scholarly journals Real-Time PCR for detection of herpes simplex virus without nucleic acid extraction

2006 ◽  
Vol 6 (1) ◽  
Author(s):  
Mark W Pandori ◽  
John Lei ◽  
Ernest H Wong ◽  
Jeffrey Klausner ◽  
Sally Liska
Pathogens ◽  
2021 ◽  
Vol 10 (2) ◽  
pp. 188
Author(s):  
Tanja Hoffmann ◽  
Andreas Hahn ◽  
Jaco J. Verweij ◽  
Gérard Leboulle ◽  
Olfert Landt ◽  
...  

This study aimed to assess standard and harsher nucleic acid extraction schemes for diagnostic helminth real-time PCR approaches from stool samples. A standard procedure for nucleic acid extraction from stool and a procedure including bead-beating as well as proteinase K digestion were compared with group-, genus-, and species-specific real-time PCR assays targeting helminths and nonhelminth pathogens in human stool samples. From 25 different in-house and commercial helminth real-time PCR assays applied to 77 stool samples comprising 67 historic samples and 10 external quality assessment scheme samples positively tested for helminths, higher numbers of positive test results were observed after bead-beating-based nucleic acid extraction for 5/25 (20%) real-time PCR assays irrespective of specificity issues. Lower cycle threshold values were observed for one real-time PCR assay after the standard extraction scheme, and for four assays after the bead-beating-based scheme. Agreement between real-time PCR results after both nucleic acid extraction strategies according to Cohen’s kappa ranged from poor to almost perfect for the different assays. Varying agreement was observed in eight nonhelminth real-time PCR assays applied to 67 historic stool samples. The study indicates highly variable effects of harsh nucleic acid extraction approaches depending on the real-time PCR assay used.


2011 ◽  
Vol 50 (3) ◽  
pp. 948-952 ◽  
Author(s):  
J.-F. Jazeron ◽  
C. Barbe ◽  
E. Frobert ◽  
F. Renois ◽  
D. Talmud ◽  
...  

2021 ◽  
Author(s):  
Sayantan Tripathy ◽  
Arunansu Talukdar ◽  
Goutam Pramanik ◽  
P. V. Rajesh ◽  
Souradyuti Ghosh

<b>Layman Summary: </b>Nucleic acid extraction is a key prerequisite for any nucleic acid amplification test (NAAT) or isothermal NAAT (iNAAT) based molecular diagnosis assays.<b> </b>Existing methods utilizes spin column system for nucleic acid extraction which are unsuitable for limited resource settings. Our work explores two methods for chitosan coated magnetic particle preparation that can be executed within 6 h from commonly available chemicals with nothing but a magnetic stirrer and water bath and doable by a minimally trained person. We will also investigated the compatibility of the extracted nucleic acid with downstream NAATs such as real time LAMP, colorimetric LAMP, and real time PCR. In the process, we established the analytical sensitivity of the overall method.<div><br><div><b>Characterization methods</b>: SEM, XRD, EDX, FT-IR</div><div><br></div><div><b>Bioanalytical methods:</b> Real time LAMP, Colorimetric LAMP, Real time PCR</div></div>


1999 ◽  
Vol 37 (6) ◽  
pp. 1941-1947 ◽  
Author(s):  
Alexander J. Ryncarz ◽  
James Goddard ◽  
Anna Wald ◽  
Meei-Li Huang ◽  
Bernard Roizman ◽  
...  

We have developed a high-throughput, semiautomated, quantitative fluorescence-based PCR assay to detect and type herpes simplex virus (HSV) DNA in clinical samples. The detection assay, which uses primers to the type-common region of HSV glycoprotein B (gB), was linear from <10 to 108 copies of HSV DNA/20 μl of sample. Among duplicate samples in reproducibility runs, the assay showed less than 5% variability. We compared the fluorescence-based PCR assay with culture and gel-based liquid hybridization system with 335 genital tract specimens from HSV type 2 (HSV-2)-seropositive persons attending a research clinic and 380 consecutive cerebrospinal fluid (CSF) samples submitted to a diagnostic virology laboratory. Among the 162 culture-positive genital tract specimens, TaqMan PCR was positive for 157 (97%) specimens, whereas the quantitative-competitive PCR was positive for 144 (89%) specimens. Comparisons of the mean titer of HSV DNA detected by the two assays revealed that the mean titer detected by the gel-based system was slightly higher (median, 1 log). These differences in titers were in part related to the fivefold difference in the amount of HSV DNA used in the amplicon standards with the two assays. Among the 380 CSF samples, 42 were positive by both assays, 13 were positive only by the assay with the agarose gel, and 3 were positive only by the assay with the fluorescent probe. To define the subtype of HSV DNA detected in the screening assay, we also designed one set of primers which amplifies the gG regions of both types of HSV and probes which are specific to either HSV-1 (gG1) or HSV-2 (gG2). These probes were labeled with different fluorescent dyes (6-carboxyfluorescein for gG2 and 6-hexachlorofluorescein for gG1) to enable detection in a single PCR. In mixing experiments the probes discriminated the correct subtype in mixtures with up to a 7-log-higher concentration of the opposite subtype. The PCR typing results showed 100% concordance with the results obtained by assays with monoclonal antibodies against HSV-1 or HSV-2. Thus, while the real-time PCR is slightly less sensitive than the gel-based liquid hybridization system, the high throughput, the lack of contamination during processing, the better reproducibility, and the better ability to type the isolates rapidly make the real-time PCR a valuable tool for clinical investigation and diagnosis of HSV infection.


Sign in / Sign up

Export Citation Format

Share Document