scholarly journals Automated Early Detection of Myelodysplastic Syndrome with Beckman-Coulter DxH 800 Hematologyanalyzer By Using Ten Research Parameters

Blood ◽  
2018 ◽  
Vol 132 (Supplement 1) ◽  
pp. 5509-5509
Author(s):  
Noemie Ravalet ◽  
Frederic Picou ◽  
Martin Gombert ◽  
Amelie Foucault ◽  
Emmanuel Renoult ◽  
...  

Abstract Introduction Moderate anemia affects a substantial fraction of the elderly population and blood smear analysis can help to guide towards a diagnosis of myelodysplastic syndrome (MDS). Nevertheless, in medical laboratories, review of blood smear is realized only if there is quantitative or qualitative flag on the complete blood count (CBC). Consequently, the suspicion of MDS could be delayed because of the absence of systematic blood smear triggering, this smear being crucial to induce the diagnosis process by cytological analysis of bone marrow aspiration. The DxH 800 Hematology Analyzer measures and calculates 126 cytological parameters based on photometry, impedance or light scatter. These parameters regroup 23 standard CBC parameters and 103 unexploited "research parameters". The goal of our study was to create an original mathematical model using "research parameters" to determine a Suspicion Score of MDS which triggers blood smear examination and consequently the process of identification of subclinical patients suffering from MDS. Methods This study compared the 126 parameters measured by the Beckman-Coulter DxH 800 Hematology Analyzer from peripheral blood samples of MDS patients and healthy volunteers. MDS cohort was composed of 101 patients of the university hospital of Tours (9 MDS-SLD, 28 MDS-MLD, 8 MDS-RS-SLD, 8 MDS-RS-MLD, 20 MDS-EB-1, 19 MDS-EB-2, 9 5q-). The cohort of healthy volunteers included 88 aged-matched subjects from HEALTHOX and PLASMYC protocols (ClinicalTrials.gov # NCT02789839 and # NCT02809222, respectively). The "research parameters" contained Research Use Only (RUO) parameters and Cell Population Data (CPD). CPD were composed of 98 parameters measured by Volume Conductivity Scatter (VCS) module. The parameters derived from reticulocytes, which require a specific prescription, were excluded. Statistical analyses were performed using Rstudio version 1.0.153. The normal distribution of values was studied by Shapiro-Wilk tests (p-value<0.05) and the homoscedasticity by Levene tests (p-value>0.05). Means comparisons were performed by Wilcoxon and Student tests. Principal component analysis (PCA) was performed using FactoMineR. The logarithmic logistic regression was done thanks to the glm() function of the stats package. The general linear model was obtained by using logistic regression with weighted parameters and was validated by split-sample strategy (10,000 repeats). Samples were divided into two groups ("learning" and "test" groups) randomly mixing MDS patients and healthy volunteers. The "learning" group (n=130) allowed to build the model and the "test" group (n=59) was used to validate it. Results After mono-parametric and multi-parametric comparisons, 10 parameters were selected to establish the model of interest according to the best contributions at the first axe of PCA, the best correlations at two first axes of PCA and the most significant p-values (parameters described in the Table: MN.LALS.NNRBC, MN.LMALS.NNRBC, MN.UMALS.NNRBC, SD.MALS.NE, SD.UMALS.NE, SD.V.NE, MN.MALS.NE, SD.AL2.NE, SD.AL2.MO, SD.V.MO ). In order to determine the Suspicion Score of MDS (SS-MDS), the 10 selected parameters were weighted during split sampling strategy by logistic regression. After repeat of 10,000 split-samples, the SS-MDS determined using weighted parameters was validated with average efficiency of 92.3%. For each parameter, the median of weighting coefficients was used in the mathematical model: "SS-MDS = ΣCi.Pi + intercept" with "Ci: weighting coefficient of parameter i" and "Pi: parameter i value". On the whole cohort, SS-MDS induced "MDS" flag for 11 MDS patients (red points in the Figures) for which conventional CBC algorithms failed to generate flag spreading peripheral blood smear. By fixing the threshold at -1.5, the sensitivity and specificity of SS-MDS were 100% and 92%, respectively. Moreover, the positive and negative predictive values were 93.5% and 100%, respectively. Conclusions The incidence of MDS increases with aging and the early diagnosis enables optimal care of these diseases. The Beckman-Coulter DxH 800 HematologyAnalyzer is widely used over the world. We propose in this study the clinical use of 10 unexploited "research parameters" to early detect subclinical MDS by selective triggering of blood smear examination. A prospective/multicentric study will allow the optimization of SS-MDS. Figure. Figure. Disclosures No relevant conflicts of interest to declare.

