scholarly journals Myocardial iron quantification using modified Look-Locker inversion recovery (MOLLI) T1 mapping at 3 Tesla

Author(s):  
GC Camargo ◽  
T Rothstein ◽  
FP Junqueira ◽  
E Fernandes ◽  
RL Lima ◽  
...  
2013 ◽  
Vol 15 (S1) ◽  
Author(s):  
Gabriel C Camargo ◽  
Tamara Rothstein ◽  
Flavia P Junqueira ◽  
Peter Kellman ◽  
Andreas Greiser ◽  
...  

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
D. Kuetting ◽  
J. Luetkens ◽  
A. Faron ◽  
A. Isaak ◽  
U. Attenberger ◽  
...  

AbstractOur aim was to investigate the diagnostic yield of rapid T1-mapping for the differentiation of malignant and non-malignant effusions in an ex-vivo set up. T1-mapping was performed with a fast modified Look-Locker inversion-recovery (MOLLI) acquisition and a combined turbo spin-echo and inversion-recovery sequence (TMIX) as reference. A total of 13 titrated albumin-solutions as well as 48 samples (29 ascites/pleural effusions from patients with malignancy; 19 from patients without malignancy) were examined. Samples were classified as malignant-positive histology, malignant-negative histology and non-malignant negative histology. In phantom analysis both mapping techniques correlated with albumin-content (MOLLI: r = − 0.97, TMIX: r = − 0.98). MOLLI T1 relaxation times were shorter in malignancy-positive histology fluids (2237 ± 137 ms) than in malignancy-negative histology fluids (2423 ± 357 ms) as well as than in non-malignant-negative histology fluids (2651 ± 139 ms); post hoc test for all intergroup comparisons: < 0.05. ROC analysis for differentiation between malignant and non-malignant effusions (malignant positive histology vs. all other) showed an (AUC) of 0.89 (95% CI 0.77–0.96). T1 mapping allows for non-invasive differentiation of malignant and non-malignant effusions in an ex-vivo set up.


2013 ◽  
Vol 15 (S1) ◽  
Author(s):  
Fabio S Raman ◽  
Nadine Kawel ◽  
Neville Gai ◽  
Melanie Freed ◽  
Jing Han ◽  
...  

Blood ◽  
2020 ◽  
Vol 136 (Supplement 1) ◽  
pp. 26-27
Author(s):  
Alessia Pepe ◽  
Nicola Martini ◽  
Antonio De Luca ◽  
Vincenzo Positano ◽  
Laura Pistoia ◽  
...  

Background.Cardiovascular magnetic resonance (CMR) is the only available technique for the non-invasive quantification of MIO. The native T1 mapping has recently been proposed as an alternative to the universally adopted T2* technique, due to the higher sensitivity for detection of changes associated with mild or early iron overload. Objective.To study the association between T1 values and left ventricular (LV) function in thalassemia major (TM) and to evaluate for the first time if T1 measurements quantifying MIO are influenced by macroscopic myocardial fibrosis. Methods.146 TM patients (87 females, 38.7±11.1 years) consecutively enrolled in the Extension-Myocardial Iron Overload in Thalassemia Network underwent CMR. Native T1 values were obtained by Modified Look-Locker Inversion recovery (MOLLI) sequence in all 16 myocardial segments and the global value was the mean. LV function parameters were quantified by cine images. Late gadolinium enhancement (LGE) technique was used to detect macroscopic myocardial fibrosis. Results.No correlation was detected between global heart T1 values and LV volume indexes, LV mass index, or LV ejection fraction. Foourteen (9.6%) patients had an abnormal LV motion (13 hypokinesia and 1 dyskinesia) and they showed significantly lower global heart T1 values than patients without LV motion abnormalities (883.8±139.7 ms vs 959.0±91.3 ms; P=0.049). LGE images were acquired in 88 patients (60.3%) and macroscopic myocardial fibrosis was detected in 36 patients (40.9%). The 72.2% of patients had two or more foci of fibrosis. Patients with macroscopic myocardial fibrosis had significantly lower global heart T1 values (921.3±100.3 ms vs 974.5±72.7 ms; P=0.027) (Figure 1A). Data about the LGE was present for 1408 segments (88 patients x 16 segments) and 105 (7.5%) were positive. Segments with LGE had significantly lower T1 values than segments LGE-negative (905.6±110.6 ms vs 956.9±103.8 ms; P&lt;0.0001) (Figure 1B). Conclusion.No correlation between T1 values and LV function parameters was detected, probably because the majority of the patients had normal or mild abnormal LV parameters. TM patients with macroscopic myocardial fibrosis showed significantly lower T1 values suggesting that T1 measurements for quantifying MIO are not influenced by macroscopic myocardial fibrosis and an association between myocardial iron and macroscopic fibrosis, previously detected only in pediatric TM patients. Figure Disclosures Pepe: Chiesi Farmaceutici S.p.A.:Other: no profit support and speakers' honoraria;Bayer:Other: no profit support;ApoPharma Inc.:Other: no profit support.Pistoia:Chiesi Farmaceutici S.p.A.:Other: speakers' honoraria.Meloni:Chiesi Farmaceutici S.p.A.:Other: speakers' honoraria.


Sign in / Sign up

Export Citation Format

Share Document