Idarucizumab Fully Restores Dabigatran-Induced Alterations on Platelet and Fibrin Deposition on Damaged Vessels: Studies in Vitro with Circulating Human Blood

Blood ◽  
2014 ◽  
Vol 124 (21) ◽  
pp. 2878-2878 ◽  
Author(s):  
Eduardo Arellano-Rodrigo ◽  
Irene Lopez-Vilchez ◽  
Patricia Molina ◽  
Marcos Pino ◽  
Maribel Diaz-Ricart ◽  
...  

Abstract BACKGROUND: Despite the proven efficacy and safety profile of dabigatran as compared to warfarin, bleeding remains a concern as with all anticoagulants and the reversal of dabigatran’s anticoagulant effect for emergency procedures remains controversial. Recently, idarucizumab, a specific antidote for dabigatran, has been functionally characterized and its efficacy demonstrated in animal models and healthy volunteer studies. AIMS: We explored the effects of dabigatran on hemostasis in human blood focusing on possible interference with platelet and coagulation responses to vessel injury under flow conditions. We also compared the potential efficacy of idarucizumab with procoagulant strategies such as prothrombin complex concentrates (PCC), activated PCC (aPCC) or rFVIIa at reversing the antithrombotic action of dabigatran to better understand local processes in response to injury. METHODS: Concentrations of dabigatran equivalent to the Cmax reported at steady state after therapy with 150 mg twice daily (184 ng/mL) were added in vitro to blood aliquots from 11 healthy donors. Whole blood samples were used to evaluate modifications in different coagulation biomarkers: 1) fibrin and platelet deposition on damaged vascular segments with whole blood under flow conditions at a shear rate of 600 s-1, 2) dynamics of thrombin generation (TG) in plasma using a fluorogenic assay (Technothrombin TGA) and 3) viscoelastic parameters of clot formation in whole blood using by thromboelastometry (ROTEM) The efficacy of specific reversal with idarucizumab 0.3, 1 and 3 mg/mL was compared with that of non specific procoagulant concentrates such as aPCC 25 and 75 IU/kg, PCC 70 IU/kg, or rFVIIa 120 µg/kg. RESULTS: Dabigatran (184 ng/mL) caused a pronounced 85% reduction of fibrin coverage on the damaged vessel from 67.2±9.8 to 9.5±1.3 % (p<0.01) and a moderate 35% reduction of platelet deposition from 25.9±2.7 to 16.9±2.9 % (p<0.01). Dabigatran also altered dynamics of TG with a prolongation of the lag-phase and a reductions in the maximal thrombin peak and potential of thrombin generation (p<0.01). In ROTEM, dabigatran significantly prolonged clotting time to 352±60 sec (p<0.01) and clot formation time to 312±76 sec (p<0.05). Idarucizumab completely reversed the alterations in all different biomarkers induced by dabigatran. Additionally, fibrin coverage and platelet deposition were restored to baseline values in flow studies. TG and ROTEM parameters also returned to normal values after idarucizumab. Reversal strategies with aPCC or PCC normalized and even over-compensated alterations in TG kinetics and partially improved alterations in ROTEM parameters caused by dabigatran. Interestingly, aPCC and PCC moderately improved the alteration in fibrin deposition caused by dabigatran in flow studies (15.7±8.2, 29.3±14.5, and 15.2±3.7 %, respectively for aPCCs 25, 75 or PCCs 70 IU/kg). However, levels of fibrin formation did not return to baseline values before dabigatran (67.2±32.5 %). rFVIIa showed only moderate effects on some of the biomarkers evaluated, though values were never restored to the baseline. CONCLUSIONS: Dabigatran (184 ng/mL) added to blood from healthy volunteers caused evident alterations in hemostasis parameters related to its recognized anticoagulant action. Procoagulant concentrates significantly compensated for the overall anti-hemostastic action of dabigatran. Overall, 75 U/kg aPCC seemed the more efficient nonspecific reversal therapy. In clear contrast with non specific procoagulant strategies, idarucizumab, the specific antidote to dabigatran completely reversed all alterations in coagulation parameters evaluated in circulating human blood and in assay systems. (Supported by SAF 2011-2814 and PI13/00517, Spanish Gov & FEDER) Disclosures van Ryn: Boehringer Ingelheim Pharma: Employment. Escolar:Boehringer Ingelheim Pharma: Investigator Sponsored Research Funding Other.

Blood ◽  
2018 ◽  
Vol 132 (Supplement 1) ◽  
pp. 1253-1253
Author(s):  
Marco Khiella ◽  
Walter Jeske ◽  
Jeanine Walenga ◽  
Omer Iqbal ◽  
Rajan Laddu ◽  
...  

