoulder motion (total ROM [TROM]) and hip internal rotation (IR), over the course of a season and their careers. Study Design: Case series; Level of evidence, 4. Methods: Upper and lower extremity ROM measurements were recorded during pre-, mid-, and postseason on all professional baseball players for a single organization between 2011 and 2018. ROM measurements were compared for pitchers and position players over the course of the season and their careers. Also, ROM measurements over the pre-, mid-, and postseason were compared between pitchers and position players. Results: A total of 166 professional baseball players (98 pitchers, 68 position players) were included. Pitcher hip external rotation (ER; P < .001), IR ( P = .010), and TROM ( P < .001) for lead and trail legs decreased over the course of the season. Pitcher shoulder ER ( P = .005), TROM ( P = .042), and horizontal adduction ( P < .001) significantly increased over the course of the season. Position player shoulder flexion ( P = .046), hip ER ( P < .001, lead leg; P < .001, trail leg), and hip TROM ( P = .001; P = .002) decreased over the course of the season. Position player shoulder ER ( P = .031) and humeral adduction ( P < .001) significantly increased over the course of the season. Over the course of pitchers’ careers, there was decreased shoulder IR ( P = .014), increased shoulder horizontal adduction ( P < .001), and hip IR ( P = .042) and hip TROM ( P = .027) for the lead leg. Position players experienced loss of hip TROM ( P = .010, lead leg; P = .018, trail leg) over the course of their careers. Pitchers started with and maintained more shoulder ER and gained more shoulder TROM over a season as compared with position players. Conclusion: Pitchers and position players saw overall decreases in hip ROM but increases in shoulder ROM over the course of the season and career.


2019 ◽  
Vol 40 (8) ◽  
pp. 948-954
Author(s):  
Noriyuki Kanzaki ◽  
Nobuaki Chinzei ◽  
Tetsuya Yamamoto ◽  
Takahiro Yamashita ◽  
Kazuyuki Ibaraki ◽  
...  

Background: Total ankle arthroplasty (TAA) has been developed to treat patients with end-stage ankle osteoarthritis (OA). However, there is often difficulty in treating complicated pathologies such as ankle OA with subtalar joint OA and severe talar collapse. Therefore, this study aimed to explore the short-term results and complications of TAA with total talar prosthesis, known as combined TAA, as the new techniques to treat such complicated pathology. Methods: We examined postoperative results including ankle range of motion, Japanese Society for Surgery of the Foot (JSSF) scale, and complications. There were 22 patients (15 women), with mean follow-up of 34.9 (range, 24–53 months), and the mean age was 72 (range, 62–80) years. The main indications for combined TAA included osteoarthritis (18 patients), rheumatoid arthritis (3 patients), and talar osteonecrosis with osteoarthritis (one patient). Results: The mean range of motion improved from 4.0 to 14.4 degrees in dorsiflexion and from 23.8 to 32.0 degrees in plantarflexion. The JSSF scale improved from 50.5 to 91.5 points. Prolonged wound healing occurred in 3 patients, and medial malleolus fracture occurred in 4 patients. Conclusion: Combined TAA was a reliable procedure for the treatment of not only ankle OA following avascular necrosis of talus but also of degeneration of both ankle and subtalar joints. Level of Evidence: Level IV, case series.


Author(s):  
Carina Büren ◽  
Abdullah Al Maktary ◽  
Joachim Windolf ◽  
Sebastian V. Gehrmann

Abstract Introduction The range of motion of the carpometacarpal (CMC) joints is difficult to assess in clinical practice. Materials and Methods The purpose of this study was to measure a precise range of motion measurement of the metacarpal arc during maximum palmar flexion of the fifth CMC joint in healthy persons with three different methods: optical, electrogoniometrical, and sonographical. Results The metacarpal arc motion measured with the optical technique was 24.9 degrees (standard deviation [SD]: 6.2 degrees), with the electrogoniometric technique was 24.3 degrees (SD: 3.6 degrees) and with sonography was 25.1 degrees (SD: 3.5 degrees), with no differences between left and right hand for all methods. Conclusion This study shows that different techniques can be used for the measurement of the metacarpal arc motion. With these techniques, it is possible to assess the metacarpal arc in patients with fractures to the CMC joints to evaluate posttraumatic function und rehabilitation progress. This study shows level of evidence as III.


2018 ◽  
Vol 31 (10) ◽  
pp. 1031-1036 ◽  
Author(s):  
Jarret Woodmass ◽  
Thomas Sanders ◽  
Nick Johnson ◽  
Isabella Wu ◽  
Aaron Krych ◽  
...  

