compression device
Recently Published Documents


TOTAL DOCUMENTS

429
(FIVE YEARS 96)

H-INDEX

27
(FIVE YEARS 2)

Author(s):  
Giacomo Bianchi ◽  
Giovanni Concistrè ◽  
Anees Al Jabri ◽  
Cecilia Bianchi ◽  
Elisa Barberi ◽  
...  

Myocardial damage from external cardiac massage can occur with either manual massage or with an automatic external device. We report the case of a patient with an aortic valve bioprosthesis undergoing advanced resuscitation with an automated external device for out-of-hospital-cardiac arrest, in whom the prolonged compressions caused an aortic root dissection.


2021 ◽  
Author(s):  
Tian-Zong Huang ◽  
Suhn Yeop Kim

Abstract Background: Low back pain (LBP) is a very common symptom experienced by individuals across all age groups. Previous study established that using a device known as Active Therapeutic Movement version 2 (ATM®2) has been developed to improve pain and joint range of motion (ROM) in patients with LBP. However, no study has examined the physiological change in the muscle through ATM®2-based exercise thus far. This study aimed to determine the immediate effects of ATM®2 exercise on the contraction timing, back extension endurance, muscle fatigue, and trunk ROM of lumbar and lower limb muscles in healthy subjects.Methods: Thirty-six healthy subjects (mean age=23.16±2.3) volunteered to participate in this study. Subjects were instructed to perform ROM test using sit and reach test, back extensor endurance test using Biering-Sorensen test, erector spinae (ES), lumbar multifidus (LM) fatigue and onset time of Gluteus maximus (GM) in prone hip extension using electromyography before and after trunk flexion and extension isometric exercises.Results: The ROM in trunk flexion showed a significant increase by 7.9% after exercise compared to that before exercise (p<0.05). Relative GM contraction onset timing significantly decreased after exercise (p<0.05). The result of the Sorensen test after exercise showed a trend of increase in duration time. Muscle fatigue in the LM, however, showed a significant increase (p<0.05), whereas muscle fatigue in the ES was reduced without statistical significance.Conclusions: The results base on this study showed a significant increase in the trunk ROM after trunk flexion and extension isometric exercise using an external compression device, while the relative contraction onset timing in the GM significantly reduced. Furthermore, the muscle endurance test after exercise showed a trend of increase in the duration time with a decreasing trend in muscle fatigue in the ES. Exercise based on ATM®2 is an effective exercise protocol with an effect on biomechanics of healthy subjects. This exercise may be suitable in clinical practice for patients with LBP, for which long-term effects can be expected.


2021 ◽  
pp. 028418512110681
Author(s):  
Jarruwat Charoensuk ◽  
Jiraporn Laothamatas ◽  
Witaya Sungkarat ◽  
Ladawan Worapruekjaru ◽  
Boonthida Hooncharoen ◽  
...  

Background There are no studies comparing the morphologic changes of lumbar spines between supine axial-loaded and 90° standing magnetic resonance imaging (MRI) examinations of patients with spinal stenosis. Purpose To determine whether axial-loaded MRI using a compression device demonstrated similar morphology of intervertebral disc, dural sac, and spinal curvature as those detected by 90° standing MRI in individuals with suspected spinal stenosis. Material and Methods A total of 54 individuals suspected of having spinal stenosis underwent both axial-loaded and standing MRI studies. The outcome measures included seven radiologic parameters of the lumbar spine: measures of the intervertebral disc (i.e. cross-sectional area [DA], disc height [DH], and anteroposterior distance [DAP]), dural sac (cross-sectional area [DCSA]), spinal curvature (i.e. lumbar lordosis [LL] and L1-L3-L5 angle [LA]), and total lumbar spine height (LH). Results For agreement between the two methods, intraclass correlation coefficient (ICC) ≥ 0.8 was found for all seven radiologic parameters. Supine axial-loaded MRI underestimated LL but remained correlated (ICC = 0.83) with standing MRI. Minor differences between the two methods (≤5.0%) were observed in DA, DCSA, DAP, LA, and LH, while a major difference was observed in LL (8.1%). Conclusion Using a compression device with the conventional supine MRI to simulate weight-bearing on the lumbar spine generated MRI morphology, which was strongly correlated with those from a standing MRI.


2021 ◽  
Vol 9 (4) ◽  
pp. 21-25
Author(s):  
Oksana Osipova ◽  
Yuliya Matvienko

The article analyzes the data obtained during soil testing in the ASIS-1 measuring and computational complex, the GT 1.3.1-05 triaxial compression device, conclusions are drawn about the possibility of determining the structural strength of soils in this device, graphic results are analyzed, and conclusions are drawn.


2021 ◽  
Vol 22 (21) ◽  
pp. 11331
Author(s):  
Md. Arafat Kabir ◽  
Akihiro Hirakawa ◽  
Bowen Zhu ◽  
Kenji Yokozeki ◽  
Mamata Shakya ◽  
...  

Concentrated growth factor (CGF) is 100% blood-derived, cross-linked fibrin glue with platelets and growth factors. Human CGF clot is transformed into membrane by a compression device, which has been widely used clinically. However, the mechanical properties of the CGF membranes have not been well characterized. The aims of this study were to measure the tensile strength of human CGF membrane and observe its behavior as a scaffold of BMP-2 in ectopic site over the skull. The tensile test of the full length was performed at the speed of 2mm/min. The CGF membrane (5 × 5 × 2 mm3) or the CGF/BMP-2 (1.0 μg) membrane was grafted onto the skull periosteum of nude mice (5-week-old, male), and harvested at 14 days after the graft. The appearance and size of the CGF membranes were almost same for 7 days by soaking at 4 °C in saline. The average values of the tensile strength at 0 day and 7 days were 0.24 MPa and 0.26 MPa, respectively. No significant differences of both the tensile strength and the elastic modulus were found among 0, 1, 3, and 7 days. Supra-periosteal bone induction was found at 14 days in the CGF/BMP-2, while the CGF alone did not induce bone. These results demonstrated that human CGF membrane could become a short-term, sticky fibrin scaffold for BMP-2, and might be preserved as auto-membranes for wound protection after the surgery.


2021 ◽  
Vol 14 (10) ◽  
pp. e245251
Author(s):  
Nasir Rahman ◽  
Ihsan Ullah ◽  
Awais Farhad ◽  
Ghufran Adnan

Conventional radial access has become the default access for coronary angiography. Sometime, it is difficult to take a conventional radial access, especially in patients having severe arthropathies leading to limited wrist joint mobility. In such scenarios, distal transradial access (dTRA) can be adopted. We describe a case of an elderly male patient having rheumatoid arthritis with arthropathies. He presented to us with unstable angina; coronary angiogram was advised for ischaemia assessment. Right dTRA was adopted due to severe joint deformity at wrist joint, limiting joint extension. A successful coronary angiogram was performed via the right dTRA without major discomfort and complications. Haemostasis was secured with TR band radial artery compression device. In this case report, we have evaluated the importance of practising dTRA in a patient with severe arthropathies.


Sign in / Sign up

Export Citation Format

Share Document