Abstract Introduction: Heparin prevents blood clots from forming in patients undergoing heart surgeries, dialysis, multiple other procedures, and for medical treatment of thrombosis such as associated with cancer. Currently, all heparin products in the U.S. are derived from the intestinal mucosa of pigs. Seventy-five percent of the crude porcine heparin used to make the active pharmaceutical ingredient (API) comes from outside the U.S., with a majority originating from China. Reintroduction of bovine heparin into the U.S. market would expand sources for this critical drug, thus addressing concerns about potential shortages and product adulteration. This study was undertaken to determine the bioequivalence of bovine and porcine heparins using assays relevant to the clinical setting. The assays used in this study were chosen because they overcome limitations of the conventional APTT for heparin monitoring. Selected TEG and ACT assays use whole blood which better simulates physiologic conditions and assesses the full in vitro anticoagulation potential of heparin; these assays are also routinely used clinically for heparin monitoring. The thrombin generation assay is state-of-the-art for hemostatic clinical lab testing, and it provides a more sensitive endpoint of the final generation of thrombin once coagulation is activated. Heparins were studied at concentrations used clinically and tested by assays sensitive to these concentrations. Methods: Bovine heparin API (BH; 7 lots) and US clinical grade porcine heparin (PH: 3 lots) were tested in parallel using recalcified whole blood thromboelastography (TEG; Haemonetics), celite activated clotting time (ACT; Hemochron), and thrombin generation (TGA; Diapharma). Fresh blood was obtained from healthy volunteers under an IRB approved protocol (n=6 per group). Previous work from our lab (Jeske W, Thrombosis & Hemostasis Societies of North America, P57, 2018) identified a weaker potency of BH than PH when compared on an equigravimetric basis in pharmacopeial assays; however, equivalent potency could be obtained when BH was standardized against PH on a unitage basis. In this study, heparins were studied on both a gravimetric and a unitage basis for a comprehensive evaluation. The potency of the BH was determined by pharmacopeial compliant anti-Xa and anti-IIa chromogenic assays cross-referenced to the porcine USP Heparin Reference Standard. Results: All results are depicted in Table 1. For the TEG, the R value, time of latency from start to initial fibrin formation, and the K value, time to achieve a defined clot strength due to thrombin generation and platelet activation, bovine heparin and porcine heparin did not demonstrate a significant difference in anticoagulant activity. The TEG angle, a measure of the speed of fibrin build-up and cross-linking (clot strengthening or rate of clot formation), and the maximum amplitude (MA) value, a function of the maximum of fibrin and platelet binding representing the strongest point of fibrin clot formation, also revealed no significant difference between bovine and porcine heparin anticoagulant activity. For the ACT, at concentrations of 10 µg/mL and 25 µg/mL, there were no statistically significant differences between BH and PH. For the TGA, measuring the time delay until the initiation of thrombin generation following tissue factor (TF) activation, the highest amount of thrombin generated after TF activation, and the total amount of thrombin generated after TF activation (AUC), showed a trend that PH was more potent than BH, but wide variation in the results did not allow for statistical differences to be identified. Conclusion: The results of this investigation demonstrate that bovine heparin produces an equivalent anticoagulant activity as porcine heparin in the TEG, ACT, and TGA assay systems. The equivalent ACT results, in particular, were unexpected since gravimetric amounts of heparins were evaluated. As for all heparins, standardization of bovine heparin in accordance with the process used for porcine heparin will assure equivalent anticoagulant activity among bovine and porcine heparins in whole blood, plasma-based, and pharmacopeial assays. This study further demonstrates that the current assays used to monitor porcine heparin can be similarly used to monitor bovine heparin. Disclosures Walenga: Eurofarma: Research Funding.


2014 ◽  
Vol 111 (03) ◽  
pp. 447-457 ◽  
Author(s):  
Marisa Ninivaggi ◽  
Gerhardus Kuiper ◽  
Marco Marcus ◽  
Hugo ten Cate ◽  
Marcus Lancé ◽  
...  