AbstractInjury to the posterolateral corner (PLC) of the knee can lead to both varus and rotational instability. Multiple PLC reconstruction techniques have been described, including one-tailed graft (fibula-based constructs) or two-tailed graft (combined fibula- and tibia-based constructs). The purpose of our study was to evaluate the clinical outcomes of anatomical two-tailed graft reconstruction of the PLC in the setting of multiligament knee injuries (MKLIs) with grade III varus instability. Patients were identified through a prospective MLKI database between 2004 and 2013. Patients who received fibular collateral ligament and PLC reconstructions using a two-tailed graft and had a minimum follow-up of 2 years were included. Patients were assessed for clinical laxity grade, range of motion, and functional outcomes using Lysholm and International Knee Documentation Committee (IKDC) scores. Twenty patients (16 male, 4 female) with a mean age of 30.7 (range: 16–52) and a mean follow-up of 52.2 months (range: 24–93 months) were included. Knee dislocation (KD) grades included: 4 KD-1, 10 KD 3-L, 5 KD-4, and 1 KD-5. No patients had isolated PLC injuries. Mean IKDC and Lysholm score were 73.1 ± 25.8 and 78 ± 26, respectively. Mean range of motion was –1.1 to 122.8. In full extension, two patients (10%) had grade 1 laxity to varus stress. In 30 degrees of knee flexion, five (25%) patients had grade 1 laxity, and two (10%) had grade 2 laxity. Anatomical two-tailed PLC reconstruction can reliably restore varus stability when performed on patients with MLKIs and type C posterolateral instability with hyperextension external rotation recurvatum deformity. Satisfactory functional outcome scores were achieved in the majority of patients. This study supports the use of an anatomical two-tailed PLC reconstruction in the multiligament injured knee. The level of evidence is IV, case series.


2009 ◽  
Vol 37 (9) ◽  
pp. 1712-1720 ◽  
Author(s):  
Champ L. Baker ◽  
Randy Mascarenhas ◽  
Alex J. Kline ◽  
Anikar Chhabra ◽  
Mathew W. Pombo ◽  
...  

Background There are few reports in the literature detailing the arthroscopic treatment of multidirectional instability of the shoulder. Hypothesis Arthroscopic management of symptomatic multidirectional instability in an athletic population can successfully return athletes to sports with a high rate of success as determined by patient-reported outcome measures. Study Design Case series; Level of evidence, 4. Methods Forty patients (43 shoulders) with multidirectional instability of the shoulder were treated via arthroscopic means and were evaluated at a mean of 33.5 months postoperatively. The mean patient age was 19.1 years (range, 14-39). There were 24 male patients and 16 female patients. Patients were evaluated with the American Shoulder and Elbow Surgeons and Western Ontario Shoulder Instability scoring systems. Stability, strength, and range of motion were also evaluated with patient-reported scales. Results The mean American Shoulder and Elbow Surgeons score postoperatively was 91.4 of 100 (range, 59.9-100). The mean Western Ontario Shoulder Instability postoperative percentage score was 91.1 of 100 (range, 72.9-100). Ninety-one percent of patients had full or satisfactory range of motion, 98% had normal or slightly decreased strength, and 86% were able to return to their sport with little or no limitation. Conclusion Arthroscopic methods can provide an effective treatment for symptomatic multidirectional instability in an athletic population.


2019 ◽  
Vol 27 (3) ◽  
pp. 141-145
Author(s):  
Felipe Hellmeister Burgos ◽  
João Carlos Nakamoto ◽  
Hugo Alberto Nakamoto ◽  
Fernanda do Carmo Iwase ◽  
Rames Mattar Junior

ABSTRACT Objective: To assess and compare radiographic, tomographic and functional pre and postoperative parameters of patients submitted to treatment of nonunion of the scaphoid waist with locked plate for scaphoid. Methods: This is a case series of scaphoid waist nonunion, operated from March 2017 to March 2018 at the Institute of Orthopedics and Traumatology of HCFMUSP, using the technique of Fisk-Fernandez and osteosynthesis with locked plate for scaphoid APTUS®Hand from Medartis. The patients were submitted to radiographs, computed tomography and functional evaluation by the occupational therapy team in the pre and postoperative periods. Results: There was consolidation of the scaphoid waist nonunion in all cases, improvement in the parameters of carpal alignment in the imaging examinations, but functionally we observed reduction of the range of motion and grip strength in relation to the contralateral limb. Conclusions: The treatment of the scaphoid waist nonunion with locked plate was effective, with a high index of consolidation and improvement of the carpal alignment in the imaging tests, although with a reduction in the range of motion and grip strength in relation to the contralateral limb when evaluated with 12 weeks postoperatively. Level of Evidence IV, Case series.


Sign in / Sign up

Export Citation Format

Share Document