2021 ◽  
Vol 28 (10) ◽  
pp. 1433-1437
Author(s):  
Rabiah Asghar ◽  
Javera Tariq ◽  
Nabeela Naeem ◽  
Anila Zafar ◽  
Khadija Qureshi ◽  
...  

Objective: This study aims to determine diagnostic accuracy of peripheral blood smear and automated haematology analyzer and to determine frequency of different types of anemia diagnosed by peripheral blood smear and automated hematology analyzer. Study Design: Cross Sectional study. Setting: Department of Pathology, Rawal Institute of Health Sciences, Islamabad. Period: November 2015 to April 2016. Material & Methods: Sample size of 149 suspected anemia patients was calculated using WHO calculator with 95% confidence interval. Research approval was taken from hospital ethical board. Patients were approached through non probability consecutive sampling method. Both peripheral blood smear examination and automated haematology analysis of each sample was performed. Diagnostic accuracy and frequency of anemia types was measured. Data analysis was done with the help of SPSS version 25. Chi-square and fissure exact test and ROC curve analysis was applied and significant (p<0.05) results were reported. Results: Total 149 patients were included in study. There were 42(28.2%) male and 107(71.8%) female.  Mean age of patients was 35.1±2.1SD. Peripheral blood smear and automated haematology analyzer showed sensitivity (68% vs 92%), specificity (59% vs 88%), PPV (72% vs 92%), NPV (55% vs 88%) and diagnostic accuracy (64% vs 91) respectively. Most common type of anemia diagnosed with peripheral blood smear was microcytic hypochromic anemia with raised RDW 36.7% followed by normocytic normochromic anemia with raised RDW 13.3% and macrocytic anemia (p=0.001) while in automated haematology analyzer microc ytic hypochromic anemia with raised RDW54.4% followed by normochromic normocytic anemoia with normal RDW 11.1% (p=0.000). Conclusion: Automated haematyology analyzer had high diagnostic accuracy for diagnosis of anemia.  Microcytic hypochromic anemia and normocytic normochromic are most common anemias diagnosed by peripheral blood smear and automated hematology analyzer and peripheral blood smear cannot be completely replaced by automated haemolytic analyzer. However, if both methods are used simultaneously, more accurate results can be obtained.


Biomedika ◽  
2020 ◽  
Vol 13 (1) ◽  
pp. 83-91
Author(s):  
Alex Jekson Tukira ◽  
Lucia Sincu Gunawan ◽  
Edy Prasetya

Anemia is a decrease in the number of erythrocytes in the blood circulation or the level of hemoglobin that is less than normal. The three major body mechanisms that cause anemia are excessive destruction of erythrocytes, blood loss, and decreased erythrocyte production. Based on the Basic Health Research (Riskesdas) in 2013, the prevalence of anemic women of reproductive age (WORA) aged 15-44 years in Indonesia was 35.3%. Anemia is classified based on the morphology of erythrocytes, including hypochromic microcytic, normocytic normochromic, and macrocytic. Erythrocyte morphology can be observed using peripheral blood smear examination. The objective of this study was to determine the morphology of erythrocytes in anemic women of reproductive age. This study belongs to descriptive research. The population of the study was 136 women of reproductive age, covering the students of D-IV in Medical Laboratory Technology at Setia Budi University. Forty-one respondents suffering from anemia were taken using a purposive sampling technique. The types of anemia were determined with examination using an Easy Touch hemoglobinometer with the Hb level of less than 12g/dL. Preparation of peripheral blood smear examination using EDTA venous blood and stained with Giemsa. Microscopic examination was performed with 1000x objective magnification. The peripheral blood smear reading showed the erythrocyte morphology that includes normocytic normochromic (38 samples or 93%), microcytic hypochromic (three samples or 7%), and poikilocytosis consisting of teardrop cells, target cells, ellipstocytes, and stomatocytes (five samples or 18%). Further study is required to investigate the correlation of erythrocyte index and peripheral blood smear in anemia.