SummaryBlood dilution after transfusion fluids leads to diminished coagulant activity monitored by rotational thromboelastometry, assessing elastic fibrin clot formation, or by thrombin generation testing. We aimed to determine the contributions of blood cells (platelets, red blood cells) and plasma factors (fibrinogen, prothrombin complex concentrate) to fibrin clot formation under conditions of haemodilution in vitro or in vivo. Whole blood or plasma diluted in vitro was supplemented with platelets, red cells, fibrinogen or prothrombin complex concentrate (PCC). Thromboelastometry was measured in whole blood as well as plasma; thrombin generation was determined in parallel. Similar tests were performed with blood from 48 patients, obtained before and after massive fluid infusion during cardiothoracic surgery. Addition of platelets or fibrinogen, in additive and independent ways, reversed the impaired fibrin clot formation (thromboelastometry) in diluted whole blood. In contrast, supplementation of red blood cells or prothrombin complex concentrate was ineffective. Platelets and fibrinogen independently restored clot formation in diluted plasma, resulting in thromboelastometry curves approaching those in whole blood. In whole blood from patients undergoing dilution during surgery, elastic clot formation was determined by both the platelet count and the fibrinogen level. Thrombin generation in diluted (patient) plasma was not changed by fibrinogen, but improved markedly by prothrombin complex concentrate. In conclusion, in dilutional coagulopathy, platelets and fibrinogen, but not red blood cells or vitamin K-dependent coagulation factors, independently determine thromboelastometry parameters measured in whole blood and plasma. Clinical decisions for transfusion based on thromboelastometry should take into account the platelet concentration.


1992 ◽  
Vol 20 (3) ◽  
pp. 390-395 ◽  
Author(s):  
Thomas Groth ◽  
Katrin Derdau ◽  
Frank Strietzel ◽  
Frank Foerster ◽  
Hartmut Wolf

Twenty years ago Imai & Nose introduced a whole-blood clotting test for the estimation of haemocompatibility of biomaterials in vitro In our paper a modification of this assay is described and the mechanism of clot formation further elucidated. It was found that neither the inhibition of platelet function nor the removal of platelets from blood significantly changed the clot formation rate on glass and polyvinyl chloride in comparison to the rate tor whole blood. Scanning electron microscopy demonstrated that platelets were not involved in clot formation near the blood/biomaterial interface. Thus, it was concluded that the system of contact activation of the coagulation cascade dominates during clot formation under static conditions. The latter conclusion was supported by the fact that preadsorption of human serum albumin or human fibrinogen onto the glass plates used, decreased the clot formation rate in the same manner.


1991 ◽  
Vol 65 (5) ◽  
pp. 589-596 ◽  
Author(s):  
B. Kaiser ◽  
J. Fareed ◽  
J.M. Walenga ◽  
D. Hoppensteadt ◽  
F. Markwardt

2004 ◽  
Vol 15 (2) ◽  
pp. 149-156 ◽  
Author(s):  
Grigoris T Gerotziafas ◽  
François Depasse ◽  
Tahar Chakroun ◽  
Patrick Van Dreden ◽  
Meyer M Samama ◽  
...  

2017 ◽  
Vol 23 (3) ◽  
pp. 607-617 ◽  
Author(s):  
Albe C. Swanepoel ◽  
Odette Emmerson ◽  
Etheresia Pretorius

AbstractCombined oral contraceptive (COC) use is a risk factor for venous thrombosis (VT) and related to the specific type of progestin used. VT is accompanied by inflammation and pathophysiological clot formation, that includes aberrant erythrocytes and fibrin(ogen) interactions. In this paper, we aim to determine the influence of progesterone and different synthetic progestins found in COCs on the viscoelasticity of whole blood clots, as well as erythrocyte morphology and membrane ultrastructure, in an in vitro laboratory study. Thromboelastography (TEG), light microscopy, and scanning electron microscopy were our chosen methods. Our results point out that progestins influence the rate of whole blood clot formation. Alterations to erythrocyte morphology and membrane ultrastructure suggest the presence of eryptosis. We also note increased rouleaux formation, erythrocyte aggregation, and spontaneous fibrin formation in whole blood which may explain the increased risk of VT associated with COC use. Although not all COC users will experience a thrombotic event, individuals with a thrombotic predisposition, due to inflammatory or hematological illness, should be closely monitored to prevent pathological thrombosis.


