scholarly journals P187: Harnessing the power of the mind to reduce healthcare associated infections - a cost effective approach in low resource settings

Author(s):  
N Jaggi ◽  
P Nirwan ◽  
E Naryana ◽  
KP Kaur
Author(s):  
Allicia Ostoposides Imada ◽  
James J. O’Hara ◽  
Ignacio L. Proumen ◽  
Pablo S. Molinari ◽  
Daniel C. Wascher ◽  
...  

2017 ◽  
Vol 3 (2_suppl) ◽  
pp. 4s-5s
Author(s):  
Miriam Cremer ◽  
Karla Alfaro ◽  
Mauricio Maza ◽  
Philip E. Castle ◽  
Albert Zevallos ◽  
...  

Abstract 22 Background: Screening followed by treatment has been a key contributor to the reduction of cervical cancer in industrialized countries and is critical to reduce its burden in low-resource countries. Screening technologies that are appropriate for low-resource settings have advanced considerably; however, treatment technologies have lagged. Treatment methods that are used in developing countries must be low cost, effective, and adaptable for areas with limited infrastructure and health care providers. This study was performed to determine the depth of necrosis in cervical tissue achieved with three treatment devices: conventional cryotherapy with CO2, the CryoPen (CryoPen, Corpus Christi, TX) adapted for low-resource settings, and the thermocoagulator. Methods: One hundred twenty-five women who were scheduled for hysterectomy for indications other than cervical pathology were randomly assigned to one of five treatment arms: single-freeze arms and double-freeze arms for both conventional cryotherapy and the adapted CryoPen, and a single application of thermoablation at 100° C for 40 seconds. Treatment was administered 12 to 24 hours before hysterectomy. Depth of necrosis in cervical specimens was measured by pathologists who were blinded to the treatment modality. Results: A total of 119 women have been enrolled to date, and 114 specimens have been reviewed. Mean depth of necrosis is 5.1 mm (0.9 to 8.5 mm) for single-freeze cryotherapy, 5.6 mm (3.8 to 10.5 mm) for double-freeze cryotherapy, 4.9 mm (3.5 to 8.5 mm) for single-freeze adapted CryoPen; 4.5 mm (3.0 to 7.3 mm) for double-freeze adapted CryoPen, and 3.7 mm (1.9 to 5.5 mm) for the thermoablation ( Table 1 ). Conclusion: The depths of necrosis achieved with the three different ablation modalities are competitive and surpass the targeted depth of 3.5 mm established a priori. Results thus far have demonstrated that devices that are optimized for use in low-resource settings can be as effective as conventional cryotherapy in treating cervical intraepithelial neoplasia. [Table: see text] AUTHORS' DISCLOSURES OF POTENTIAL CONFLICTS OF INTEREST Miriam Cremer Honoraria: Merck Speakers' Bureau: Merck Travel, Accommodations, Expenses: Merck Other Relationship: Basic Health International Karla Alfaro No relationship to disclose Mauricio Maza No relationship to disclose Philip E. Castle No relationship to disclose Albert Zevallos No relationship to disclose Ana Cecilia Diaz de Uriarte No relationship to disclose Manuel Alvarez No relationship to disclose Manuel Salinas No relationship to disclose Ana Sofia Ore No relationship to disclose Luis Taxa No relationship to disclose Juan Felix Expert Testimony: Johnson & Johnson, Philip Morris


2019 ◽  
Vol 13 (10) ◽  
pp. 858-864 ◽  
Author(s):  
Gopal Panta ◽  
Ann K Richardson ◽  
Ian C Shaw

Medical devices are sterilized before being used for invasive clinical procedures such as surgery, to prevent pathogen transfer. Failure to sterilize medical devices properly presents a risk of healthcare-associated infections. Studies and reports have indicated that inadequately sterilized medical devices are one of the causes of a higher rate of healthcare-associated infections in developing countries. Steam sterilization (autoclaving) is the most widely used method for sterilization and is considered the most robust and cost-effective method for sterilization of medical devices. The effectiveness of steam sterilization can be measured using biological indicators. A literature search was undertaken to understand the effectiveness of autoclaving in sterilizing reusable medical devices in healthcare facilities across the globe. Studies using biological indicators for measuring the effectiveness of autoclaving were obtained. Failures of steam sterilization practices were identified and discussed as a means of identifying factors that might be associated with the ineffectiveness of steam sterilization practices between different countries. The number of studies measuring the effectiveness of steam sterilization is small, and few evaluate the effectiveness of steam sterilization specifically in developing countries. There are fewer studies on higher level healthcare facilities than dental facilities. More evidence about the effectiveness of autoclaving in healthcare facilities is needed to draw firm conclusions, but the data suggest that there are inadequacies in autoclave procedures and operator education.


Sign in / Sign up

Export Citation Format

Share Document