2014 ◽  
Vol 2014 ◽  
pp. 1-7
Author(s):  
Louise Ann Clark ◽  
Jochen Beyer ◽  
Andis Graudins

Background. Intravenous lipid emulsion (ILE) is recommended as a “rescue” treatment for local anaesthetic (LA) toxicity. A purported mechanism of action suggests that lipophilic LAs are sequestered into an intravascular “lipid-sink,” thus reducing free drug concentration. There is limited data available correlating the effects of ILE on LAs.Aims. To compare the in vitro effect of ILE on LA concentrations in human blood/plasma and to correlate this reduction to LA lipophilicity.Method. One of four LAs (bupivacaine-most lipophilic-4 mg/L, ropivacaine-6 mg/L, lignocaine-14 mg/L, and prilocaine-least lipophilic-7 mg/L) was spiked into plasma or whole blood. ILE or control-buffer was added. Plasma was centrifuged to separate ILE and total-LA concentration assayed from the lipid-free fraction. Whole blood underwent equilibrium dialysis and free-LA concentration was measured. Percent reduction in LA concentration from control was compared between the LAs and correlated with lipophilicity.Results. ILE caused a significant reduction in total and free bupivacaine concentration compared with the other LAs. Ropivacaine had the least reduction in concentration, despite a lipophilicity similar to bupivacaine. The reduction in LA concentration correlated to increasing lipophilicity when ropivacaine was excluded from analysis.Conclusion. In this first in vitro model assessing both free- and total-LA concentrations exposed to ILE in human blood/plasma, ILE effect was linearly correlated with increasing lipophilicity for all but ropivacaine.


2009 ◽  
Vol 109 (4) ◽  
pp. 1023-1028 ◽  
Author(s):  
Csilla Jámbor ◽  
Viviane Reul ◽  
Thomas W. Schnider ◽  
Priska Degiacomi ◽  
Hubert Metzner ◽  
...  

Blood ◽  
2010 ◽  
Vol 116 (21) ◽  
pp. 5129-5129
Author(s):  
Jawed Fareed ◽  
Debra Hoppensteadt ◽  
Omer Iqbal ◽  
Jeanine M. Walenga ◽  
Bruce E Lewis

Abstract Abstract 5129 Several generic versions of argatroban) (Mitsubishi; Tokyo, Japan) have been introduced in Japan (Argaron, Gartban, Slovastan). In addition, other generic versions of argatroban are being considered by the European and North American regulatory bodies. While the generic versions of argatroban exhibit similar antithrombin potency (Ki values), because of the differential compositional variations their anticoagulant effects in whole blood systems may differ due to their cellular and plasmatic protein interactions. Branded and generic versions of argatroban may exhibit differential anticoagulant actions in the whole blood and plasma based assays due to their differential interactions with blood cells, platelets and plasma proteins. Three generic versions of argatroban that are commercially available in Japan namely Argaron, Gartban and Slovastan and a powdered version of generic argatroban (Lundbeck) were compared with the branded argatroban. Native whole blood thrombelastographic (TEG) analysis was carried out at 0.1 ug/mL, the Activated Clotting Time (ACT) assay was carried out in a concentration range of 0–10 ug/mL, and such coagulation tests as the PT/INR, aPTT, Heptest, and calcium thrombin time were performed. Plasma retrieved from the supplemented whole blood was also assayed. Ratios of the clotting time test values from whole blood and plasma were calculated. Retrieved plasma samples were also assayed in the thrombin generation assays (TGA). All of the different versions of argatroban produced a concentration dependent anticoagulant effect in the native whole blood TEG and ACT. In the TEG, while argatroban and Slovastan showed a similar effect, Gartban, Argaron and a powdered generic showed weaker effects. Argatroban was also different in the ACT assay. At a concentration of 5 ug/ml the ACTs were, Arg 340+15.2 secs, S 297+10.5 secs, G 292.0+19.1 secs and A 285.2+21.7 secs. In the citrated whole blood systems, all agents produced a concentration dependent anticoagulant effect; however, the generic versions produced a stronger anticoagulant effect in comparison to branded argatroban (p<0.001). In the PT assay at 5 ug/mL, argatroban showed 32 ± 3 sec vs 40–50 sec for the generic products. Similarly in the aPTT, Heptest and thrombin time tests argatroban was weaker than the generic products. Differences among generic versions were also evident. Similar results were obtained in the retrieved plasma, however the ratio of whole blood over plasma varied from product to product. The IC50 of the generic and branded argatrobans in the TGA were also different. These results show that while in the thrombin inhibition assays generic and branded argatroban may show similar effects, these agents exhibit assay dependent differences in the whole blood and plasma based assays. Such differences may be more evident in the in vivo studirs where endothelial cells and other interactions may contribute to product individuality. Therefore, based on the in vitro antiprotease assays, generic argatrobans may not be considered equivalent and require a multi-parametric study. Currently available generic argatrobans may not be equivalent in the in vivo anticoagulant effects. Therefore, clinical validation of the clinical equivalence for these drugs is warranted. Disclosures: No relevant conflicts of interest to declare.


Sign in / Sign up

Export Citation Format

Share Document